Detection of paroxysmal atrial fibrillation preceding persistent atrial fibrillation in a horse using an implantable loop recorder with remote monitoring

被引:2
|
作者
Vernemmen, I. [1 ]
Van Steenkiste, G. [1 ]
Decloedt, A. [1 ]
Meert, H. [2 ]
Walser, U. [2 ]
van Loon, G. [1 ]
机构
[1] Univ Ghent, Dept Internal Med Reprod & Populat Med, Equine Cardioteam Ghent, Salisburylaan 133, B-9820 Merelbeke, Belgium
[2] Biotronik Belgium, Medialaan 36, B-1800 Vilvoorde, Belgium
关键词
Insertable cardiac monitor; Event recorder; Home monitoring; Arrhythmia; Telemetry; MANAGEMENT;
D O I
10.1016/j.jvc.2024.02.002
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Implantable loop recorders (ILRs) are increasingly used in equine cardiology to detect arrhythmias in the context of collapse, poor performance or monitoring for recurrence of atrial fibrillation (AF). However to date, the ILR has never been reported to be used with a remote monitoring functionality in horses, therefore the arrhythmia is only discovered when a clinician interrogates the ILR using dedicated equipment, which might delay diagnosis and intervention. This case report describes the use of an ILR with remote monitoring functionality in a horse with recurrent AF. The remote monitoring consisted of a transmission device located in the stable allowing daily transmission of arrhythmia recordings and functioning messages to an online server, available for the clinician to evaluate without specialised equipment. The ILR detected an episode of paroxysmal AF approximately 3 months after implantation. Seven months after implantation, initiation of persistent AF was seen on an episode misclassified by the ILR as bradycardia, and the horse was retired. This report shows the feasibility and benefits of remote monitoring for ILRs in horses, but also the shortcomings of current algorithms to interpret the equine electrocardiogram. (c) 2024 Elsevier B.V. All rights reserved.
引用
收藏
页码:19 / 27
页数:9
相关论文
共 50 条
  • [1] Detection of paroxysmal atrial fibrillation by implantable loop recorder in cryptogenic stroke
    Giobbe, D.
    Balducci, A.
    Paglia, G.
    Giobbe, M. L.
    Budano, C.
    Alunni, G. L.
    Giorgi, M.
    EUROPEAN JOURNAL OF NEUROLOGY, 2016, 23 : 138 - 138
  • [2] PAROXYSMAL ATRIAL FIBRILLATION PICTURED BY IMPLANTABLE DEVICES WITH REMOTE MONITORING
    Varma, N.
    JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 2011, 65 : A415 - A415
  • [3] Electrocardiographic events preceding onset of atrial fibrillation: Insights gained using an implantable loop recorder
    Schwartzman, D
    Blagev, DP
    Brown, ML
    Mehra, R
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (03) : 243 - 246
  • [4] Electrocardiographic events preceding the onset of atrial fibrillation: Insights gained using an implantable loop recorder
    Schwartzman, DS
    Brown, ML
    Fitts, SM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 130A - 130A
  • [5] ROLE OF IMPLANTABLE LOOP RECORDER IN THE MANAGEMENT OF ATRIAL FIBRILLATION
    Thapamagar, S. B.
    Rakhshan, E.
    Sooklal, S.
    Mascarenhas, D. A.
    CARDIOLOGY, 2013, 125 : 333 - 333
  • [6] Race disparities in atrial fibrillation detection using implantable loop recorder for cryptogenic stroke
    Aslam, F.
    Al-Sadawi, M.
    Gore, A.
    Ijaz, H.
    Dhar, K.
    Dhaliwal, A.
    Singh, A.
    EUROPEAN HEART JOURNAL, 2022, 43 : 409 - 409
  • [7] Performance of an External Transtelephonic Loop Recorder for Automated Detection of Paroxysmal Atrial Fibrillation
    Velthuis, Bob Oude
    Bos, Jorieke
    Kraaier, Karin
    Stevenhagen, Jeroen
    van Opstal, Jurren M.
    van der Palen, Job
    Scholten, Marcoen F.
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2013, 18 (06) : 564 - 570
  • [8] Utility and limitations of long-term monitoring of atrial fibrillation using an implantable loop recorder
    Lee, Randall
    Mittal, Suneet
    HEART RHYTHM, 2018, 15 (02) : 287 - 295
  • [9] Long-term monitoring with an implantable loop recorder detects multiple episodes of paroxysmal atrial fibrillation after electrical cardioversion in a Warmblood horse
    Kjeldsen, Sofie Troest
    Jensen, Maria
    Sorensen, Carina Thermann
    Hopster-Iversen, Charlotte
    Nissen, Sarah Dalgas
    EQUINE VETERINARY EDUCATION, 2023, 35 (07) : 340 - 346
  • [10] Implantable loop recorder in atrial fibrillation and after catheter ablation
    Fikenzer K.
    Dagres N.
    Hindricks G.
    Herzschrittmachertherapie + Elektrophysiologie, 2016, 27 (4) : 355 - 359