Investigation of Forces and Moments during Orthodontic Tooth Intrusion Using Robot Orthodontic Measurement and Simulation System (ROSS)

被引:1
|
作者
Seidel, Corinna L. [1 ]
Lipp, Julian [1 ]
Dotzer, Benedikt [1 ]
Janjic Rankovic, Mila [1 ]
Mertmann, Matthias [1 ]
Wichelhaus, Andrea [1 ]
Sabbagh, Hisham [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Orthodont & Dentofacial Orthoped, Goethestr 70, D-80336 Munich, Germany
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 12期
关键词
nickel-titanium; NiTi archwires; initial levelling and aligning; intrusion; intrusion steps; orthodontic materials; biomechanical orthodontic simulation; orthodontic tooth movement; force control;
D O I
10.3390/bioengineering10121356
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The Robot Orthodontic Measurement and Simulation System (ROSS) is a novel biomechanical, dynamic, self-regulating setup for the simulation of tooth movement. The intrusion of the front teeth with forces greater than 0.5 N poses a risk for orthodontic-induced inflammatory root resorption (OIIRR). The aim was to investigate forces and moments during simulated tooth intrusion using ROSS. Five specimens of sixteen unmodified NiTi archwires and seven NiTi archwires with intrusion steps from different manufacturers (Forestadent, Ormco, Dentsply Sirona) with a 0.012 ''/0.014 ''/0.016 '' wire dimension were tested. Overall, a higher wire dimension correlated with greater intrusive forces Fz (0.012 '': 0.561-0.690 N; 0.014 '': 0.996-1.321 N; 0.016 '': 1.44-2.254 N) and protruding moments Mx (0.012 '': -2.65 to -3.922 Nmm; 0.014 '': -4.753 to -7.384 Nmm; 0.016 '': -5.556 to -11.466 Nmm) during the simulated intrusion of a 1.6 mm-extruded upper incisor. However, the 'intrusion efficiency' parameter was greater for smaller wire dimensions. Modification with intrusion steps led to an overcompensation of the intrusion distance; however, it led to a severe increase in Fz and Mx, e.g., the Sentalloy 0.016 '' medium (Dentsply Sirona) exerted 2.891 N and -19.437 Nmm. To reduce the risk for OIIRR, 0.014 '' NiTi archwires can be applied for initial aligning (without vertical challenges), and intrusion steps for the vertical levelling of extruded teeth should be bent in the initial archwire, i.e., 0.012 '' NiTi.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Biomechanical simulation of forces and moments of initial orthodontic tooth movement in dependence on the used archwire system by ROSS (Robot Orthodontic Measurement & Simulation System)
    Dotzer, Benedikt
    Stocker, Thomas
    Wichelhaus, Andrea
    Rankovic, Mila Janjic
    Sabbagh, Hisham
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 144
  • [2] Biomechanical simulation of segmented intrusion of a mandibular canine using Robot Orthodontic Measurement & Simulation System (ROSS)
    Sabbagh, Hisham
    Dotzer, Benedikt
    Baumert, Uwe
    Hoetzel, Linus
    Seidel, Corinna Lesley
    Wichelhaus, Andrea
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 160
  • [3] Dynamic measurement of orthodontic force using a tooth movement simulation system based on a wax model
    Wu, Jianlei
    Liu, Yunfeng
    Wang, Dongcai
    Huang, Senda
    Zhang, Jianxing
    Chen, Jie
    Dong, Xingtao
    TECHNOLOGY AND HEALTH CARE, 2021, 29 (03) : 457 - 466
  • [4] Measurement of orthodontic forces using polymer PCF
    Milczewski, Maura S.
    Martelli, Cicero
    Canning, John
    Stevenson, Michael
    Simoes, Jose
    Kalinowski, Hypolito
    2007 THE JOINT INTERNATIONAL CONFERENCE ON OPTICAL INTERNET AND AUSTRALIAN CONFERENCE ON OPTICAL FIBRE TECHNOLOGY, 2007, : 151 - +
  • [5] Computational simulation of the tooth movement during the orthodontic treatment
    Soncini, M
    Pietrabissa, R
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING - 3, 2001, : 565 - 570
  • [6] MUSCULATURE, CYBERNETICS, AND A SYSTEM FOR MEASUREMENT OF BIOLOGICAL FORCES DURING ORTHODONTIC TREATMENT AND RETENTION
    JACOBS, RM
    AMERICAN JOURNAL OF ORTHODONTICS, 1970, 57 (01): : 75 - &
  • [7] Orthodontic System Modeled and Simulated with the Lingual Technique to Assess Tooth Forces
    Hazem, Abbas
    Marasescu, Felicia Ileana
    Tuculina, Mihaela Jana
    Popescu, Alexandru Dan
    Popa, Dragos Laurentiu
    Mihai, Lelia Laurenta
    Cumpata, Cristian Niky
    Iliescu, Alexandru
    Marasescu, Petre
    Dascalu, Ionela Teodora
    DIAGNOSTICS, 2024, 14 (11)
  • [8] MEASUREMENT OF TOOTH MOVEMENT DURING NORMAL ERUPTION AND DURING ORTHODONTIC TREATMENT
    ANDERSON, DJ
    RONNING, GA
    JOURNAL OF DENTAL RESEARCH, 1963, 42 (05) : 1113 - &
  • [9] Inverse kinematic modeling for simulation of initial tooth displacement responding to orthodontic forces
    Montero, ED
    Yashiro, K
    Takada, K
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 2738 - 2741
  • [10] Computer simulation of orthodontic tooth movement using FE analysis
    Hasegawa, Masakazu
    Adachi, Taiji
    Hojo, Masaki
    Takano-Yamamoto, Teruko
    INTERFACE ORAL HEALTH SCIENCE 2009, 2010, : 143 - +