Junctional rhythm during cryoablation for typical atrioventricular nodal reentrant tachycardia

被引:0
|
作者
Nakano, Masahiro [1 ]
Kondo, Yusuke [2 ]
Kajiyama, Takatsugu [1 ]
Nakano, Miyo [2 ]
Ito, Ryo [2 ]
Kitagawa, Mari [2 ]
Sugawara, Masafumi [2 ]
Chiba, Toshinori [2 ]
Ryuzaki, Satoko [2 ]
Yoshino, Yutaka [2 ]
Komai, Yuya [2 ]
Takanashi, Yukiko [2 ]
Kobayashi, Yoshio [2 ]
机构
[1] Chiba Univ, Dept Adv Cardiorhythm Therapeut, Grad Sch Med, 1-8-1 Inohana,Chuo Ku, Chiba, Chiba 2608670, Japan
[2] Chiba Univ, Dept Cardiovasc Med, Grad Sch Med, Chiba, Japan
关键词
cryoablation; junctional rhythm; typical atrioventricular nodal reentrant tachycardia; SLOW-PATHWAY; CATHETER ABLATION; MULTICENTER; AVNRT;
D O I
10.1111/jce.15979
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionCryoablation is being used as an alternative to radiofrequency (RF) ablation for atrioventricular nodal reentrant tachycardia (AVNRT) owing to the lower risk of atrioventricular block (AVB) compared to RF ablation. Junctional rhythm often occurs during successful application of RF ablation for AVNRT. In contrast, junctional rhythm has rarely been reported to occur during cryoablation. This retrospective study evaluated the characteristics of junctional rhythm during cryoablation for typical AVNRT. Methods and ResultsThis retrospective study included 127 patients in whom successful cryoablation of typical AVNRT was performed. Patients diagnosed with atypical AVNRT were excluded. Junctional rhythm appeared during cryofreezing in 22 patients (17.3%). These junctional rhythms appeared due to cryofreezing at the successful site in the early phase within 15 s of commencement of cooling. Transient complete AVB was observed in 10 of 127 patients (7.9%), and it was noted that atrioventricular conduction improved immediately after cooling was stopped in these 10 patients. No junctional rhythm was observed before the appearance of AVB. No recurrence of tachycardia was confirmed in patients in whom junctional rhythm occurred by cryofreezing at the successful site. ConclusionOccurrence of junctional rhythms during cryoablation is not so rare and can be considered a criterion for successful cryofreezing. Furthermore, junctional rhythm may be associated with low risk of recurrent tachycardia.
引用
收藏
页码:1665 / 1670
页数:6
相关论文
共 50 条
  • [1] ORIGIN OF JUNCTIONAL RHYTHM DURING RADIOFREQUENCY ABLATION FOR ATRIOVENTRICULAR NODAL REENTRANT TACHYCARDIA
    BOYLE, NG
    ZARDINI, M
    MONAHAN, KM
    ZEBEDE, J
    SCHUGER, CD
    JOSEPHSON, ME
    CIRCULATION, 1994, 90 (04) : 216 - 216
  • [2] Three-dimensional mapping of junctional beats during atrioventricular nodal reentrant tachycardia cryoablation
    De Ruvo, Ermenegildo
    Coscia, Vincenzo
    Petrungaro, Mattia
    Calo, Leonardo
    JOURNAL OF ARRHYTHMIA, 2022, 38 (05) : 807 - 808
  • [3] Cryoablation of Atrioventricular Nodal Reentrant Tachycardia: A Clinical Review
    De Sisti, Antonio
    Tonet, Joelci
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (02): : 233 - 240
  • [4] Origin of junctional tachycardia during radiofrequency ablation of atrioventricular nodal reentrant tachycardia in man
    Jayachandran, JV
    Miller, JM
    Zipes, DP
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 133A - 133A
  • [5] Absence of junctional rhythm during successful slow-pathway ablation in patients with atrioventricular nodal reentrant tachycardia
    Hsieh, MH
    Chen, SA
    Tai, CT
    Yu, WC
    Chen, YJ
    Chang, MS
    CIRCULATION, 1998, 98 (21) : 2296 - 2300
  • [6] Acute and long-term outcome of cryoablation therapy of typical atrioventricular nodal reentrant tachycardia
    Bastani, Hamid
    Schwieler, Jonas
    Insulander, Per
    Tabrizi, Fariborz
    Braunschweig, Frieder
    Kenneback, Goran
    Drca, Nikola
    Sadigh, Bita
    Jensen-Urstad, Mats
    EUROPACE, 2009, 11 (08): : 1077 - 1082
  • [7] Electrophysiological characteristics of junctional rhythm during ablation of the slow pathway in different types of atrioventricular nodal reentrant tachycardia
    Lee, SH
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (02): : 111 - 118
  • [8] A safe and simple approach to avoid fast junctional rhythm during ablation in patients with atrioventricular nodal reentrant tachycardia
    Tachibana, Motomi
    Banba, Kimikazu
    Matsumoto, Kensuke
    Ohara, Minako
    Nagase, Satoshi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (09) : 1578 - 1585
  • [9] Cryoablation for Presumed Atrioventricular Nodal Reentrant Tachycardia in Pediatric Patients
    Villasenor, Mario
    Schaffer, Michael S.
    Collins, Kathryn K.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (11): : 1319 - 1325
  • [10] Cryoablation versus radiofrequency ablation of atrioventricular nodal reentrant tachycardia
    Santangeli, Pasquale
    Proietti, Riccardo
    Di Biase, Luigi
    Bai, Rong
    Natale, Andrea
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 39 (02) : 111 - 119