Subacromial space measured by ultrasound imaging in asymptomatic subjects and patients with subacromial shoulder pain: an inter-rater reliability study

被引:4
|
作者
Cavaggion, Claudia [1 ]
Navarro-Ledesma, Santiago [2 ]
Luque-Suarez, Alejandro [3 ,4 ]
Juul-Kristensen, Birgit [5 ]
Voogt, Lennard [6 ,7 ,8 ]
Struyf, Filip [1 ]
机构
[1] Univ Antwerp, Fac Med & Hlth Sci, Dept Rehabil Sci & Physiotherapy REVAKI, Res Grp MOVANT, Univ Pl 1, B-2610 Antwerp, Belgium
[2] Univ Granada, Fac Hlth Sci, Dept Physiotherapy, Campus Melilla, Melilla, Spain
[3] Univ Malaga, Dept Physiotherapy, Malaga, Spain
[4] Inst Invest Biomed Malaga IBIMA, Malaga, Spain
[5] Univ Southern Denmark, Dept Sports Sci & Clin Biomech, Odense, Denmark
[6] Rotterdam Univ Appl Sci, Dept Phys Therapy Studies, Rotterdam, Netherlands
[7] Rotterdam Univ Appl Sci, Res Ctr Hlth Care Innovat, Rotterdam, Netherlands
[8] Vrije Univ Brussel, Fac Phys Educ & Physiotherapy, Dept Physiotherapy Human Physiol & Anat, Pain Mot Res Grp PAIN, Brussels, Belgium
关键词
Acromiohumeral distance; supraspinatus tendon; reproducibility of results; shoulder pain; ultrasonography; SUPRASPINATUS TENDON THICKNESS; ROTATOR CUFF TENDINOPATHY; ACROMIOHUMERAL DISTANCE; REHABILITATION; AGREEMENT;
D O I
10.1080/09593985.2022.2072251
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background Acromiohumeral distance (AHD) and supraspinatus tendon thickness (STT) measured by ultrasound (US) can be combined in the occupation ratio (OR). Inter-rater reliability on these subacromial measures depends on the US experience of raters and on the subject status, differing between asymptomatic or patients with subacromial shoulder pain (SSP). Objective To evaluate inter-rater reliability between two raters with different US experience (experienced examiner and novice examiner). Methods In total, 20 asymptomatic subjects (controls) and 21 patients with SSP were examined on one shoulder. Inter-rater reliability was evaluated with intraclass correlation coefficient (ICC). Results ICC for controls was good for AHD at rest and at 60 degrees (0.76-0.77), moderate for STT and AHD at 60 degrees with weights (0.53-0.72), while OR was poorly reliable (below 0.44). ICC for SSP was moderate for AHD at rest and at 60 degrees, STT, OR at rest and at 60 degrees (0.52-0.74) and poor for AHD at 60 degrees with weights and OR at 60 degrees with weights (0.33-0.36). Bland-Altman plots showed systematic bias. Conclusion Inter-rater reliability varied largely from poor to good between two examiners with different US experience. Clinicians might use the US as additional tool for detecting the subacromial structures, but a structured training including also symptomatic subjects is suggested. Researchers may further investigate the OR in matched case-control studies, and an overall agreement phase is recommended before starting the inter-rater reliability phase.
引用
下载
收藏
页码:2196 / 2207
页数:12
相关论文
共 50 条
  • [1] Intra-rater and inter-rater reliability of the standardized ultrasound protocol for assessing subacromial structures
    Hougs Kjaer, Birgitte
    Ellegaard, Karen
    Wieland, Ina
    Warming, Susan
    Juul-Kristensen, Birgit
    PHYSIOTHERAPY THEORY AND PRACTICE, 2017, 33 (05) : 398 - 409
  • [2] Ultrasound imaging in patients with hip pain and suspected hip osteoarthritis: an inter-rater and intra-rater reliability study
    Clausen, Stine
    Kjaer, Soren
    Fredberg, Ulrich
    Terslev, Lene
    Hartvigsen, Jan
    Arnbak, Bodil
    BMJ OPEN, 2020, 10 (11):
  • [3] Reliability of point-of-care shoulder ultrasound measurements for subacromial impingement in asymptomatic participants
    Yuan, Xiaoning
    Lowder, Ryan
    Aviles-Wetherell, Kathelynn
    Skroce, Christian
    Yao, Katherine V.
    Soo Hoo, Jennifer
    FRONTIERS IN REHABILITATION SCIENCES, 2022, 3
  • [4] INTRA- AND INTER-RATER RELIABILITY OF HYOID DISPLACEMENT MEASURED BY ULTRASOUND
    Macrae, Phoebe
    Huckabee, M.
    Doeltgen, S.
    Jones, R.
    DYSPHAGIA, 2009, 24 (04) : 482 - 483
  • [5] INTER-RATER RELIABILITY OF LUNG ULTRASOUND INTERPRETATION IN HD PATIENTS
    Yarmey, Erik
    Shofer, Frances S.
    Dean, Anthony J.
    Panebianco, Nova
    Reisinger, Nathaniel
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2019, 73 (05) : 723 - 723
  • [6] LEARNING AND INTER-RATER RELIABILITY STUDY OF THREE AND FOUR DIMENSIONAL TRANSPERINEAL ULTRASOUND IMAGING
    Richter, F.
    Staer-Jensen, J.
    Hoff, Brakken, I
    Bo, K.
    Ellstrom, Engh M.
    NEUROUROLOGY AND URODYNAMICS, 2011, 30 (06) : 1106 - 1107
  • [7] Inter-rater reliability of McKenzie assessment in patients with neck pain
    Dionne, Carol P.
    Bybee, Ronald F.
    Tomaka, Joe
    PHYSIOTHERAPY, 2006, 92 (02) : 75 - 82
  • [8] Doppler compression ultrasound of the lower extremities in ICU patients: An inter-rater reliability study
    Cook, DJ
    Medic, A
    Andrews, J
    Schiff, D
    Dobranowski, J
    Bates, S
    McDonald, E
    Landry, F
    Crowther, M
    CRITICAL CARE MEDICINE, 2002, 30 (12) : A77 - A77
  • [9] INTER-RATER RELIABILITY AND VALIDITY OF ULTRASOUND IMAGING FOR FEATURES OF OSTEOARTHRITIS IN THE KNEE IN THE COMMUNITY
    Abraham, Ajay
    Goff, Iain
    Pearce, Mark S.
    Francis, Roger M.
    Birrell, Fraser
    RHEUMATOLOGY, 2010, 49 : I33 - I33
  • [10] Inter-Rater Reliability of Ultrasound Imaging of the Trunk Musculature Among Novice Raters
    Teyhen, Deydre S.
    George, Steven Z.
    Dugan, Jessica L.
    Williamson, Jared
    Neilson, Brett D.
    Childs, John D.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (03) : 347 - 356