Comparison of In-Vivo and Ex-Vivo Ascending Aorta Elastic Properties through Automatic Deep Learning Segmentation of Cine-MRI and Biomechanical Testing

被引:5
|
作者
Markodimitrakis, Emmanouil [1 ]
Lin, Siyu [1 ]
Koutoulakis, Emmanouil [1 ]
Marin-Castrillon, Diana Marcela [1 ]
Saez, Francisco Aaron Tovar [1 ]
Leclerc, Sarah [1 ]
Bernard, Chloe [1 ,2 ]
Boucher, Arnaud [1 ]
Presles, Benoit [1 ]
Bouchot, Olivier [1 ,2 ]
Decourselle, Thomas [3 ]
Morgant, Marie-Catherine [1 ,2 ]
Lalande, Alain [1 ,4 ]
机构
[1] Univ Burgundy & Franche Comte, ImViA Lab, EA 7535, F-21000 Dijon, France
[2] Univ Hosp Dijon, Dept Cardio Vasc & Thorac Surg, F-21079 Dijon, France
[3] CASIS CArdiac Simulat & Imaging Software SAS, F-21800 Quetigny, France
[4] Univ Hosp Dijon, Dept Med Imaging, F-21079 Dijon, France
关键词
cine-MRI; deep learning segmentation; ascending aortic elasticity; young modulus; YOUNGS MODULUS; INTERNATIONAL REGISTRY; MECHANICAL-PROPERTIES; DISSECTION;
D O I
10.3390/jcm12020402
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Ascending aortic aneurysm is a pathology that is important to be supervised and treated. During the years the aorta dilates, it becomes stiff, and its elastic properties decrease. In some cases, the aortic wall can rupture leading to aortic dissection with a high mortality rate. The main reference standard to measure when the patient needs to undertake surgery is the aortic diameter. However, the aortic diameter was shown not to be sufficient to predict aortic dissection, implying other characteristics should be considered. Therefore, the main objective of this work is to assess in-vivo the elastic properties of four different quadrants of the ascending aorta and compare the results with equivalent properties obtained ex-vivo. The database consists of 73 cine-MRI sequences of thoracic aorta acquired in axial orientation at the level of the pulmonary trunk. All the patients have dilated aorta and surgery is required. The exams were acquired just prior to surgery, each consisting of 30 slices on average across the cardiac cycle. Multiple deep learning architectures have been explored with different hyperparameters and settings to automatically segment the contour of the aorta on each image and then automatically calculate the aortic compliance. A semantic segmentation U-Net network outperforms the rest explored networks with a Dice score of 98.09% (+/- 0.96%) and a Hausdorff distance of 4.88 mm (+/- 1.70 mm). Local aortic compliance and local aortic wall strain were calculated from the segmented surfaces for each quadrant and then compared with elastic properties obtained ex-vivo. Good agreement was observed between Young's modulus and in-vivo strain. Our results suggest that the lateral and posterior quadrants are the stiffest. In contrast, the medial and anterior quadrants have the lowest aortic stiffness. The in-vivo stiffness tendency agrees with the values obtained ex-vivo. We can conclude that our automatic segmentation method is robust and compatible with clinical practice (thanks to a graphical user interface), while the in-vivo elastic properties are reliable and compatible with the ex-vivo ones.
引用
收藏
页数:15
相关论文
共 2 条
  • [1] Comparison of two techniques (in vivo and ex-vivo) for evaluating the elastic properties of the ascending aorta: Prospective cohort study
    Morgant, Marie-Catherine
    Lin, Siyu
    Marin-Castrillon, Diana
    Bernard, Chloe
    Laubriet, Aline
    Cochet, Alexandre
    Lalande, Alain
    Bouchot, Olivier
    PLOS ONE, 2021, 16 (09):
  • [2] Implementing a deep learning model for automatic tongue tumour segmentation in ex-vivo 3-dimensional ultrasound volumes
    Bekedam, N. M.
    Idzerda, L. H. W.
    van Alphen, M. J. A.
    van Veen, R. L. P.
    Karssemakers, L. H. E.
    Karakullukcu, M. B.
    Smeele, L. E.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2024, 62 (03): : 284 - 289