AIE-based cyclodextrin metal-organic frame material for fluorescence detection of nitrofuran and tetracycline antibiotics in aqueous solution

被引:14
|
作者
Sun, Xuezhi [1 ]
Qiao, Yunfan [1 ]
Zhang, Min [2 ]
Cheng, Yongzhe [1 ]
Ning, Fanghong [3 ]
Zhang, Hongyang [1 ]
Hu, Ping [1 ]
机构
[1] East China Univ Sci & Technol, Sch Chem & Mol Engn, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China
[2] East China Univ Sci & Technol, Shanghai Frontiers Sci Ctr Optogenet Tech Cell Met, Sch Pharm, Shanghai 200237, Peoples R China
[3] East China Univ Sci & Technol, Sch Biotechnol, Shanghai 200237, Peoples R China
关键词
Antibiotic; cyclodextrin cross -linked MOF; Tetraphenylethylene; Honey; CD-MOF; RESIDUES; LIQUID; IMMUNOASSAY;
D O I
10.1016/j.microc.2023.108687
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The problem of antibiotic residues is very serious and is harmful to the ecological environment and the human body. We have developed a method for the rapid detection of antibiotics in water samples. Firstly, we prepared a fluorescent material (TPE@CLMOF) with cyclodextrin cross-linked MOF (CLMOF) and tetraphenylethylene (TPE) using a simple way. Due to diphenyl carbonate cross-linking, the fluorescent MOF can glow stably in water. Compared with TPE (40.1%), the absolute quantum yield of TPE@CLMOF increases to 63.2%. The fluorescence of TPE@CLMOF can be selectively quenched by Nitrofurans (NFs) and Tetracyclines (TCs) antibiotics in water. The detection limits of nitrofurazone, nitrofurantoin and chlortetracycline are 0.11, 0.13 and 0.16 mu M, respectively. We have studied the adsorption of nitrofurazone, nitrofurantoin and chlortetracycline in TPE@CLMOF and the Langmuir adsorption model and pseudo-second-order kinetic model were established. The maximum adsorption capacity is 223, 209 and 185 mg g(-1), respectively. We also proposed a dual quenching mechanism of electron transfer and internal filtration effect, which is verified by quantum chemical calculations and experiments. Finally, the TPE@CLMOF was successfully used as a fluorescent sensor for the determination of antibiotic spiked honey samples.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] A Stable Viologen-Based Metal-Organic Framework for Fluorescence Detection of Nitroaromatics and Nitrofuran Antibiotics in Water
    Zhang, Shi
    Zhou, Yudie
    Tuo, Anna
    Chen, Shufan
    Zhang, Qingfu
    Zhang, Xu
    Xiong, Kecai
    Gai, Yanli
    CRYSTAL GROWTH & DESIGN, 2025, 25 (03) : 494 - 501
  • [2] Visual detection of tetracycline antibiotics with the turned on fluorescence induced by a metal-organic coordination polymer
    Leng, Fei
    Zhao, Xi Juan
    Wang, Jian
    Li, Yuan Fang
    TALANTA, 2013, 107 : 396 - 401
  • [3] AIE-Photoactive Metal-Organic Framework for the Efficient Elimination of Cr(VI) and Tetracycline in an Aqueous Solution
    Mi, Shengyong
    Wang, Lishan
    Guo, Huadong
    Su, Yanan
    Wang, Song
    Xu, Jinqiang
    Cao, Jiaping
    Guo, Xianmin
    CRYSTAL GROWTH & DESIGN, 2023, 24 (01) : 405 - 413
  • [4] Stable Metal-Organic Frameworks for Fluorescent Detection of Tetracycline Antibiotics
    Liu, Lu
    Chen, Qiang
    Lv, Jie
    Li, Yaping
    Wang, Kecheng
    Li, Jian-Rong
    INORGANIC CHEMISTRY, 2022, 61 (20) : 8015 - 8021
  • [5] Heteronuclear metal-organic framework-based fluorescent sensor for the detection of tetracycline antibiotics
    Wang, Cong
    Ren, Guojian
    Zhou, Sihui
    Yang, Yonghang
    Sun, Ahui
    Fang, Yu
    Guo, Dong-Yu
    Pan, Qinhe
    APPLIED ORGANOMETALLIC CHEMISTRY, 2022, 36 (08)
  • [6] Highly Emissive Metal-Organic Frameworks for Sensitive and Selective Detection of Nitrofuran and Quinolone Antibiotics
    Cong, Zhenzhong
    Song, Zhenfeng
    Ma, Yunxiao
    Zhu, Mingchang
    Zhang, Ying
    Wu, Shuangyan
    Gao, Enjun
    CHEMISTRY-AN ASIAN JOURNAL, 2021, 16 (13) : 1773 - 1779
  • [7] Tailoring the Fluorescence of AIE-Active Metal-Organic Frameworks for Aqueous Sensing of Metal Ions
    Li, Qiyang
    Wu, Xiuju
    Huang, Xiaoli
    Deng, Yangjun
    Chen, Nanjian
    Jiang, Dandan
    Zhao, Lili
    Lin, Zhihua
    Zhao, Yonggang
    ACS APPLIED MATERIALS & INTERFACES, 2018, 10 (04) : 3801 - 3809
  • [8] Ratiometric fluorescence detection of tetracycline antibiotic based on a polynuclear lanthanide metal-organic framework
    Li, Runxian
    Wang, Wenjing
    El-Sayed, M. El-Sayed
    Su, Kongzhao
    He, Pingli
    Yuan, Daqiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 330
  • [9] Stable Europium(III) Metal-Organic Framework Fluorescence Probe for Intelligent Visualization Detection of Gossypol and Nitrofuran Antibiotics in Real Samples
    Su, Yu
    Guo, Yichen
    Wu, Qi
    Wang, Linxia
    Wang, Yifei
    Yang, Guoping
    Zhang, Wenyan
    Wang, Yaoyu
    INORGANIC CHEMISTRY, 2024, 63 (32) : 15134 - 15143
  • [10] Ancillary ligand enabled structural and fluorescence diversity in metal-organic frameworks: application for the ultra-sensitive detection of nitrofuran antibiotics
    Lei, Zhen
    Hu, Lei
    Yu, Zi-Hao
    Yao, Qiu-Yang
    Chen, Xi
    Li, Hao
    Liu, Rong-Mei
    Li, Chuan-Ping
    Zhu, Xian-Dong
    INORGANIC CHEMISTRY FRONTIERS, 2021, 8 (05): : 1290 - 1296