Gross failure rates and failure modes for a commercial AI-based auto-segmentation algorithm in head and neck cancer patients

被引:2
|
作者
Temple, Simon W. P. [1 ]
Rowbottom, Carl G. [1 ,2 ]
机构
[1] Clatterbridge Canc Ctr NHS Fdn Trust, Med Phys Dept, Liverpool, England
[2] Univ Liverpool, Dept Phys, Liverpool, England
来源
关键词
auto-segmentation; deep learning; failure modes; INTEROBSERVER VARIABILITY; DELINEATION; ORGANS; RISK; IMPLEMENTATION; ONCOLOGY; QUALITY;
D O I
10.1002/acm2.14273
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeArtificial intelligence (AI) based commercial software can be used to automatically delineate organs at risk (OAR), with potential for efficiency savings in the radiotherapy treatment planning pathway, and reduction of inter- and intra-observer variability. There has been little research investigating gross failure rates and failure modes of such systems.Method50 head and neck (H&N) patient data sets with "gold standard" contours were compared to AI-generated contours to produce expected mean and standard deviation values for the Dice Similarity Coefficient (DSC), for four common H&N OARs (brainstem, mandible, left and right parotid). An AI-based commercial system was applied to 500 H&N patients. AI-generated contours were compared to manual contours, outlined by an expert human, and a gross failure was set at three standard deviations below the expected mean DSC. Failures were inspected to assess reason for failure of the AI-based system with failures relating to suboptimal manual contouring censored. True failures were classified into 4 sub-types (setup position, anatomy, image artefacts and unknown).ResultsThere were 24 true failures of the AI-based commercial software, a gross failure rate of 1.2%. Fifteen failures were due to patient anatomy, four were due to dental image artefacts, three were due to patient position and two were unknown. True failure rates by OAR were 0.4% (brainstem), 2.2% (mandible), 1.4% (left parotid) and 0.8% (right parotid).ConclusionTrue failures of the AI-based system were predominantly associated with a non-standard element within the CT scan. It is likely that these non-standard elements were the reason for the gross failure, and suggests that patient datasets used to train the AI model did not contain sufficient heterogeneity of data. Regardless of the reasons for failure, the true failure rate for the AI-based system in the H&N region for the OARs investigated was low (similar to 1%).
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Clinical Implementation of AI-Based Auto-Segmentation
    Kisling, Kelly
    Yang, J.
    Sharp, G.
    Elguindi, S.
    MEDICAL PHYSICS, 2022, 49 (06) : E487 - E488
  • [2] Evaluation of atlas based auto-segmentation tool for head and neck cancer patients
    Kuddu, M.
    Kanger, M.
    Zolotuhhin, D.
    Kolk, K.
    Tiigi, R.
    Bisheva, N.
    Gershkevitsh, E.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S27 - S27
  • [3] Clinical Evaluation of Commercial Atlas-Based Auto-Segmentation in the Head and Neck Region
    Lee, Hyothaek
    Lee, Eungman
    Kim, Nalee
    Kim, Joo Ho
    Park, Kwangwoo
    Lee, Ho
    Chun, Jaehee
    Shin, Jae-ik
    Chang, Jee Suk
    Kim, Jin Sung
    FRONTIERS IN ONCOLOGY, 2019, 9
  • [4] AUTO-SEGMENTATION OF HEAD AND NECK CANCER USING TEXTURAL FEATURES
    Hollensen, C.
    Jorgensen, P. S.
    Hojgaard, L.
    Specht, L.
    Larsen, R.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S172 - S172
  • [5] Performance Evaluation of AI-Based Automatic Segmentation Modules for Head and Neck Cancer Patients
    Liao, Y.
    Injerd, R.
    Tolekidis, G.
    Joshi, N.
    Turian, J.
    MEDICAL PHYSICS, 2022, 49 (06) : E671 - E671
  • [6] Evaluation of a Commercial Auto-segmentation Tool in the Outlining of Node Stations in Head and Neck Cancer (HNCa)
    Ingle, C. J.
    James, H. V.
    Parker, R. A.
    Scrase, C. D.
    CLINICAL ONCOLOGY, 2011, 23 (03) : S52 - S52
  • [7] AI-based MRI auto-segmentation of brain tumor in rodents, a multicenter study
    Wang, Shuncong
    Pang, Xin
    de Keyzer, Frederik
    Feng, Yuanbo
    Swinnen, Johan V. V.
    Yu, Jie
    Ni, Yicheng
    ACTA NEUROPATHOLOGICA COMMUNICATIONS, 2023, 11 (01)
  • [8] AI-based MRI auto-segmentation of brain tumor in rodents, a multicenter study
    Shuncong Wang
    Xin Pang
    Frederik de Keyzer
    Yuanbo Feng
    Johan V. Swinnen
    Jie Yu
    Yicheng Ni
    Acta Neuropathologica Communications, 11
  • [9] EVALUATION OF A COMMERCIAL AUTO-SEGMENTATION TOOL IN THE OUTLINING OF LYMPH NODES & ORGANS AT RISK IN HEAD AND NECK CANCER
    Ingle, C.
    Parker, R.
    James, H.
    Scrase, C. D.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S578 - S578
  • [10] Validation of a Commercial Artificial Intelligence Auto-Segmentation System for Head and Neck Treatment Site
    Tsai, P.
    Huang, S.
    Press, R.
    Shim, A.
    Apinorasethkul, C.
    Chen, C.
    Hu, L.
    Jang, E.
    Lin, H.
    MEDICAL PHYSICS, 2022, 49 (06) : E297 - E297