RapidBrachyTG43: A Geant4-based TG-43 parameter and dose calculation module for brachytherapy dosimetry

被引:1
|
作者
Kalinowski, Jonathan [1 ,2 ,3 ]
Enger, Shirin A. [1 ,2 ]
机构
[1] McGill Univ, Fac Med, Dept Oncol, Med Phys Unit, Montreal, PQ, Canada
[2] Jewish Gen Hosp, Lady Davis Inst Med Res, Montreal, PQ, Canada
[3] Jewish Gen Hosp, Radiat Oncol Dept, Room G18-223,3755 Chemin Cote St Catherine, Montreal, PQ H3T 1E2, Canada
基金
加拿大健康研究院;
关键词
brachytherapy; Monte Carlo; TG-43; AVERAGE ENERGY HIGHER; 2004; UPDATE; AAPM; RECOMMENDATIONS; SUPPLEMENT; TRANSPORT;
D O I
10.1002/mp.16948
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe AAPM TG-43U1 formalism remains the clinical standard for dosimetry of low- and high-energy gamma-emitting brachytherapy sources. TG-43U1 and related reports provide consensus datasets of TG-43 parameters derived from various published measured data and Monte Carlo simulations. These data are used to perform standardized and fast dose calculations for brachytherapy treatment planning.PurposeMonte Carlo TG-43 dosimetry parameters are commonly derived to characterize novel brachytherapy sources. RapidBrachyTG43 is a module of RapidBrachyMCTPS, a Monte Carlo-based treatment planning system, designed to automate this process, requiring minimal user input to prepare Geant4-based Monte Carlo simulations for a source. RapidBrachyTG43 may also perform a TG-43 dose to water-in-water calculation for a plan, substantially accelerating the same calculation performed using RapidBrachyMCTPS's Monte Carlo dose calculation engine.MethodsTG-43 parameters SK/A$S_K/A$, Lambda, gL(r)$g_L(r)$, and F(r,theta)$F(r,\theta)$ were calculated using three commercial source models, one each of 125I, 192Ir, and 60Co, and were benchmarked to published data. TG-43 dose to water was calculated for a clinical breast brachytherapy plan and was compared to a Monte Carlo dose calculation with all patient tissues, air, and catheters set to water.ResultsTG-43 parameters for the three simulated sources agreed with benchmark datasets within tolerances specified by the High Energy Brachytherapy Dosimetry working group. A gamma index comparison between the TG-43 and Monte Carlo dose-to-water calculations with a dose difference and difference to agreement criterion of 1%/1 mm yielded a 98.9% pass rate, with all relevant dose volume histogram metrics for the plan agreeing within 1%. Performing a TG-43-based dose calculation provided an acceleration of dose-to-water calculation by a factor of 165.ConclusionsDetermination of TG-43 parameter data for novel brachytherapy sources may now be facilitated by RapidBrachyMCTPS. These parameter datasets and existing consensus or published datasets may also be used to determine the TG-43 dose for a plan in RapidBrachyMCTPS.
引用
收藏
页码:3746 / 3757
页数:12
相关论文
共 50 条
  • [1] RapidBrachyTG43: A TG-43 PARAMETER AND DOSE CALCULATION MODULE FOR RapidBrachyMCTPs
    Kalinowski, Jonathan
    Enger, Shirin
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S81 - S81
  • [2] The TG-43 brachytherapy dose calculation formalism
    Rivard, Mark J.
    [J]. Brachytherapy Physics, Second Edition, 2005, (31): : 295 - 324
  • [3] Brachytherapy TG-43 dosimetry characterization of the INTRABEAM source
    Alvarez, D. S. Ayala
    Watson, P. G. F.
    Popovic, M.
    Heng, V. J.
    Evans, M. D. C.
    Seuntjens, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S97 - S99
  • [4] Consideration of the updated TG-43 brachytherapy dosimetry formalism
    Rivard, MJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S13 - S13
  • [5] Dose prescriptions and the TG-43 dosimetry protocol
    Wallace, R
    [J]. GENERAL PRACTICE OF RADIATION ONCOLOGY PHYSICS IN THE 21ST CENTURY, 2000, (26): : 233 - 248
  • [6] Application of the TG-43 dosimetry protocol to electronic brachytherapy sources
    Rusch, T
    Rivard, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S84 - S84
  • [7] Update to the TG-43 report: A revised protocol for brachytherapy dosimetry
    Rivard, MJ
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1835 - 1835
  • [8] The dosimetric impact of replacing the TG-43 algorithm by model based dose calculation for liver brachytherapy
    Duque, Anna Sophie
    Corradini, Stefanie
    Kamp, Florian
    Seidensticker, Max
    Streitparth, Florian
    Kurz, Christopher
    Walter, Franziska
    Parodi, Katia
    Verhaegen, Frank
    Ricke, Jens
    Belka, Claus
    Fonseca, Gabriel Paiva
    Landry, Guillaume
    [J]. RADIATION ONCOLOGY, 2020, 15 (01)
  • [9] The dosimetric impact of replacing the TG-43 algorithm by model based dose calculation for liver brachytherapy
    Anna Sophie Duque
    Stefanie Corradini
    Florian Kamp
    Max Seidensticker
    Florian Streitparth
    Christopher Kurz
    Franziska Walter
    Katia Parodi
    Frank Verhaegen
    Jens Ricke
    Claus Belka
    Gabriel Paiva Fonseca
    Guillaume Landry
    [J]. Radiation Oncology, 15
  • [10] Accuracy Verification of Dose Calculation Algorithm Based-on TG-43 and AcurosBV on HDR Brachytherapy
    Nakkrasae, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127