Automated and subjective refraction with monofocal, multifocal, and EDOF intraocular lenses: review

被引:4
|
作者
Bellucci, Carlo [1 ]
Mora, Paolo [1 ]
Tedesco, Salvatore Antonio [1 ]
Gandolfi, Stefano [1 ]
Bellucci, Roberto [2 ]
机构
[1] Univ Hosp Parma, Ophthalmol Unit, Parma, Italy
[2] Vista Vis Clin, Verona, Italy
来源
关键词
EXTENDED DEPTH; AUTOREFRACTION; REPEATABILITY; AGREEMENT; IMPLANTATION; PERFORMANCE; ABERROMETRY; EXPERIENCE; VALIDITY; VISION;
D O I
10.1097/j.jcrs.0000000000001186
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Automated refraction (Scheiner principle) is universally used to start a visual examination. Although the results are reliable in eyes implanted with monofocal intraocular lenses (IOLs), they may be less precise with multifocal (mIOL) or extended depth-of- focus (EDOF) IOLs and can even indicate a refractive error that does not clinically exist. Autorefractor results with monofocal, multifocal, and EDOF IOLs were investigated through literature search analyzing the papers reporting the difference between automated and clinical refraction. The average difference ranged between -0.50 diopter (D) and -1.00 D with most mIOL and EDOF IOLs. The differences in astigmatism were generally much lower. Autorefractors using infrared light cannot measure eyes with high technology IOLs precisely because of the influence of the refractive or of the diffractive near add. The systematic error induced with some IOLs should be mentioned in the IOL label to prevent possible inappropriate refractive procedures to treat apparent myopia. Copyright (c) 2023 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:642 / 648
页数:7
相关论文
共 50 条
  • [1] Refraction and defocus curves in eyes with monofocal and multifocal intraocular lenses
    Rodriguez-Vallejo, Manuel
    Burguera, Noemi
    Rocha-de-Lossada, Carlos
    Aramberri, Jaime
    Fernandez, Joaquin
    [J]. JOURNAL OF OPTOMETRY, 2023, 16 (03) : 236 - 243
  • [2] Influence of astigmatism on multifocal and monofocal intraocular lenses
    Hayashi, K
    Hayashi, H
    Nakao, F
    Hayashi, F
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 130 (04) : 477 - 482
  • [4] Subjective photic phenomena with refractive multifocal and monofocal intraocular lenses -: Results of a multicenter questionnaire
    Häring, G
    Dick, HB
    Krummenauer, F
    Weissmantel, U
    Kröncke, W
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (02): : 245 - 249
  • [5] A Comparison Between Monofocal and Multifocal Intraocular Lenses in the Influence of Pupil Dilation on Target Postoperative Refraction
    Teshigawara, Takeshi
    Meguro, Akira
    Mizuki, Nobuhisa
    [J]. ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2020, 9 (05): : 420 - 425
  • [6] CONTRAST SENSITIVITY THROUGH MULTIFOCAL AND MONOFOCAL INTRAOCULAR LENSES
    AKUTSU, H
    LEGGE, GE
    SHOWALTER, M
    KIRBY, VM
    LINDSTROM, RL
    ZABEL, RW
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 799 - 799
  • [7] Optical performance of monofocal versus multifocal intraocular lenses
    Gatinel, Damien
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11): : 1817 - 1818
  • [8] Optimal target refraction for implantation of monofocal intraocular lenses
    Harris, William F.
    [J]. ACTA OPHTHALMOLOGICA, 2012, 90 (01) : E75 - E76
  • [9] Clinical Outcomes after Exchange of Diffractive Multifocal Intraocular Lenses with Monofocal Intraocular Lenses
    Im, Sang Eun
    Lee, Jungmin
    Lee, Sung Jin
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (09): : 768 - 776
  • [10] Comparison of Visual Performance of Multifocal Intraocular Lenses with Same Material Monofocal Intraocular Lenses
    Yamauchi, Tomofusa
    Tabuchi, Hitoshi
    Takase, Kosuke
    Ohsugi, Hideharu
    Ohara, Zaigen
    Kiuchi, Yoshiaki
    [J]. PLOS ONE, 2013, 8 (06):