Drop-In Replacement of R134a in a Household Refrigerator with Low-GWP Refrigerants R513A, R516A, and R1234ze(E)

被引:4
|
作者
Belman-Flores, Juan M. [1 ]
Heredia-Aricapa, Yonathan [1 ]
Garcia-Pabon, Juan J. [2 ]
Perez-Garcia, Vicente [1 ]
Perez-Reguera, Cesar G. [3 ]
机构
[1] Univ Guanajuato, Dept Mech Engn, Engn Div, IRSE Res Grp, Campus Irapuato Salamanca, Salamanca 36885, Mexico
[2] Fed Univ Itajuba UNIFEI, Inst Mech Engn, Ave BPS, BR-37500903 Itajuba, Brazil
[3] Mabe TyP, Acceso B406,Parque Ind Jurica, Jurica 76120, Mexico
关键词
domestic refrigerator; drop-in; energy analysis; low GWP; R516A; R1234YF;
D O I
10.3390/en16083422
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study proposes the experimental evaluation of alternative refrigerants with low global warming potentials (GWPs) such as R1234ze(E), R513A, and the mixture R516A as a drop-in replacement for R134a in a domestic refrigerator with a volumetric capacity of 513 L. Initially, the optimal charge for each refrigerant was defined based on the minimum energy consumption of the refrigerator, then the thermal and energy performance of the refrigerator was evaluated. Finally, a total equivalent warming impact analysis (TEWI) was performed. The main results indicated that the optimal charge of the alternative refrigerants was below that corresponding to R134a (105 g), of which R516A (86 g) presented the greatest charge reduction. Regarding the average temperature of the refrigerator compartments, very adequate thermal conditions were observed; thus, the alternative refrigerants showed very similar conditions to R134a. For the coefficient of performance (COP) and considering R134a as a reference, it was observed that R513A presented the greatest reduction of around 28%, while R1234ze(E) showed an increase of 13% in relation to R134a. Finally, the TEWI analysis showed R1234ze(E) as the refrigerant with the least impact.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Comparative performance of low-GWP refrigerants R513A and R1234ze(E) in flow boiling within smooth and microfin tubes
    Oudah, Mahmood Hasan
    Yasser, Zahraa Kareem
    APPLIED THERMAL ENGINEERING, 2025, 263
  • [2] Drop-in analysis of R450A and R513A as low-GWP alternatives to R134a in a water-to-water heat pump
    Molinaroli, Luca
    Lucchini, Andrea
    Colombo, Luigi Pietro Maria
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 135 : 139 - 147
  • [3] Drop-in analysis of R450A and R513A as low-GWP alternatives to R134a in a water-to-water heat pump
    Molinaroli, Luca
    Lucchini, Andrea
    Colombo, Luigi Pietro Maria
    International Journal of Refrigeration, 2022, 135 : 139 - 147
  • [4] Experimental study on R1234yf/R134a mixture (R513A) as R134a replacement in a domestic refrigerator
    Yang, Meng
    Zhang, Hua
    Meng, Zhaofeng
    Qin, Yanbin
    APPLIED THERMAL ENGINEERING, 2019, 146 : 540 - 547
  • [5] Experimental energy evaluation of R516A and R513A as replacement of R134a in refrigeration and air conditioning modes
    Mendez-Mendez, D.
    Perez-Garcia, V.
    Morales-Fuentes, A.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 154 : 73 - 83
  • [6] Experimental study of an R1234ze(E)/R134a mixture (R450A) as R134a replacement
    Mota-Babiloni, Adrian
    Navarro-Esbri, Joaquin
    Barragan-Cervera, Angel
    Moles, Francisco
    Peris, Bernardo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 51 : 52 - 58
  • [7] Experimental evaluation of low-GWP refrigerants R513A, R1234yf and R436A as alternatives for R134a in a cascade refrigeration cycle with R744
    Ojeda, Frank William Adolfo Blanco
    Queiroz, Marcus Vinicius Almeida
    Pico, David Fernando Marcucci
    Parise, Jose Alberto dos Reis
    Bandarra Filho, Enio Pedone
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 144 : 175 - 187
  • [8] Low GWP refrigerants R1234ze(E) and R1234ze(Z) for high temperature heat pumps
    Fukuda, Sho
    Kondou, Chieko
    Takata, Nobuo
    Koyama, Shigeru
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2014, 40 : 161 - 173
  • [9] R1234yf and R1234ze(E) as low-GWP refrigerants for residential heat pump water heaters
    Nawaz, Kashif
    Shen, Bo
    Elatar, Ahmed
    Baxter, Van
    Abdelaziz, Omar
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 82 : 348 - 365
  • [10] Experimental evaluation of R513A as a low GWP refrigerant to replace R134a in a domestic refrigerator
    Belman-Flores, J. M.
    Heredia-Aricapa, Y.
    Pardo-Cely, D.
    Rodriguez-Valderrama, D. A.
    De Alba-Rosano, M.
    Silva-Romero, J. C.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 142 : 148 - 155