Comparison of three HPLC analytical methods: ELSD, RID, and UVD for the analysis of xylitol in foods

被引:2
|
作者
Seo, Eunbin [1 ]
Yun, Choong-In [2 ,3 ]
Park, Jin-Wook [1 ]
Lee, Gayeong [1 ]
Kim, Young-Jun [1 ,3 ]
机构
[1] Seoul Natl Univ Sci & Technol, Dept Food Sci & Technol, Seoul 01811, South Korea
[2] Sungkyunkwan Univ, Dept Food Sci & Biotechnol, Suwon 16419, South Korea
[3] Seoul Natl Univ Sci & Technol, Res Inst Food & Biotechnol, Seoul 01811, South Korea
关键词
Evaporative light scattering detector; HPLC; Refractive index detector; Ultraviolet detector; Xylitol; ERYTHRITOL; PRODUCTS;
D O I
10.1007/s10068-024-01550-y
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
In this study, xylitol, a common sweetener and sucrose substitute in low-calorie foods, was quantified by high-performance liquid chromatography (HPLC). During the establishment of the analytical method, three representative detection approaches, ultraviolet detector (UVD), evaporative light scattering detector, and refractive index detector, were compared and applied to determine the xylitol content in various foods distributed in Korea. The results were compared for method validation, measurement uncertainty, and applicability. As a result, HPLC-UVD showed the lowest limit of detection (0.01 mg/L) and limit of quantification (0.04 mg/L) among the three methods. It showed a low range of relative expanded uncertainty (1.12-3.98%) and could quantify xylitol in the wide range of the samples, even trace amounts of xylitol. Therefore, a total of 160 food items, including chewing gum, candy, beverage, tea, other processed products, and beverage base, were applied with three replicates by the proposed HPLC-UVD method.
引用
收藏
页码:2971 / 2978
页数:8
相关论文
共 50 条
  • [1] Comparison of ELSD and RID combined with HPLC for simultaneous determination of six rare sugars in food components
    Luo, Xiaohu
    Liu, Yu
    Xing, Jiali
    Bi, Xiaoli
    Shen, Jian
    Zhang, Shufen
    Xu, Xiaorong
    Mao, Lingyan
    Lou, Yongjiang
    MICROCHEMICAL JOURNAL, 2024, 201
  • [2] Development and validation of analytical methods for pyrifluquinazon residues determination on agricultural commodities by HPLC-UVD
    Do, Jung-Ah
    Kwon, Ji-Eun
    Kim, Mi-Ra
    Lee, Eun-Mi
    Kuk, Ju-Hee
    Cho, Yoon-Jae
    Chang, Moon-Ik
    Kwon, Kisung
    Oh, Jae-Ho
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2013, 26 (03): : 174 - 181
  • [3] Establishment of analytical methods for forchlorfenuron and inabenfide, plant growth regulators, in agricultural commodities using HPLC/UVD
    Lee, Sang-Mok
    Chang, Moon-ik
    Yoon, Ji-Young
    Lee, Han-Jin
    Lee, Dogsuk
    Kyung, Yena
    Rhee, Gyuseek
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [4] Comparison of spectrophotometric and HPLC methods for determination of carotenoids in foods
    Luterotti, Svjetlana
    Markovic, Ksenija
    Frank, Mladen
    Bicanic, Dane
    Madzgalj, Azamela
    Kljak, Kristina
    FOOD CHEMISTRY, 2013, 140 (1-2) : 390 - 397
  • [5] Comparison of three analytical methods for cocaine analysis of illicit powders
    Campanella, L
    Colapicchioni, C
    Tomassetti, M
    Dezzi, S
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (8-10) : 1047 - 1054
  • [6] Comparison of analytical methods for protein level determination in foods
    Azih, Mark
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254
  • [7] Protein level determination in foods: A comparison of analytical methods
    Azih, Mark
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [8] Analytical determination of phosphatidylcholine: comparison of HPLC and enzymatic methods
    Montanes, AB
    Fabregas, JJP
    FOOD CHEMISTRY, 1997, 60 (04) : 675 - 679
  • [9] Comparison of methods for iodine analysis in foods
    Judprasong, K.
    Jongjaithet, N.
    Chavasit, V.
    FOOD CHEMISTRY, 2016, 193 : 12 - 17
  • [10] COMPARISON OF THE EVAPORATIVE LIGHT-SCATTERING DETECTOR (ELSD) AND REFRACTIVE-INDEX DETECTOR (RID) IN LIPID ANALYSIS
    HOPIA, AI
    OLLILAINEN, VM
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (12): : 2469 - 2482