Honey-Water Content Analysis by Mixing Models Using a Self-Calibrating Microwave Method

被引:3
|
作者
Hasar, Hafize [1 ,2 ]
Hasar, Ugur C. [3 ]
Kaya, Yunus [4 ]
Ozturk, Hamdullah [3 ]
Izginli, Mucahit [3 ]
Oztas, Taskin [1 ,2 ]
Aslan, Nevzat [5 ]
Ertugrul, Mehmet [6 ]
Barroso, Joaquim J. [7 ]
Ramahi, Omar M. [8 ]
机构
[1] Ataturk Univ, Dept Soil Sci & Plant Nutr, TR-25240 Erzurum, Turkey
[2] Minist Agr & Forestry Republ Turkey, Gaziantep Directorate Prov Agr & Forestry, TR-27090 Gaziantep, Turkey
[3] Gaziantep Univ, Dept Elect & Elect Engn, TR-27310 Gaziantep, Turkey
[4] Bayburt Univ, Dept Elect & Energy, TR-69000 Bayburt, Turkey
[5] Minist Agr & Forestry, Pistachio Res Inst Republ Turkey, TR-27060 Gaziantep, Turkey
[6] Ataturk Univ, Dept Elect & Elect Engn, TR-25240 Erzurum, Turkey
[7] Inst Tecnol Aeronaut, BR-12228900 Sao Jose Dos Campos, SP, Brazil
[8] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
关键词
Permittivity measurement; Microwave measurement; Electromagnetic waveguides; Microwave theory and techniques; Liquids; Calibration; Time measurement; Adulteration; binary mixing models; honey; microwave techniques; self-calibration; water content analysis; COMPLEX PERMITTIVITY DETERMINATION; INDEPENDENT METHOD; OPTICAL-PROPERTIES; REFLECTION; RETRIEVAL; CONSTANT; LIQUID;
D O I
10.1109/TMTT.2022.3208024
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Microwave techniques, as an indirect approach, can be applied for analyzing water content in honey by way of permittivity measurements. However, these techniques require proper calibration to accurately perform such indirect evaluation. Improper calibration standards used in this calibration process could naturally result in a reduction in the accuracy and thus the performance of dielectric characterization using microwaves. Self-calibrating microwave techniques can reduce the effects of imprecise standards and thus improve the performance of microwave measurements by bypassing the requirement of calibration standards. In this study, we develop a self-calibrating microwave measurement technique to determine the relative permittivity of honey samples and implement binary mixing models to predict adulteration levels of water-adulterated honey. From this implementation, it is observed that the parallel-capacitance mixing model could efficiently be applied to determine the concentration of water adulteration by examining the differences between absolute values of the real parts of the measured and predicted complex permittivities of adulterated honey.
引用
收藏
页码:691 / 697
页数:7
相关论文
共 27 条
  • [1] Self-calibrating evaluation method for microwave interferometry measurements
    Prihoda, M.
    Hoffmann, K.
    [J]. ELECTRONICS LETTERS, 2013, 49 (05) : 356 - 357
  • [2] Self-Calibrating Gain Stabilization Method for Applications Using Silicon Photomultipliers
    Baszczyk, Mateusz
    Dorosz, Piotr
    Glab, Sebastian
    Kucewicz, Wojciech
    Mik, Lukasz
    Sapor, Maria
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [3] Validation and uncertainty analysis of a reduced self-calibrating method for pitch measurements of cylindrical gears
    Keller, F.
    Stein, M.
    Kniel, K.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (06)
  • [4] SELF-CALIBRATING INTERFERENCE REFRACTOMETER USING A LINEAR PHOTODIODE ARRAY FOR ANESTHETIC GAS-ANALYSIS
    JACKSON, RK
    PALAYIWA, E
    SUGG, BR
    HAHN, CEW
    WELLER, S
    DAVIES, WL
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (05) : 516 - 522
  • [5] Evaluation of water content in honey using microwave transmission line technique
    Li, Zhen
    Haigh, Arthur
    Soutis, Constantinos
    Gibson, Andrew
    Sloan, Robin
    [J]. JOURNAL OF FOOD ENGINEERING, 2017, 215 : 113 - 125
  • [6] LOW-COST 3D LASER SCANNING IN AIR OR WATER USING SELF-CALIBRATING STRUCTURED LIGHT
    Bleier, Michael
    Nuechter, Andreas
    [J]. 3D VIRTUAL RECONSTRUCTION AND VISUALIZATION OF COMPLEX ARCHITECTURES, 2017, 42-2 (W3): : 105 - 112
  • [7] Spatiotemporal analysis of droughts using self-calibrating Palmer's Drought Severity Index in the central region of South Africa
    Edossa, Desalegn C.
    Woyessa, Yali E.
    Welderufael, Worku A.
    [J]. THEORETICAL AND APPLIED CLIMATOLOGY, 2016, 126 (3-4) : 643 - 657
  • [8] Spatiotemporal analysis of droughts using self-calibrating Palmer’s Drought Severity Index in the central region of South Africa
    Desalegn C. Edossa
    Yali E. Woyessa
    Worku A. Welderufael
    [J]. Theoretical and Applied Climatology, 2016, 126 : 643 - 657
  • [9] Noncontact method for sensing thickness and refractive index of intraocular lens implants using a self-calibrating dual-confocal laser caliper
    Kim, Do-Hyun
    James, Robert
    Calogero, Don
    Ilev, Ilko K.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (06)
  • [10] Using Seafloor Geodesy to Detect Vertical Deformation at the Hikurangi Subduction Zone: Insights From Self-Calibrating Pressure Sensors and Ocean General Circulation Models
    Woods, K.
    Webb, S. C.
    Wallace, L. M.
    Ito, Y.
    Collins, C.
    Palmer, N.
    Hino, R.
    Savage, M. K.
    Saffer, D. M.
    Davis, E. E.
    Barker, D. H. N.
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2022, 127 (12)