Dual Option Microtia Clinic: A Comparison of Outcomes in Microtia Reconstruction Using Autologous Rib or Porous Polyethylene Implant

被引:1
|
作者
Kulich, Marta [1 ,2 ]
Patel, Vijay A. [3 ,4 ]
Rezvan, Panteha Hayati [5 ]
Osterbauer, Beth [1 ]
Kochhar, Amit [1 ]
Gomez, Gabriel [1 ,6 ]
机构
[1] Childrens Hosp Los Angeles, Dept Surg, Div Otolaryngol Head & Neck Surg, Los Angeles, CA USA
[2] Univ Southern Calif, Dept Otolaryngol Head & Neck Surg, Keck Sch Med, Los Angeles, CA USA
[3] Rady Childrens Hosp San Diego, Dept Otolaryngol, San Diego, CA USA
[4] Univ Calif San Diego, Dept Surg, Div Otolaryngol Head & Neck Surg, La Jolla, CA USA
[5] Childrens Hosp Los Angeles, Saban Res Inst, Biostat & Data Anal Core, Los Angeles, CA USA
[6] Childrens Hosp Los Angeles, Dept Surg, Div Otolaryngol Head & Neck Surg, 4650 Sunset Blvd MS 58, Los Angeles, CA 90027 USA
基金
美国国家卫生研究院;
关键词
EAR RECONSTRUCTION; CARTILAGE; FRAMEWORK; CHILDREN;
D O I
10.1089/fpsam.2022.0406
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Auricular reconstruction techniques most frequently utilize either autologous costal cartilage or alloplastic porous polyethylene (PPE) implant.Objectives: To compare the aesthetic outcomes, number of surgeries, and complications in children who underwent microtia reconstruction with either rib or PPE implant by blinded photograph review.Methods: This retrospective cohort study included consecutive pediatric patients who underwent auricular reconstruction with either autologous cartilage or PPE between November 2017 and February 2022. Blinded observers rated each postoperative ear through a web-based survey. Data on patient characteristics, operative time, length of admission, and complications were collected, bivariate analyses were performed using chi-square or Fisher's exact tests for categorical variables and Wilcoxon rank-sum test for continuous variables.Results: Forty-four ears were included, 28 of which (63.6%) were reconstructed with cartilage. Median patient age was 8 years (range 4-18 years) and 29 (65.9%) were male. The cartilage group had more surgeries (median 2.5 vs. 1.0, p < 0.001), and total operating time across all surgeries did not differ significantly.Conclusion: The two groups in our study had similar rates of complications and aesthetic scores, and aesthetic scores were worse for ears with wound complications requiring unplanned revisions.
引用
收藏
页码:290 / +
页数:7
相关论文
共 45 条
  • [1] Commentary on: Dual Option Microtia Clinic: A Comparison of Outcomes in Microtia Reconstruction Using Autologous Rib or Porous Polyethylene Implant by Kulich et al
    Sie, Kathleen
    Bhrany, Amit
    FACIAL PLASTIC SURGERY & AESTHETIC MEDICINE, 2023, 25 (04) : 296 - 297
  • [2] Comparison of Microtia Reconstruction Outcomes Using Rib Cartilage vs Porous Polyethylene Implant
    Constantine, Kristin K.
    Gilmore, Jim
    Lee, Kenneth
    Leach, Joseph, Jr.
    JAMA FACIAL PLASTIC SURGERY, 2014, 16 (04) : 240 - 244
  • [3] A Hybrid Auricular Framework of Autologous Rib Cartilage and a Porous Polyethylene Implant for Reconstruction of Congenital Microtia: A Modification of Nagata's Technique
    Ku, Peter K. M.
    Vlantis, Alexander C.
    Tong, Marcus C.
    Chan, Trevor T. T.
    Yeung, Zenon W. C.
    Cho, Ryan H. W.
    Hui, Thomas S. C.
    Ho, Osan Y. M.
    Leung, Iris O. S.
    Tsang, Willis S. S.
    Lai, Nelson K. L.
    Chang, Wai-tsz
    Abdullah, Victor
    van Hasselt, Andrew
    Tong, Michael C. F.
    FACIAL PLASTIC SURGERY & AESTHETIC MEDICINE, 2024, 26 (01) : 15 - 22
  • [4] The Challenges and Considerations with Autologous Rib Microtia Reconstruction
    Liu, Yi-Chun C.
    Mukerji, Shraddha
    Truong, Mai Thy
    FACIAL PLASTIC SURGERY, 2025, 41 (02) : 198 - 203
  • [5] Microtia Reconstruction Autologous Rib and Alloplast Techniques
    Cabin, Jonathan A.
    Bassiri-Tehrani, Michael
    Sclafani, Anthony P.
    Romo, Thomas, III
    FACIAL PLASTIC SURGERY CLINICS OF NORTH AMERICA, 2014, 22 (04) : 623 - +
  • [6] Pediatric Microtia Reconstruction with Autologous Rib: Personal Experience and Technique with 1000 Pediatric Patients with Microtia
    Bonilla, Arturo
    FACIAL PLASTIC SURGERY CLINICS OF NORTH AMERICA, 2018, 26 (01) : 57 - +
  • [7] Negative pressure manoeuvre in microtia reconstruction with autologous rib cartilage
    Bangun, Kristaninta
    Chen, Philip Kuo-Ting
    Goh, Raymond C. W.
    Lee, Hung-Yi
    Chen, Zung-Chung
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2010, 63 (08): : 1279 - 1282
  • [8] Porous Polyethylene Versus Autologous Costochondral Reconstruction for Microtia: Incidence and Analysis of Secondary Procedures
    Varagur, Kaamya
    Zubovic, Ema
    Skolnick, Gary B.
    Buss, Joanna
    Snyder-Warwick, Alison
    Reinisch, John
    Patel, Kamlesh B.
    CLEFT PALATE CRANIOFACIAL JOURNAL, 2024, 61 (03): : 365 - 372
  • [9] Aesthetic auricular reconstruction with autologous rib cartilage grafts in adult microtia patients
    Han, So-Eun
    Lim, So-Young
    Pyon, Jai-Kyung
    Bang, Sa-Ik
    Mun, Goo-Hyun
    Oh, Kap Sung
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2015, 68 (08): : 1085 - 1094
  • [10] Porous Polyethylene Implant and Rib Cartilage in Ear Reconstruction: A Comparison
    Hamzavi, Sasan
    FACIAL PLASTIC SURGERY, 2015, 31 (06) : 611 - 616