Extended MRI-based PET motion correction for cardiac PET/MRI

被引:1
|
作者
Aizaz, Mueez [1 ,2 ]
van der Pol, Jochem A. J. [1 ,2 ]
Schneider, Alina [3 ]
Munoz, Camila [3 ]
Holtackers, Robert J. [1 ,2 ,3 ]
van Cauteren, Yvonne [1 ,5 ]
van Langen, Herman [4 ]
Meeder, Joan G. [5 ]
Rahel, Braim M. [5 ]
Wierts, Roel [2 ]
Botnar, Rene M. [3 ,6 ,7 ,8 ]
Prieto, Claudia [3 ,6 ,7 ]
Moonen, Rik P. M. [1 ,2 ]
Kooi, M. Eline [1 ,2 ]
机构
[1] Maastricht Univ, Cardiovasc Res Inst Maastricht, CARIM, Maastricht, Netherlands
[2] Maastricht Univ, Med Ctr, Dept Radiol & Nucl Med, Maastricht, Netherlands
[3] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[4] VieCuri Med Ctr, Dept Med Phys & Devices, Venlo, Netherlands
[5] VieCuri Med Ctr, Dept Cardiol, Venlo, Netherlands
[6] Pontificia Univ Catolica Chile, Escuela Ingn, Santiago, Chile
[7] Millenium Inst Intelligent Healthcare Engn iHEALTH, Santiago, Chile
[8] Pontificia Univ Catolica Chile, Inst Ingn Biol & Med, Santiago, Chile
关键词
PET/MRI; Motion correction; 2-Dimensional image navigator; Respiratory belt; Binning; Signal-to-noise ratio; RECONSTRUCTION; COMPENSATION; ANGIOGRAPHY; NOISE;
D O I
10.1186/s40658-024-00637-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A 2D image navigator (iNAV) based 3D whole-heart sequence has been used to perform MRI and PET non-rigid respiratory motion correction for hybrid PET/MRI. However, only the PET data acquired during the acquisition of the 3D whole-heart MRI is corrected for respiratory motion. This study introduces and evaluates an MRI-based respiratory motion correction method of the complete PET data. Methods: Twelve oncology patients scheduled for an additional cardiac F-18-Fluorodeoxyglucose (F-18-FDG) PET/MRI and 15 patients with coronary artery disease (CAD) scheduled for cardiac F-18-Choline (F-18-FCH) PET/MRI were included. A 2D iNAV recorded the respiratory motion of the myocardium during the 3D whole-heart coronary MR angiography (CMRA) acquisition (similar to 10 min). A respiratory belt was used to record the respiratory motion throughout the entire PET/MRI examination (similar to 30-90 min). The simultaneously acquired iNAV and respiratory belt signal were used to divide the acquired PET data into 4 bins. The binning was then extended for the complete respiratory belt signal. Data acquired at each bin was reconstructed and combined using iNAV-based motion fields to create a respiratory motion-corrected PET image. Motion-corrected (MC) and non-motion-corrected (NMC) datasets were compared. Gating was also performed to correct cardiac motion. The SUVmax and TBRmax values were calculated for the myocardial wall or a vulnerable coronary plaque for the F-18-FDG and F-18-FCH datasets, respectively. Results: A pair-wise comparison showed that the SUVmax and TBRmax values of the motion corrected (MC) datasets were significantly higher than those for the non-motion-corrected (NMC) datasets (8.2 +/- 1.0 vs 7.5 +/- 1.0, p < 0.01 and 1.9 +/- 0.2 vs 1.2 +/- 0.2, p < 0.01, respectively). In addition, the SUVmax and TBRmax of the motion corrected and gated (MC_G) reconstructions were also higher than that of the non-motion-corrected but gated (NMC_G) datasets, although for the TBRmax this difference was not statistically significant (9.6 +/- 1.3 vs 9.1 +/- 1.2, p = 0.02 and 2.6 +/- 0.3 vs 2.4 +/- 0.3, p = 0.16, respectively). The respiratory motion-correction did not lead to a change in the signal to noise ratio. Conclusion: The proposed respiratory motion correction method for hybrid PET/MRI improved the image quality of cardiovascular PET scans by increased SUVmax and TBRmax values while maintaining the signal-to-noise ratio.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Extended MRI-based PET motion correction for cardiac PET/MRI
    Mueez Aizaz
    Jochem A. J. van der Pol
    Alina Schneider
    Camila Munoz
    Robert J. Holtackers
    Yvonne van Cauteren
    Herman van Langen
    Joan G. Meeder
    Braim M. Rahel
    Roel Wierts
    René M. Botnar
    Claudia Prieto
    Rik P. M. Moonen
    M. Eline Kooi
    EJNMMI Physics, 11
  • [2] MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI
    Chun, Se Young
    Reese, Timothy G.
    Ouyang, Jinsong
    Guerin, Bastien
    Catana, Ciprian
    Zhu, Xuping
    Alpert, Nathaniel M.
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (08) : 1284 - 1291
  • [3] MRI-based motion correction of thoracic PET: initial comparison of acquisition protocols and correction strategies suitable for simultaneous PET/MRI systems
    Nikolaos Dikaios
    David Izquierdo-Garcia
    Martin J. Graves
    Venkatesh Mani
    Zahi A. Fayad
    Tim D. Fryer
    European Radiology, 2012, 22 : 439 - 446
  • [4] MRI-based motion correction of thoracic PET: initial comparison of acquisition protocols and correction strategies suitable for simultaneous PET/MRI systems
    Dikaios, Nikolaos
    Izquierdo-Garcia, David
    Graves, Martin J.
    Mani, Venkatesh
    Fayad, Zahi A.
    Fryer, Tim D.
    EUROPEAN RADIOLOGY, 2012, 22 (02) : 439 - 446
  • [5] Attenuation Correction for PET/MRI Using MRI-based Pseudo CT
    Wang, Tonghe
    Lei, Yang
    Dong, Xue
    Higgins, Kristin
    Liu, Tian
    Curran, Walter J.
    Mao, Hui
    Nye, Jonathon A.
    Yang, Xiaofeng
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [6] MRI-based attenuation correction and quantification tools for combined MRI/PET
    Fei, Baowei
    Yang, Xiaofeng
    Nye, Jonathon
    Jones, Margie
    Aarsvold, John
    Raghunath, Nivedita
    Meltzer, Carolyn
    Votaw, John
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [7] Three MRI-based attenuation correction methods for PET
    Marshall, Harry
    Laidley, David
    Patrick, John
    Butler, John
    Thompson, Robert
    Prato, Frank
    Rachinsky, Irina
    Stodilka, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [8] Markerless motion tracking and correction for PET, MRI, and simultaneous PET/MRI
    Slipsager, Jakob M.
    Ellegaard, Andreas H.
    Glimberg, Stefan L.
    Paulsen, Rasmus R.
    Tisdall, M. Dylan
    Wighton, Paul
    van der Kouwe, Andre
    Marner, Lisbeth
    Henriksen, Otto M.
    Law, Ian
    Olesen, Oline V.
    PLOS ONE, 2019, 14 (04):
  • [9] Evaluation of an MRI-based partial volume correction for PET.
    Liow, J
    Zaini, M
    Rehm, K
    Strother, S
    Anderson, J
    Schaper, K
    Rottenberg, D
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 100P - 100P
  • [10] Motion Correction Options in PET/MRI
    Catana, Ciprian
    SEMINARS IN NUCLEAR MEDICINE, 2015, 45 (03) : 212 - 223