AIE-Active Turn-On' Sensors for Highly Selective Detection of Bovine Serum Albumin

被引:1
|
作者
Gawade, Vilas K. [1 ]
Jadhav, Ratan W. [2 ]
Singh, Prabhat K. [3 ,4 ]
Bhosale, Sheshanath V. [1 ]
机构
[1] Cent Univ Karnataka, Sch Chem Sci, Kalaburagi 585367, India
[2] Goa Univ, Sch Chem Sci, Taleigao Plateau 403206, Goa, India
[3] Bhabha Atom Res Ctr, Radiat & Photochem Div, Mumbai 400085, India
[4] Homi Bhabha Natl Inst, Training Sch Complex, Mumbai 400094, India
来源
CHEMISTRYSELECT | 2023年 / 8卷 / 33期
关键词
Aggregation-Induced Emission; Biological probe; Molecular Docking; Selective Sensing of Bovine Serum Albumin; Turn-On molecular recognition; AGGREGATION-INDUCED EMISSION; LARGE STOKES SHIFT; MOLECULAR PROBE; BSA; RECOGNITION; DYE;
D O I
10.1002/slct.202302474
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Tetraphenylethylene (TPE)-based, two molecular 'Turn-On' probes i. e. 4,4',4'',4'''-(ethene-1,1,2,2-tetrayl)tetraphenol (tetrahydroxy-TPE, coded as: TPE-1) 4,4',4'',4'''-(ethene-1,1,2,2-tetrayl)tetraaniline and tetraamino-TPE, coded as: TPE-2) have been successfully reported for the selective detection of bovine serum albumin (BSA) over its other biological competitors. The BSA sensing has been investigated using UV-Vis absorption and fluorescence emission spectroscopy, where the fluorescence of probes tetrahydroxy-TPE and tetra-amino-TPE was significantly enhanced in the presence of BSA. The BSA sensing was also characterized by visual eye detection, where a significant color change of probe tetrahydroxy-TPE and tetra-amino-TPE was observed with BSA. The detection limit for BSA was calculated to be 0.2 nM and 1.41 nM for using probes tetrahydroxy-TPE and tetra-amino-TPE, respectively. The binding constant was observed to be1.8x103 M and 1.4x103 M for probes tetrahydroxy-TPE and tetra-amino-TPE, respectively. A molecular docking study is also performed to investigate the detailed interactions between probes tetrahydroxy-TPE and tetra-aminoTPE with BSA. The lowest binding energy conformation for probes tetrahydroxy-TPE and tetra-amino-TPE was found at 8.1 kcal/mol and 8.2 kcal/mol, respectively.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A highly sensitive “turn-on” fluorescent probe for bovine serum albumin protein detection and quantification based on AIE-active distyrylanthracene derivative
    WANG ZiLong
    MA Ke
    XU Bin
    LI Xing
    TIAN WenJing
    中国科学:化学, 2013, 43 (09) : 1212 - 1212
  • [2] A highly sensitive "turn-on" fluorescent probe for bovine serum albumin protein detection and quantification based on AIE-active distyrylanthracene derivative
    Wang ZiLong
    Ma Ke
    Xu Bin
    Li Xing
    Tian WenJing
    SCIENCE CHINA-CHEMISTRY, 2013, 56 (09) : 1234 - 1238
  • [3] A highly sensitive “turn-on” fluorescent probe for bovine serum albumin protein detection and quantification based on AIE-active distyrylanthracene derivative
    WANG ZiLong
    MA Ke
    XU Bin
    LI Xing
    TIAN WenJing
    Science China(Chemistry), 2013, (09) : 1234 - 1238
  • [4] A highly sensitive “turn-on” fluorescent probe for bovine serum albumin protein detection and quantification based on AIE-active distyrylanthracene derivative
    WANG ZiLong
    MA Ke
    XU Bin
    LI Xing
    TIAN WenJing
    Science China(Chemistry), 2013, 56 (09) : 1234 - 1238
  • [5] A highly sensitive “turn-on” fluorescent probe for bovine serum albumin protein detection and quantification based on AIE-active distyrylanthracene derivative
    ZiLong Wang
    Ke Ma
    Bin Xu
    Xing Li
    WenJing Tian
    Science China Chemistry, 2013, 56 : 1234 - 1238
  • [6] Preparation a novel pyrene-based AIE-active ratiometric turn-on fluorescent probe for highly selective and sensitive detection of Hg2+
    Ma, Jie
    Xiao, Yao
    Zhang, Cuihong
    Zhang, Manman
    Wang, Qingyang
    Zheng, Weiguo
    Zhang, Shuping
    MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS, 2020, 259
  • [7] An AIE-active fluorescence turn-on bioprobe mediated by hydrogen-bonding interaction for highly sensitive detection of hydrogen peroxide and glucose
    Song, Zhegang
    Kwok, Ryan T. K.
    Ding, Dan
    Nie, Han
    Lam, Jacky W. Y.
    Liu, Bin
    Tang, Ben Zhong
    CHEMICAL COMMUNICATIONS, 2016, 52 (65) : 10076 - 10079
  • [8] An AIE-active "turn-off" fluorescent sensor for highly selective and sensitive detection of Cu2+ions
    Niu, Xiaoling
    Zhang, Hong
    Wu, Xiaojing
    Zhu, Shengbo
    Liu, Yongliang
    Tian, Min
    JOURNAL OF MOLECULAR STRUCTURE, 2022, 1264
  • [9] A Turn-On Sensor for Highly Sensitive and Selective Detect Heparin in Human Serum Albumin
    Huang, Cuiping
    Cao, Jian
    Liu, Mingming
    Tu, Yajing
    Zhang, Meijuan
    Zheng, Junying
    CHEMISTRYSELECT, 2022, 7 (15):
  • [10] Reversible and Turn-On Fluorescence Detection of Phosphate in Aqueous Solution and Living Cell Imaging by Supramolecular Metallacycles with AIE-Active Ligands
    Kou, Ya-Lan
    Tong, Jin
    Meng, Cong
    Yuan, Qing
    Wang, Ji
    Yu, Shu-Yan
    ACS APPLIED MATERIALS & INTERFACES, 2023, 15 (34) : 40828 - 40838