Damping Identification From Subsea Logger Axial Riser Response Data

被引:0
|
作者
Lim, Hyeonguk [1 ]
McNeill, Scot [1 ]
Kluk, Daniel [1 ]
Stahl, Matthew [1 ]
Puskarskij, Konstantin [2 ]
Hansen, Kristian [3 ]
机构
[1] Stress Engn Serv Inc, Houston, TX 77041 USA
[2] Copenhagen Energy Partners, Copenhagen, Denmark
[3] Maersk Drilling, Lyngby, Denmark
来源
SPE JOURNAL | 2023年 / 28卷 / 06期
关键词
Compendex;
D O I
10.2118/212496-PA
中图分类号
TE [石油、天然气工业];
学科分类号
0820 ;
摘要
For decades, it has been known that, as drilling riser deployment depths increase, the potential for excessive hookload response will also increase. Using data collected from a drilling riser deployed to a record-setting water depth, nearly 12,000 ft, this paper provides insight that significantly reduces uncertainty about the severity of this resonant response.The typical drilling riser and blowout preventer (BOP) stack, disconnected from the wellhead, has its first axial resonant period at approximately 1 second for every 2,000 ft of deployed length, thus 5 seconds for 10,000 ft, 6 seconds for 12,000 ft, and so on. Therefore, vessel heave response can incite a significant, adverse axial resonant condition in very deep water. Damping reduces resonant response. Historically, the true amount of damping has been uncertain, and damping has been applied in the form of hydrodynamic drag. This typically produces a predicted response with total damping that is well under 1% of critical. This can lead to the prediction of a large dynamic hookload that can produce significant restrictions on riser configuration (running weight) and seastate for BOP stack deployment as well as storm hang -off of the riser and lower marine riser package (LMRP).A recent drilling riser deployment to the record-setting water depth of 11,903 ft produced a unique opportunity to collect high-quality data that reduces damping uncertainty. This paper describes damping ratio and natural frequency identification for the first few axial riser modes for this deployment. The data were collected during deployment and retrieval using subsea vibration data loggers (SVDLs) installed on the BOP stack, drillship, and riser. These measurements reveal damping that is between 2% and 3% of critical. This result can be used to provide more accurate predictions of dynamic hookload response.
引用
收藏
页码:3239 / 3251
页数:13
相关论文
共 50 条
  • [1] IDENTIFICATION OF NATURAL FREQUENCIES AND MODAL DAMPING RATIOS FROM RESPONSE DATA
    MICHALOPOULOS, CD
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1976, 60 : S74 - S74
  • [2] Interpreting data on marine riser response behavior using system identification
    Niedzwecki, JM
    Pierre-Yves, FASCE
    Liagre, F
    DEEPWATER MOORING SYSTEMS: CONCEPTS, DESIGN, ANALYSIS AND MATERIALS, 2003, : 316 - 319
  • [3] Identification of nonlinear viscous damping and Coulomb friction from the free response data
    Wu, Ziying
    Liu, Hongzhao
    Liu, Lilan
    Yuan, Daning
    JOURNAL OF SOUND AND VIBRATION, 2007, 304 (1-2) : 407 - 414
  • [4] Subsea release of oil from a riser: An ecological risk assessment
    Nazir, Muddassir
    Khan, Faisal
    Amyotte, Paul
    Sadiq, Rehan
    RISK ANALYSIS, 2008, 28 (05) : 1173 - 1196
  • [5] FROM SUBSURFACE TO RISER-AN INTEGRATED APPROACH TO SUBSEA SURVEILLANCE
    Machin, Jon
    PROCEEDINGS OF THE ASME 29TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, 2010, VOL 1, 2010, : 495 - 502
  • [6] Development of a Non-Cloggable Subsea Data Logger for Harsh Turbidity Current Monitoring
    Bradley, Luke J.
    Ruffell, Sean C.
    Talling, Peter J.
    Wright, Nick G.
    OCEANS 2023 - LIMERICK, 2023,
  • [7] Nonlinear damping identification from transient data
    Smith, CB
    Wereley, NM
    AIAA JOURNAL, 1999, 37 (12) : 1625 - 1632
  • [8] Nonlinear damping identification from transient data
    Smith, CB
    Wereley, NH
    SMART STRUCTURES AND MATERIALS 1999: PASSIVE DAMPING AND ISOLATION, 1999, 3672 : 2 - 19
  • [9] A method for damping matrix identification using frequency response data
    Pradhan, S.
    Modak, S. V.
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2012, 33 : 69 - 82
  • [10] DATA LOGGER BUILT FROM MODULES
    不详
    CONTROL ENGINEERING, 1969, 16 (02) : 67 - &