Diagnostic accuracy of thoracic CT to differentiate transudative from exudative pleural effusion prior to thoracentesis

被引:1
|
作者
Zhang, Yan [1 ]
Zhang, Yang [2 ]
Wang, Wei [3 ]
Feng, Xiaoyu [2 ]
Guo, Jiahuan [2 ]
Chen, Bo [3 ]
Zhang, Fuyun [3 ]
Wang, Huanhuan [3 ]
Fan, Mengnan [4 ]
Zhu, Yingwei [3 ]
Sun, Yuxia [3 ]
Wang, Tongsheng [3 ]
Mao, Yimin [3 ]
Gao, Pengfei [3 ]
机构
[1] Henan Univ Sci & Technol, Affiliated Hosp 1, Coll Clin Med, Dept Gen Med, Luoyang, Henan, Peoples R China
[2] Zhengzhou Univ, Affiliated Hosp 1, Dept Resp & Crit Care Med, Zhengzhou, Henan, Peoples R China
[3] Henan Univ Sci & Technol, Affiliated Hosp 1, Coll Clin Med, Dept Resp & Crit Care Med, 24 Jing Hua Rd, Luoyang 471003, Henan, Peoples R China
[4] Henan Univ Sci & Technol, Affiliated Hosp 1, Coll Clin Med, Dept Med Record, Luoyang, Henan, Peoples R China
关键词
Pleural effusion; Thoracic CT; Diagnosis; Exudate; Transudate; COMPUTED-TOMOGRAPHY; ATTENUATION VALUES; ANEMIA; EFFICACY;
D O I
10.1186/s12931-024-02681-w
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
BackgroundComputed tomography (CT) scan is commonly performed for pleural effusion diagnostis in the clinic. However, there are limited data assessing the accuracy of thoracic CT for the separation of transudative from exudative effusions. The study aimed to determine the diagnostic value of thoracic CT in distinguishing transudates from exudates in patients with pleural effusion.MethodsThis is a two-center retrospective analysis of patients with pleural effusion, a total of 209 patients were included from The First Affiliated Hospital of Henan University of Science and Technology as the derivation cohort (Luoyang cohort), and 195 patients from the First Affiliated Hospital of Zhengzhou University as the validation cohort (Zhengzhou cohort). Patients who underwent thoracic CT scan followed by diagnostic thoracentesis were enrolled. The optimal cut-points of CT value in pleural fluid (PF) and PF to blood CT value ratio for predicting a transudative vs. exudative pleural effusions were determined in the derivation cohort and further verified in the validation cohort.ResultsIn the Derivation (Luoyang) cohort, patients with exudates had significantly higher CT value [13.01 (10.01-16.11) vs. 4.89 (2.31-9.83) HU] and PF to blood CT value ratio [0.37 (0.27-0.53) vs. 0.16 (0.07-0.26)] than those with transudates. With a cut-off value of 10.81 HU, the area under the curve (AUC), sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of CT value were 0.85, 88.89%, 68.90%, 43.96%, and 95.76%, respectively. The optimum cut-value for PF to blood CT value ratio was 0.27 with AUC of 0.86, yielding a sensitivity of 61.11%, specificity of 86.36%, PPV of 78.57%, and NPV of 73.08%. These were further verified in the Validation (Zhengzhou) cohort.ConclusionsCT value and PF to blood CT value ratio showed good differential abilities in predicting transudates from exudates, which may help to avoid unnecessary thoracentesis.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Diagnostic accuracy of thoracic CT to differentiate transudative from exudative pleural effusion prior to thoracentesis
    Yan Zhang
    Yang Zhang
    Wei Wang
    Xiaoyu Feng
    Jiahuan Guo
    Bo Chen
    Fuyun Zhang
    Huanhuan Wang
    Mengnan Fan
    Yingwei Zhu
    Yuxia Sun
    Tongsheng Wang
    Yimin Mao
    Pengfei Gao
    Respiratory Research, 25
  • [2] Diagnostic Accuracy of Thoracic Ultrasonography to Differentiate Transudative From Exudative Pleural Effusion
    Shkolnik, Boris
    Judson, Marc A.
    Austin, Adam
    Hu, Kurt
    D'Souza, Melissa
    Zumbrunn, Alexis
    Huggins, John T.
    Yucel, Recai
    Chopra, Amit
    CHEST, 2020, 158 (02) : 692 - 697
  • [4] Diagnostic Accuracy of Thoracic Ultrasonography to Differentiate Transudative From Exudative Pleural Effusion Methodological Issues Response
    Shkolnik, Boris
    Judson, Marc A.
    Austin, Adam
    Hu, Kurt
    D'souza, Melissa
    Zumbrunn, Alexis
    Huggins, John T.
    Yucel, Recai
    Chopra, Amit
    CHEST, 2020, 158 (04) : 1783 - 1784
  • [5] Diagnostic accuracy of drop-peroxide test to differentiate transudative and exudative pleural effusion
    Vasu, Kotti Phanindra
    Kumar, K. V. V. Vijaya
    Rajyalakshmi, Gurram
    Priyanka, Chintha L. N. Yamini
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [6] Diagnostic value of pleural cholesterol in differentiating exudative and transudative pleural effusion
    Gautam, Santosh
    Raj, K. C. Shiva
    Bhattarai, Binita
    Geetika, K. C.
    Adhikari, Gauri
    Gyawali, Purnima
    Rijal, Keshab
    Sijapati, Milesh Jung
    ANNALS OF MEDICINE AND SURGERY, 2022, 82
  • [7] Pleural Fluid Cholesterol and Bilirubin Value in Diagnostic of Exudative from Transudative Pleural Effusion
    Ataei, B.
    Araghi, A.
    Kassaian, N.
    Nokhodian, Z.
    Karimi, I.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2008, 12 : E460 - E461
  • [8] The Accuracy of Chest Computed Tomography Findings in Differentiation of Exudative from Transudative Pleural Effusion
    Rashid, Reza Javad
    Jalili, Javad
    Arhami, Shohreh Sadr
    Heris, Hengameh Khadivi
    Habibzadeh, Afshin
    Mohtasham, Masumeh Ahmadi
    JOURNAL OF CLINICAL AND ANALYTICAL MEDICINE, 2015, 6 (03) : 341 - 344
  • [9] Role of pleural fluid cholesterol in differentiating transudative from exudative pleural effusion
    Guleria, R
    Agarwal, SR
    Sinha, S
    Pande, JN
    Misra, A
    NATIONAL MEDICAL JOURNAL OF INDIA, 2003, 16 (02): : 64 - 69
  • [10] Pleural Fluid Cholesterol in Differentiating Exudative and Transudative Pleural Effusion
    Hamal, A. B.
    Yogi, K. N.
    Bam, N.
    Das, S. K.
    Karn, R.
    PULMONARY MEDICINE, 2013, 2013