Exploring Simple Particle-Based Signal Amplification Strategies in a Heterogeneous Sandwich Immunoassay with Optical Detection

被引:1
|
作者
Geissler, Daniel [1 ]
Wegner, K. David [1 ]
Fischer, Christin [1 ]
Resch-Genger, Ute [1 ]
机构
[1] BAM Fed Inst Mat Res & Testing, Div Biophoton, D-12489 Berlin, Germany
关键词
LATERAL FLOW IMMUNOASSAY; UP-CONVERSION; NANOPARTICLES; HYDROPHILICITY; FLUOROPHORES; RELEASE; LABELS; STATE; DYES;
D O I
10.1021/acs.analchem.3c03691
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Heterogeneous sandwich immunoassays are widely used for biomarker detection in bioanalysis and medical diagnostics. The high analyte sensitivity of the current "gold standard" enzyme-linked immunosorbent assay (ELISA) originates from the signal-generating enzymatic amplification step, yielding a high number of optically detectable reporter molecules. For future point-of-care testing (POCT) and point-of-need applications, there is an increasing interest in more simple detection strategies that circumvent time-consuming and temperature-dependent enzymatic reactions. A common concept to aim for detection limits comparable to those of enzymatic amplification reactions is the usage of polymer nanoparticles (NP) stained with a large number of chromophores. We explored different simple NP-based signal amplification strategies for heterogeneous sandwich immunoassays that rely on an extraction-triggered release step of different types of optically detectable reporters. Therefore, streptavidin-functionalized polystyrene particles (PSP) are utilized as carriers for (i) the fluorescent dye coumarin 153 (C153) and (ii) hemin (hem) molecules catalyzing the luminol reaction enabling chemiluminescence (CL) detection. Additionally, (iii) NP labeling with hemin-based microperoxidase MP11 was assessed. For each amplification approach, the PSP was first systematically optimized regarding size, loading concentration, and surface chemistry. Then, for an immunoassay for the inflammation marker C-reactive protein (CRP), the analyte sensitivity achievable with optimized PSP systems was compared with the established ELISA concept for photometric and CL detection. Careful optimization led to a limit of detection (LOD) of 0.1 ng/mL for MP11-labeled PSP and CL detection, performing similarly well to a photometric ELISA (0.13 ng/mL), which demonstrates the huge potential of our novel assay concept. [GRAPHICS] .
引用
收藏
页码:5078 / 5085
页数:8
相关论文
共 50 条
  • [1] Three different signal amplification strategies for the impedimetric sandwich detection of thrombin
    Ocana, Cristina
    del Valle, Manel
    ANALYTICA CHIMICA ACTA, 2016, 912 : 117 - 124
  • [2] Multiplexed, particle-based detection of DNA using flow cytometry with 3DNA dendrimers for signal amplification
    Lowe, M
    Spiro, A
    Zhang, YZ
    Getts, R
    CYTOMETRY PART A, 2004, 60A (02): : 135 - 144
  • [3] Magnetic particle-based immunoassay of phosphorylated p53 using protein cage templated lead phosphate and carbon nanospheres for signal amplification
    Chen, Aiqiong
    Bao, Yuanwu
    Ge, Xiaoxiao
    Shin, Yongsoon
    Du, Dan
    Lin, Yuehe
    RSC ADVANCES, 2012, 2 (29): : 11029 - 11034
  • [4] Development of a novel magnetic particle-based agglutination immunoassay for anticardiolipin antibody detection in syphilis
    Shukla, Mayur R.
    Deutsch, John W.
    Pereira, Lara E.
    Kersh, Ellen N.
    Fakile, Yetunde F.
    SEXUALLY TRANSMITTED INFECTIONS, 2020, 96 (06) : 411 - 416
  • [5] Quantitation of SPLUNC1 in saliva with an xMAP particle-based antibody capture and detection immunoassay
    Kohlgraf, Karl G.
    Ackermann, Abbey R.
    Burnell, Kindra K.
    Srikantha, Rupasree N.
    Joly, Sophie A.
    Bartlett, Jennifer A.
    Gakhar, Lokesh
    Johnson, Georgia K.
    McCray, Paul B., Jr.
    Guthmiller, Janet M.
    Brogiden, Kim A.
    ARCHIVES OF ORAL BIOLOGY, 2012, 57 (02) : 197 - 204
  • [6] Development of Magnetic Particle-based Chemiluminescence Enzyme Immunoassay for the Detection of 17β-estradiol in Environmental Water
    Tian-Bing Xin
    Xu Wang
    Hui Jin
    Shu-Xuan Liang
    Jin-Ming Lin
    Zhen-Jia Li
    Applied Biochemistry and Biotechnology, 2009, 158 : 582 - 594
  • [7] Development of Magnetic Particle-based Chemiluminescence Enzyme Immunoassay for the Detection of 17β-estradiol in Environmental Water
    Xin, Tian-Bing
    Wang, Xu
    Jin, Hui
    Liang, Shu-Xuan
    Lin, Jin-Ming
    Li, Zhen-Jia
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2009, 158 (03) : 582 - 594
  • [8] A full-automated magnetic particle-based chemiluminescence immunoassay for rapid detection of cortisol in milk
    Fu, Hui-Jun
    Yuan, Li-Peng
    Shen, Yu-Dong
    Liu, Yi-Xin
    Liu, Bo
    Zhang, Shi-Wei
    Xie, Zhuo-Xun
    Lei, Hong-Tao
    Sun, Yuan-Ming
    Xu, Zhen-Lin
    ANALYTICA CHIMICA ACTA, 2018, 1035 : 129 - 135
  • [9] Development of a Fluorescence Immunoassay for Bisphenol a Detection Based on Functionalized Nanogold Signal Amplification Strategy
    Zhao, Wei
    Zhang, Chun-yan
    Li, Chun-gang
    Du, Ling-yun
    2016 INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND ENGINEERING (ESE 2016), 2016, : 358 - 362
  • [10] Electrochemical immunoassay for procalcitonin antigen detection based on signal amplification strategy of multiple nanocomposites
    Fang, Yi-Shan
    Wang, Hai-Ying
    Wang, Li-Shi
    Wang, Ju-Fang
    BIOSENSORS & BIOELECTRONICS, 2014, 51 : 310 - 316