Quantification of Free Immunoglobulin Light Chains in Urine

被引:1
|
作者
Singh, Gurmukh [1 ,3 ]
Cotter, Thomas [1 ]
Mon, May Ye [1 ]
Xu, Hongyan [2 ]
Bollag, Roni J. [1 ]
机构
[1] Augusta Univ, Med Coll Georgia, Dept Pathol, Augusta, GA USA
[2] Augusta Univ, Med Coll Georgia, Dept Populat Hlth Sci, Augusta, GA USA
[3] Augusta Univ, Med Coll Georgia, Room BI 2008A, Augusta, GA 30912 USA
来源
关键词
MONOCLONAL GAMMOPATHIES; DIAGNOSIS;
D O I
10.1093/jalm/jfad055
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background The serum-free immunoglobulin light chain assay has been recommended as a screening test for monoclonal gammopathy. We evaluated the usefulness of urine free immunoglobulin light concentration for selection of specimens for immunofixation electrophoresis.Methods Using kits from The Binding Site for Freelite (R), we validated examination of urine for measuring free ? and ? light chains. The results of urine free light chain concentrations were evaluated to ascertain if the results could be used to reduce the number of specimens requiring urine protein immunofixation electrophoresis.Results In the 515 specimens examined, there was no evidence of monoclonal gammopathy or history of monoclonal gammopathy in 331. Monoclonal ? or ? light chains were detectable in 42 and 30 specimens, respectively. There was history of ? or ? chain associated monoclonal gammopathy in 62 and 50 patients, respectively. In the 38 monoclonal ? positive urine specimens, with light chain data, ?/? ratio was >5.83 in all specimens. In 27 specimens positive for monoclonal ? light chains, with light chain data, the urine ?/? ratio was > 0.17 in 24 of 27 specimens and > 0.041 in all specimens. In patients without monoclonal gammopathy all specimens had a ?/? ratio of >5.83 or ?/? ratio >0.17.Conclusions The Freelite (R) assay from The Binding Site is suitable for quantification of free light chains in urine. In patients with known history of monoclonal gammopathy, urine immunofixation electrophoresis may be omitted in specimens with ?/? ratio of <5.83 for ? associated lesions and ?/? ratio of <0.041 for ? associated lesions. However, the results do not support using this test for first-time urine testing for monoclonal light chains as it is not predictive of positive result, nor does it exclude a monoclonal light chain in urine.
引用
收藏
页码:1101 / 1114
页数:14
相关论文
共 50 条
  • [1] Immunochemical quantification of free light chains in urine
    Herzum, F
    Renz, H
    Wahl, HG
    CLINICAL CHEMISTRY, 2005, 51 (06) : 1033 - 1035
  • [2] κ and λ urine free light chains: a new method for quantification
    Giussani, Marta
    Ciniselli, Chiara Maura
    Macciotta, Alessandra
    Panella, Rossella
    Verderio, Paolo
    Bonini, Chiara
    Morelli, Daniele
    TUMORI JOURNAL, 2020, 106 (06): : 457 - 463
  • [3] Quantification of immunoglobulin free light chains in cerebrospinal fluid by nephelometry
    Desplat-Jégo, S
    Feuillet, L
    Pelletier, J
    Bernard, D
    Chérif, AA
    Boucraut, J
    JOURNAL OF CLINICAL IMMUNOLOGY, 2005, 25 (04) : 338 - 345
  • [4] Quantification of Immunoglobulin Free Light Chains in CerebroSpinal Fluid by Nephelometry
    Sophie Desplat-jégo
    Lionel Feuillet
    Jean Pelletier
    Dominique Bernard
    André Ali Chérif
    José Boucraut
    Journal of Clinical Immunology, 2005, 25 : 338 - 345
  • [5] Reliability of the Freelite assay for quantification of free light chains in urine
    Herzum, I
    Bruder-Burzlaff, B
    Heinz, R
    Renz, H
    Wahl, HG
    CLINICAL CHEMISTRY, 2004, 50 (06) : A80 - A80
  • [7] Urine and Free Immunoglobulin Light Chains as Analytes for Serodiagnosis of Hantavirus Infection
    Hepojoki, Satu
    Kareinen, Lauri
    Strandin, Tomas
    Vaheri, Antti
    Holthoefer, Harry
    Mustonen, Jukka
    Makela, Satu
    Hedman, Klaus
    Vapalahti, Olli
    Hepojoki, Jussi
    VIRUSES-BASEL, 2019, 11 (09):
  • [8] Immunochemical quantification of free immunoglobulin light chains from an analytical perspective
    Nakano, Takanari
    Miyazaki, Shuichi
    Takahashi, Hidenori
    Matsumori, Akira
    Maruyama, Taro
    Komoda, Tsugikazu
    Nagata, Atsuo
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (05) : 522 - 532
  • [9] Polyclonal versus monoclonal immunoglobulin-free light chains quantification
    Di Noto, Giuseppe
    Cimpoies, Elena
    Dossi, Alessandra
    Paolini, Lucia
    Radeghieri, Annalisa
    Caimi, Luigi
    Ricotta, Doris
    ANNALS OF CLINICAL BIOCHEMISTRY, 2015, 52 (03) : 327 - 336
  • [10] Highly sensitive, automated immunoassay for immunoglobulin free light chains in serum and urine
    Bradwell, AR
    Carr-Smith, HD
    Mead, GP
    Tang, LX
    Showell, PJ
    Drayson, MT
    Drew, R
    CLINICAL CHEMISTRY, 2001, 47 (04) : 673 - 680