Feasibility and Safety of Dual-console Telesurgery with the KangDuo Surgical Robot-01 System Using Fifth-generation and Wired Networks: An Animal Experiment and Clinical Study

被引:12
|
作者
Fan, Shubo [1 ,2 ]
Xu, Weifeng
Diao, Yingzhi [4 ]
Yang, Kunlin [1 ,2 ]
Dong, Jie [3 ]
Qin, Mingwei [5 ]
Ji, Zhigang [3 ]
Shen, Cheng [1 ,2 ]
Zhou, Liqun [1 ,2 ]
Li, Xuesong [1 ,2 ]
机构
[1] Peking Univ, Peking Univ First Hosp, Inst Urol, Dept Urol, 8 Xishiku St, Beijing 100034, Peoples R China
[2] Natl Urol Canc Ctr, Beijing, Peoples R China
[3] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Peking Union Med Coll, Dept Urol, Beijing, Peoples R China
[4] Peking Univ First Hosp, Beijing Miyun Dist Hosp, Miyun Hosp, Dept Urol, Beijing, Peoples R China
[5] Peking Union Med Coll Hosp, Telemed Ctr, Beijing, Peoples R China
来源
关键词
Fifth-generation technology; Partial nephrectomy; Pyeloplasty; Robotics; Telesurgery; Wired network;
D O I
10.1016/j.euros.2022.12.010
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The coronavirus disease 2019 pandemic has drawn attention to telesurgery. Important advances in fifth-generation (5G) mobile telecommunication technology have facilitated the rapid evolution of telesurgery. Previously, only a single console was used in telesurgery; thus, there was the possibility of open or laparoscopic conversion. Furthermore, the 5G network has not been available for regional hospitals in China. From October 2021 to April 2022, dual-console telesurgeries with the KangDuo Surgical Robot-01 (KD-SR-01) system were performed using 5G and wired networks in an animal experiment and clinical study. A partial nephrectomy in a porcine model was performed successfully using a wired network. The console time, warm ischemia time, and control swap time were 69 min, 27 min, and 3 s, respectively. The mean latency time was 130 (range, 60-200) ms. A 32-yr-old male patient successfully underwent a remote pyeloplasty using a series connection of 5G wireless and wired networks. The console time and control swap time were 98 min and 3 s, respectively. The mean latency time was 271 (range, 206-307) ms. In the two studies, data pocket loss was <1%. The results demonstrated that dual-console telesurgery with the KD-SR-01 system is feasible and safe using 5G technology helped in the rapid evolution of telesurgery. Dual-console telesurgery performed with the KD-SR-01 system using 5G and wired networks was shown to be feasible and safe in an animal experiment and clinical study. (c) 2022 Published by Elsevier B.V. on behalf of European Association of Urology. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/ by-nc-nd/4.0/).
引用
收藏
页码:6 / 9
页数:4
相关论文
共 9 条
  • [1] Feasibility and safety of dual-console telesurgery with the KangDuo Surgical Robot-1500 System using fifth-generation and wired networks: an animal experiment and sea-spanning clinical study
    Xu, Liqing
    Shen, Cheng
    Li, Xinfei
    Zhao, Fangzhou
    Huang, Wei
    Yang, Kunlin
    Zhang, Peng
    Du, Yicong
    Fan, Shubo
    Cui, Liang
    Zhou, Liqun
    Li, Xuesong
    MINERVA UROLOGY AND NEPHROLOGY, 2024, 76 (02): : 241 - 246
  • [2] Robot-Assisted Radical Prostatectomy Using the KangDuo Surgical Robot-01 System: A Prospective, Single-Center, Single-Arm Clinical Study
    Kulis, Tomislav
    JOURNAL OF UROLOGY, 2022, 208 (01): : 127 - 127
  • [3] ROBOTIC UROLOGIC SURGERY USING THE KANGDUO-SURGICAL ROBOT-01 SYSTEM: A PROSPECTIVE COHORT STUDY OF 100 CONSECUTIVE CASES
    Xiong, Shengwei
    Fan, Shubo
    Chen, Silu
    Yang, Kunlin
    Zhang, Zhongyuan
    Shen, Cheng
    Zhou, Liqun
    Li, Xuesong
    JOURNAL OF UROLOGY, 2023, 209 : E956 - E957
  • [4] Evaluating the efficacy of telesurgery with dual console SSI Mantra Surgical Robotic System: experiment on animal model and clinical trials
    Srivastava, Sudhir Prem
    Srivastava, Vishwajyoti Pascual
    Singh, Avinesh
    Dwivedi, Suraj
    Batra, Munish
    Gupta, Shivam
    Singh, Sonu
    Kulkarni, Shubhankar Sanjiv
    Paul, Anson
    Kumar, Amit
    Agwan, Manjusha
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [5] Robot-Assisted Radical Nephroureterectomy Using the KangDuo-Surgical Robot-01 System: A Prospective, Single-Center, Single-Arm Clinical Study
    Zuo, Wei
    Li, Zhenyu
    Qi, Tang
    Fan, Shubo
    Li, Zhihua
    Yang, Kunlin
    Zhou, Liqun
    Zhang, Zhongyuan
    Li, Xuesong
    JOURNAL OF ENDOUROLOGY, 2024, 38 (07) : 661 - 667
  • [6] Robot-Assisted Radical Prostatectomy Using the KangDuo Surgical Robot-01 System: A Prospective, Single-Center, Single-Arm Clinical Study COMMENT
    Herrell, S. Duke
    JOURNAL OF UROLOGY, 2022, 208 (01): : 126 - 127
  • [7] Robot-assisted pyeloplasty using a new robotic system, the KangDuo-Surgical Robot-01: a prospective, single-centre, single-arm clinical study
    Fan, Shubo
    Dai, Xiaofei
    Yang, Kunlin
    Xiong, Shengwei
    Xiong, Gengyan
    Li, Zhihua
    Cheng, Sida
    Li, Xinfei
    Meng, Chang
    Guan, Hua
    Huang, Yanbo
    Mu, Li
    Cui, Liang
    Zhou, Liqun
    Li, Xuesong
    BJU INTERNATIONAL, 2021, 128 (02) : 162 - 165
  • [8] Re: Robot-Assisted Pyeloplasty Using a New Robotic System, the KangDuo-Surgical Robot-01: A Prospective, Single-Centre, Single-Arm Clinical Study
    Cadeddu, Jeffrey A.
    JOURNAL OF UROLOGY, 2022, 207 (02): : 448 - 448
  • [9] Robot-Assisted Radical Prostatectomy Using the KangDuo Surgical Robot-01 System: A Prospective, Single-Center, Single-Arm Clinical Study (vol 208, pg 119, 2022)
    Tarr, Phillip I.
    JOURNAL OF UROLOGY, 2022, 208 (03): : 744 - 744