Test-retest reliability and minimal detectable change of four functional tests in community-dwelling older adults with high risk of falls

被引:1
|
作者
Intaruk, Roongnapa [1 ,2 ]
Phadungkit, Supaporn [1 ]
Kanpai, Anongnat [1 ]
Pawanta, Ketmanee [1 ]
Srihapol, Nuttanicha [1 ]
Saengsuwan, Jittima [3 ]
Amatachaya, Sugalya [1 ,2 ]
Thaweewannakij, Thiwabhorn [1 ,2 ]
机构
[1] Khon Kaen Univ, Fac Associated Med Sci, Sch Phys Therapy, 123 Moo 16 Mittraphap Rd, Khon Kaen 40002, Thailand
[2] Khon Kaen Univ, Improvement Phys Performance & Qual Life IPQ Res G, Khon Kaen, Thailand
[3] Khon Kaen Univ, Fac Med, Dept Rehabil Med, Khon Kaen, Thailand
关键词
Falls; functional performance; measurement error; older adults; reproducibility of results; PHYSICAL PERFORMANCE; ELDERLY-PEOPLE; GAIT SPEED; WALK TEST; GO; CONSEQUENCES; VALIDITY; MOBILITY; STRENGTH; BALANCE;
D O I
10.5606/tftrd.2024.12725
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: This study aimed to quantify test-retest reliability and minimal detectable change (MDC) of the four commonly used functional tests in older adults with a high risk of falling.Patients and methods: The cross-sectional study was conducted with 30 community-dwelling older adults (26 females, 4 males; mean age: 73.7 +/- 6.0 years; range, 65 to 88 years) with a high fall risk identified by the Thai falls risk assessment test between November 2018 and May 2019. Data from the 10-m walk test at a comfortable gait speed (CGS) and fast gait speed (FGS), timed up and go (TUG) test, five times sit to stand test (FTSST), and 6-min walk test (6MWT) were collected twice for each participant. The interval between test sessions was one week. Test-retest reliability was analyzed by the intraclass correlation coefficient (ICC). Standard error of measurement (SEM) and MDC at the 95% confidence interval (MDC95) were also calculated.Results: The four functional tests had ICC in the range of 0.92 to 0.97. The SEM values of the CGS, FGS, TUG, FTSST, and 6MWT were 0.06 m/sec, 0.04 m/sec, 1.10 sec, 1.30 sec, and 20.60 m, respectively. The MDC95 values of the CGS, FGS, TUG, FTSST, and 6MWT were 0.16 m/sec, 0.12 m/sec, 3.00 sec, 3.50 sec, and 57.20 m, respectively.Conclusion: All functional tests demonstrated excellent test-retest reliability. The SEM and MDC95 of all functional tests were established. These findings can help clinicians interpret the effectiveness of interventions and determine changes in functional ability over time in older adults at high risk of falls.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [1] Test-Retest Reliability and Minimal Detectable Change of Four Cognitive Tests in Community-Dwelling Older Adults
    Webb, Katherine L.
    Ryan, Joanne
    Wolfe, Rory
    Woods, Robyn L.
    Shah, Raj C.
    Murray, Anne M.
    Orchard, Suzanne G.
    Storey, Elsdon
    [J]. JOURNAL OF ALZHEIMERS DISEASE, 2022, 87 (04) : 1683 - 1693
  • [2] Interrater and Test-Retest Reliability and Minimal Detectable Change of the Balance Evaluation Systems Test (BESTest) and Subsystems With Community-Dwelling Older Adults
    Wang-Hsu, Elizabeth
    Smith, Susan S.
    [J]. JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2018, 41 (03) : 173 - 179
  • [3] Test-Retest Reliability and Reliable Change Estimates for Four Mobile Cognitive Tests Administered Virtually in Community-Dwelling Adults
    Van Patten, Ryan
    Iverson, Grant L.
    Muzeau, Melissa A.
    VanRavenhorst-Bell, Heidi A.
    [J]. FRONTIERS IN PSYCHOLOGY, 2021, 12
  • [4] Test-retest reliability and minimal detectable change scores of twelve functional fitness tests in adults with Down syndrome
    Boer, P. H.
    Moss, S. J.
    [J]. RESEARCH IN DEVELOPMENTAL DISABILITIES, 2016, 48 : 176 - 185
  • [5] Reliability, Validity, and Minimal Detectable Change of Four-Step Stair Climb Power Test in Community-Dwelling Older Adults
    Ni, Meng
    Brown, Lorna G.
    Lawler, Danielle
    Bean, Jonathan F.
    [J]. PHYSICAL THERAPY, 2017, 97 (07): : 767 - 773
  • [6] Test-Retest reliability and preliminary reliable change estimates for Sway Balance tests administered remotely in community-dwelling adults
    Caccese, Jaclyn B.
    Teel, Elizabeth
    Van Patten, Ryan
    Muzeau, Melissa A.
    Iverson, Grant L.
    VanRavenhorst-Bell, Heidi A.
    [J]. FRONTIERS IN DIGITAL HEALTH, 2022, 4
  • [7] The Test-Retest Reliability and Minimal Detectable Change of the FitLight TrainerTM
    Myers, Lauren R.
    Toonstra, Jenny L.
    Cripps, Andrea E.
    [J]. INTERNATIONAL JOURNAL OF ATHLETIC THERAPY & TRAINING, 2022, : 84 - 88
  • [8] Test-retest Reliability Of A 20-sec Stepping Test Movement Displacement In Community-dwelling Older Adults
    Fujita, Eiji
    Takeshima, Nobuo
    Kohama, Takeshi
    Nakagaichi, Masaki
    Kusunoki, Masanobu
    Brechue, William F.
    [J]. MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (09) : 1006 - 1006
  • [9] TEST-RETEST RELIABILITY AND MINIMAL DETECTABLE CHANGE OF THE HEXAGON AGILITY Test
    Beekhuizen, Kristina S.
    Davis, Maurice D.
    Kolber, Morey J.
    Cheng, Ming-Shun S.
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2009, 23 (07) : 2167 - 2171
  • [10] Test-retest reliability and minimal detectable change of the Contextual Memory Test in older adults with and without mild cognitive impairment
    Liao, Wan-wen
    Wu, Ching-yi
    Liu, Chien-Hsiou
    Lin, Szu-hung
    Chiau, Hui-Yan
    Chen, Chia-ling
    [J]. PLOS ONE, 2020, 15 (07):