An outbreak of septic arthritis after arthroscopic reconstruction of the anterior cruciate ligament

被引:0
|
作者
Evik, Guliz [1 ]
Turkmen, Gulcan [2 ]
Bozdag, Fatma [3 ]
Colak, Mehmet [4 ]
Ersoz, Gulden [5 ]
机构
[1] Mersin Univ, Dept Infect Dis, Fac Med, TR-33343 Mersin, Turkiye
[2] Mersin Univ Hosp, Dept Nursing, Mersin, Turkiye
[3] Mersin Univ, Dept Publ Hlth, Fac Med, Mersin, Turkiye
[4] Mersin Univ, Fac Med, Dept Orthopaed & Traumatol, Mersin, Turkiye
[5] Mersin Univ, Fac Med, Dept Infect Dis, Mersin, Turkiye
来源
关键词
Arthroscopic Surgery; Anterior Cruciate Ligament; Septic Arthritis; Outbreak; SURGICAL SITE INFECTIONS; MANAGEMENT; GRAFT;
D O I
10.4328/ACAM.21699
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: Acute septic arthritis after arthroscopic posterior cruciate ligament (PCL) reconstruction is uncommon but is a very critical complication. Properly sterilized surgical instruments are the most important step in preventing infection. After arthroscopic anterior cruciate ligament surgery, a cluster of 6 jointbursa infection cases was seen in our unit. The aim of this study was to determine the socio-demographic and clinical practices that may be associated with the development of infection in the surgical site after arthroscopic cruciate ligament surgery. Material and Methods: This was a cross-sectional study of SSIs developing after arthroscopic anterior cruciate ligament surgery in 2018 in a University Hospital. Environmental and surgical equipment samples were taken. ATP bioluminescence test was performed on these samples. When a high-risk status was detected, surveillance cultures were performed. Results: A total of 15 procedures meeting the inclusion and exclusion criteria were evaluated. Six patients were considered to have infections, while 9 were infection-free. An examination of the surgery lists showed that 6 of the 7 patients with infection represented the first arthroscopic procedure of the day. An inquiry regarding personnel of the surgery room showed that a newly appointed nurse made a modification in the decontamination procedure of the surgical equipment. Discussion: Incomplete sterilization of surgical equipment and environmental contamination can lead to serious infection.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Septic arthritis after Arthroscopic anterior cruciate ligament reconstruction
    Fong, SY
    Tan, JL
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2004, 33 (02) : 228 - 234
  • [2] Septic arthritis after arthroscopic anterior cruciate ligament reconstruction - Diagnosis and management
    Williams, RJ
    Laurencin, CT
    Warren, RF
    Speciale, AC
    Brause, BD
    OBrien, S
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1997, 25 (02): : 261 - 267
  • [3] Arthroscopic Irrigation and Debridement in the Treatment of Septic Arthritis After Anterior Cruciate Ligament Reconstruction
    Saper, Michael
    Stephenson, Kyle
    Heisey, Meredith
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (06): : 747 - 754
  • [4] Septic arthritis after Arthroscopic anterior Cruciate ligament reconstruction: A retrospective analysis of incidence, management and outcome
    Van Tongel, Alexander
    Stuyck, Jos
    Bellemans, Johan
    Vandenneucker, Hilde
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (07): : 1059 - 1063
  • [5] Management of septic arthritis after arthroscopic anterior cruciate ligament reconstruction using a standard surgical protocol
    Hantes, Michael E.
    Raoulis, Vasilios A.
    Doxariotis, Nikolaos
    Drakos, Athanasios
    Karachalios, Theofilos
    Malizos, Konstantinos N.
    KNEE, 2017, 24 (03): : 588 - 593
  • [6] Septic Arthritis After Arthroscopic Anterior Cruciate Ligament Reconstruction: Evaluation of an Arthroscopic Graft-Retaining Treatment Protocol
    Schuster, Philipp
    Schulz, Martin
    Immendoerfer, Micha
    Mayer, Philipp
    Schlumberger, Michael
    Richter, Joerg
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2015, 43 (12): : 3005 - 3012
  • [7] Outcomes of postoperative septic arthritis after anterior cruciate ligament reconstruction
    McAllister, DR
    Parker, RD
    Cooper, AE
    Recht, MP
    Abate, J
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (05): : 562 - 570
  • [8] Septic arthritis in postoperative anterior cruciate ligament reconstruction
    Indelli, PF
    Dillingham, M
    Fanton, G
    Schurman, DJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (398) : 182 - 188
  • [9] Septic Arthritis After Arthroscopic Anterior Cruciate Ligament Reconstruction: A Retrospective Analysis of Incidence, Presentation, Treatment, and Cause
    Wang, Cheng
    Ao, Yingfang
    Wang, Jianquan
    Hu, Yuelin
    Cui, Guoqing
    Yu, Jiakuo
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (03): : 243 - 249
  • [10] Infection After Arthroscopic Anterior Cruciate Ligament Reconstruction
    Kim, Seung-Ju
    Postigo, Ricardo
    Koo, Sowon
    Kim, Jong Hun
    ORTHOPEDICS, 2014, 37 (07) : 477 - 484