Noncontact Voltage Measurement System for Low-Voltage Power Line

被引:0
|
作者
Su, Huafeng [1 ]
Li, Haojun [1 ]
Liang, Weihao [1 ]
Shen, Chaolan [2 ]
Xu, Zheng [2 ]
机构
[1] Guangdong Power Grid Co Ltd, Dongguan Power Supply Bur, Dongguan 523120, Peoples R China
[2] Chongqing Univ, Sch Elect Engn, Chongqing 400044, Peoples R China
来源
关键词
All Open Access; Gold;
D O I
10.2528/PIERM23091304
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As one of the most basic electric quantities in a power system, voltage plays an important role in many fields such as condition monitoring and fault diagnosis. The construction and development of the smart grid cannot be separated from the reform and progress of the advanced sensing and measurement technology. Noncontact voltage measurement technology, as one of the important technologies, has many advantages such as no electrical contact, low insulation requirements, easy installation, and great potential in improving the panoramic perception ability of the power system. In this paper, a noncontact measurement method of the power line voltage based on capacitive coupling principle is proposed, which realizes the reliable measurement of the line voltage waveform. First, the principle of the noncontact voltage measurement method is introduced, which mainly includes self -calibration and online measurement of the sensor. The high -frequency voltage signal is injected into the capacitive coupling network of the sensor to implement the self -calibration of the sensor. Then, the digital integration method is used to integrate the output signal of the sensor to measure the line voltage waveform. Second, the noncontact voltage sensor prototype and signal processing circuit are designed. Finally, the test platform of the line voltage measurement is built, and the measurement test of 220 V/50 Hz line voltage waveform is carried out. The test results show the relative amplitude error of the voltage measured by the sensor is less than 2.5%, the maximum phase error less than 2(degrees) at 50 Hz, and the linearity better than 0.5%. The frequency response experiment shows that the system has almost constant gain in the frequency range of 50-1800 Hz, and the phase error reaches a maximum of 2.8(degrees) at a frequency of 1800 Hz.
引用
下载
收藏
页码:117 / 125
页数:9
相关论文
共 50 条
  • [1] A Noncontact Voltage Measurement System for Power-Line Voltage Waveforms
    Haberman, Marcelo A.
    Spinelli, Enrique M.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (06) : 2790 - 2797
  • [2] Low-voltage Power Line Broadband Communication System
    Du Peidong
    Wang Weizhou
    Liu Fuchao
    Zheng Jingjing
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING AND INTELLIGENT SYSTEMS (ICMEIS 2015), 2015, 26 : 42 - 45
  • [3] Measurement of Power Quality in Low-Voltage Network
    Bodnar, Roman
    Otcenasova, Alena
    Regula, Michal
    Szabo, Dominik
    2014 ELEKTRO, 2014, : 262 - 267
  • [4] Low-Voltage Power Line Communication System Based on DSP Technology
    Tie Weihao
    Wang Wenli
    Lu Can
    He Pengjun
    2011 3RD WORLD CONGRESS IN APPLIED COMPUTING, COMPUTER SCIENCE, AND COMPUTER ENGINEERING (ACC 2011), VOL 1, 2011, 1 : 504 - +
  • [5] Communication reliability design of low-voltage power line communication system
    Wang, QR
    Gong, SW
    2003 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS, VOLS 1-5, CONFERENCE PROCEEDINGS, 2003, : 4040 - 4044
  • [6] Channel estimation for OFDM system in low-voltage power line communication
    Geng, X
    Xie, ZY
    ICEMI 2005: CONFERENCE PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL 3, 2005, : 239 - 245
  • [7] Research on Noncontact Voltage Measurement Method for Three-Phase Busbar of Low-Voltage Distribution Cabinets
    Shen, Chaolan
    Liu, Xiaohu
    Jin, Ke
    Xu, Zheng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 13
  • [8] Research on Noncontact Voltage Measurement Method for Three-Phase Busbar of Low-Voltage Distribution Cabinets
    Shen, Chaolan
    Liu, Xiaohu
    Jin, Ke
    Xu, Zheng
    IEEE Transactions on Instrumentation and Measurement, 2024, 73 : 1 - 13
  • [9] Power Line Communications for Low-Voltage Power Grid Tomography
    Ahmed, Mohamed O.
    Lampe, Lutz
    IEEE TRANSACTIONS ON COMMUNICATIONS, 2013, 61 (12) : 5163 - 5175
  • [10] RESEARCH ON THE CHANNEL CHARACTERISTICS OF LOW-VOLTAGE POWER LINE
    Wang, Yongjian
    Song, Lizhong
    Ye, Jiaxing
    Wang, Lijing
    2012 IEEE 2nd International Conference on Cloud Computing and Intelligent Systems (CCIS) Vols 1-3, 2012, : 846 - 849