Ultrasound guidance versus landmark guidance for intrathecal baclofen pump refill: A randomized pilot study

被引:1
|
作者
Stone, Shane N. [1 ,2 ,3 ]
Wei, Daniel [1 ,2 ,4 ]
Reger, Christopher [1 ,2 ]
机构
[1] Northwestern Univ, Phys Med & Rehabil, Feinberg Sch Med, Chicago, IL USA
[2] Shirley Ryan AbilityLab, Chicago, IL USA
[3] Northwestern Univ, Phys Med & Rehabil, Feinberg Sch Med, 355 E Erie St, Chicago, IL 60611 USA
[4] Mayo Clin, Phoenix, AZ USA
关键词
RESIDENT; OUTCOMES; IMPACT; PAIN;
D O I
10.1002/pmrj.12982
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Refilling difficult-to-access intrathecal baclofen (ITB) pumps by a trainee can result in longer procedures, more needle punctures, and more frequent attending interventions. Though ultrasound guidance can be used, there has not been an investigation into the impact of ultrasound guidance on refill outcomes.Objective: To determine the feasibility of ultrasound guidance during difficult ITB refills to improve the experience of patients and providers.Design: Nonblinded, randomized controlled trial with crossover element.Setting: Outpatient clinic at a tertiary academic rehabilitation hospital.Participants: Patients =18 years old with historically difficult refills who were scheduled for repeat refills. "Difficult" was defined as body mass index > 30.0, a deep/tilted pump, previously requiring >1 skin puncture, or previously needing special positioning to access.Interventions: Consented participants were randomized into a template-guided group (control) or an ultrasound-guided group (experimental) using a coin flip. Patients were crossed over if (1) a second refill occurred during the study period or (2) the randomized technique failed.Main Outcome Measures: The primary measure was time spent with needle under skin (seconds). Number of needle punctures and needle passes, frequency of attending intervention, pain during and after the procedure, patient satisfaction, and practitioner perceived difficulty were investigated.Results: Seventeen patients underwent 21 refills (12 template guided and 9 ultrasound guided). No patients experienced adverse events. Although without statistically significant difference, the average time in the experimental group was shorter than the control (175 seconds vs 401 seconds), there were fewer episodes of multiple needle punctures (0 vs 2), multiple needle passes (2 vs 5), and attending interventions (0 vs 3) in the experimental group. No significant/clinical difference was found in pain during procedure, pain after procedure, patient satisfaction, or practitioner subjective difficulty.Conclusions: This pilot study demonstrates that ultrasound-guided ITB refills may reduce time spent with the needle in the skin, number of needle punctures, number of needle passes, and frequency of attending intervention during trainee refilling of pumps that are difficult to access.
引用
收藏
页码:1425 / 1430
页数:6
相关论文
共 50 条
  • [1] Ultrasound guidance for intrathecal baclofen pump refill
    Aras, Berke
    Kesikburun, Serdar
    Adiguzel, Emre
    Yilmaz, Bilge
    TURKIYE FIZIKSEL TIP VE REHABILITASYON DERGISI-TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION, 2016, 62 (02): : 182 - 182
  • [2] The use of ultrasound guidance in intrathecal pump refill
    Piracini, Emanuele
    Corso, Ruggero M.
    Byrne, Helen
    Calli, Morena
    Maitan, Stefano
    MINERVA ANESTESIOLOGICA, 2017, 83 (02) : 220 - 221
  • [3] Ultrasound Guidance for Technically Challenging Intrathecal Baclofen Pump Refill Three Cases and Procedure Description
    Maneyapanda, Mithra B.
    Chien, George C. Chang
    Mattie, Ryan
    Amorapanth, Prin
    Reger, Christopher
    McCormick, Zachary L.
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2016, 95 (09) : 692 - 697
  • [4] Subclavian central venous catheters guidance and examination by ultrasound: a randomized controlled study versus landmark method
    S Perbet
    F Grimaldi
    B Pereira
    JM Constantin
    Intensive Care Medicine Experimental, 3 (Suppl 1)
  • [5] Cryobiopsy With Radial UltraSound Guidance (CYRUS) A Pilot Randomized Controlled Study
    Pannu, Jasleen K.
    Roller, Lance J.
    Lentz, Robert J.
    Rickman, Otis B.
    Aboudara, Matthew C.
    Chen, Heidi
    Maldonado, Fabien
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2021, 28 (01) : 21 - 28
  • [6] Ultrasound guidance versus the landmark technique for subclavian vein cannulation in children
    Zeyneloglu, P.
    Celik, C.
    Pirat, A.
    Arslan, G.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 161 - 161
  • [7] Ultrasound guidance versus landmark method for peripheral venous cannulation in adults
    Tada, Masafumi
    Matsumoto, Takashi
    Takeda, Chikashi
    Yamada, Naoki
    Furukawa, Toshi A.
    Watanabe, Norio
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2019, (09):
  • [8] Ultrasound guidance versus landmark method for peripheral venous cannulation in adults
    Tada, Masafumi
    Yamada, Naoki
    Matsumoto, Takashi
    Takeda, Chikashi
    Furukawa, Toshi A.
    Watanabe, Norio
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2022, (12):
  • [9] Intrathecal Baclofen Pump Refill-Related Cardiac Arrest: A Case Report
    Aldalahmeh, Mohammad
    Sanayeh, Elie Bou
    Sadiq, Waleed
    Wei, Chapman
    Chalhoub, Michel
    JOURNAL OF PAIN & PALLIATIVE CARE PHARMACOTHERAPY, 2024,
  • [10] Localization of Salivary Glands for Botulinum Toxin Treatment: Ultrasound Versus Landmark Guidance
    Loens, Sebastian
    Brueggemann, Norbert
    Steffen, Armin
    Baeumer, Tobias
    MOVEMENT DISORDERS CLINICAL PRACTICE, 2020, 7 (02): : 194 - 198