Hemodynamics of different configurations of the left subclavian artery parallel stent graft for thoracic endovascular aortic repair

被引:2
|
作者
Che, Yue [1 ]
Zhao, Jiawei [2 ]
Zhang, Xuelan [1 ,3 ]
Luo, Mingyao [2 ,4 ]
Cao, Xiran [1 ]
Zheng, Liancun [1 ]
Shu, Chang [2 ,5 ]
机构
[1] Univ Sci & Technol Beijing, Sch Math & Phys, Beijing 100083, Peoples R China
[2] Chinese Acad Med Sci & Peking Union Med Coll, Fuwai Hosp, Dept Vasc Surg, Beijing 100037, Peoples R China
[3] Univ Sci & Technol Beijing, Sch Energy & Environm Engn, Beijing 10083, Peoples R China
[4] Kunming Med Univ, Fuwai Yunnan Cardiovasc Hosp, Affiliated Cardiovasc Hosp, Dept Vasc Surg, Kunming 650102, Peoples R China
[5] Cent South Univ, Xiangya Hosp 2, Dept Vasc Surg, 139 Renmin Rd, Changsha 410011, Peoples R China
基金
中国博士后科学基金;
关键词
Hemodynamics; Parallel stent graft; Computational fluid dynamics; Postoperative complication; CLINICAL-PRACTICE-GUIDELINES; BLOOD-FLOW; DISSECTION; ARCH; SOCIETY; STROKE; RISK;
D O I
10.1016/j.cmpb.2023.107741
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: Parallel (chimney and periscope) graft technique is an effective approach for left subclavian artery (LSA) reconstruction in patients treated by thoracic endovascular aortic repair (TEVAR) for the inadequate landing zone. However, certain stent graft (SG) configurations may promote thrombosis and reduce distal blood flow, increasing risks of cerebral infarction and reintervention.Methods: In this paper, we first attempt to systematically evaluate the hemodynamic performances of different parallel graft techniques as potential determinants of complication risks. Based on the patient-specific 3D aortic geometry undergoing parallel graft technique, fifteen models in total for five kinds of LSA branched SG con-figurations (Forward, Backward, Extended, Elliptical and Periscopic) were designed virtually, and the hemo-dynamic discrepancies between them were analyzed by computational fluid dynamics. Results: Results show that flow rate of patients undergoing periscope technique reduces by half compared with chimney technique, suggesting that periscope SG may cause more serious flow obstruction to LSA, leading to stroke. For chimney stent structure, the extension length 0has little influence on energy loss and other param-eters. Conversely, hemodynamic differences between the retrograde curvature and the antegrade curvature are significant (time average WSS: 47.07%), so the retrograde curvature might prompt SG displacement. Further-more, the flatter chimney SG induces more aggressive hemodynamic forces, among which the difference of the maximum WSS between the flatter SG and nearly round SG reaches 65.56%, leading to the greater risk of vascular wall damage.Conclusions: Results obtained might provide suggestions for physicians to formulate appropriate parallel graft technique schemes in TEVAR.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Haemodynamics of Different Configurations of a Left Subclavian Artery Stent Graft for Thoracic Endovascular Aortic Repair
    Tricarico, Rosamaria
    Tran-Son-Tay, Roger
    Laquian, Liza
    Scali, Salvatore T.
    Lee, Teng-Chun
    Beck, Adam W.
    Berceli, Scott A.
    He, Yong
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2020, 59 (01) : 7 - 15
  • [2] Influence of Left Subclavian Artery Stent Graft Geometry on Blood Hemodynamics in Thoracic Endovascular Aortic Repair
    Xue, Song
    Lu, Tiandong
    Hu, Wenqing
    Xia, Zeyang
    Zhang, Jun
    Lu, Xinwu
    Xiong, Jing
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2025, 147 (02):
  • [3] Effects of in situ fenestration stent-graft of left subclavian artery on the hemodynamics after thoracic endovascular aortic repair
    Qiao, Yonghui
    Mao, Le
    Ding, Ying
    Fan, Jianren
    Luo, Kun
    Zhu, Ting
    VASCULAR, 2019, 27 (04) : 369 - 377
  • [4] Handmade stent graft fenestration to preserve left subclavian artery in thoracic endovascular aortic repair
    Kuo, Huey-Shiuan
    Huang, Jih-Hsin
    Chen, Jer-Shen
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (03) : 587 - 594
  • [5] Intentional coverage of the left subclavian artery during endovascular stent graft repair for thoracic aortic disease
    Caronno, R.
    Piffaretti, G.
    Tozzi, M.
    Lomazzi, C.
    Rivolta, N.
    Castelli, P.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (06): : 915 - 918
  • [6] Intentional coverage of the left subclavian artery during endovascular stent graft repair for thoracic aortic disease
    R. Caronno
    G. Piffaretti
    M. Tozzi
    C. Lomazzi
    N. Rivolta
    P. Castelli
    Surgical Endoscopy And Other Interventional Techniques, 2006, 20
  • [7] Impact of Left Subclavian Artery Revascularization Before Thoracic Endovascular Aortic Repair on Cerebrovascular Hemodynamics
    Kamman, Arnoud V.
    Eliason, Jonathan L.
    Nauta, Foeke J.
    Williams, David M.
    Yang, Bo
    Moll, Frans L.
    Trimarchi, Santi
    Eagle, Kim A.
    Patel, Himanshu J.
    JOURNAL OF VASCULAR SURGERY, 2016, 64 (03) : 867 - 867
  • [8] Revascularisation of the left subclavian artery for thoracic endovascular aortic repair
    Hajibandeh, Shahin
    Hajibandeh, Shahab
    Antoniou, Stavros A.
    Torella, Francesco
    Antoniou, George A.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (04):
  • [9] In Situ Laser Stent Graft Fenestration of the Left Subclavian Artery for Thoracic Endovascular Repair of Type B Aortic Dissection
    Lu, Xinwu
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E49 - E49
  • [10] Spinal ischaemia after thoracic endovascular aortic repair with left subclavian artery sacrifice: is there a critical stent graft length?
    Kari, Fabian A.
    Saravi, Babak
    Krause, Sonja
    Puttfarcken, Luisa
    Wittmann, Karin
    Foerster, Katharina
    Rylski, Bartosz
    Maier, Sven
    Goebel, Ulrich
    Siepe, Matthias
    Czerny, Martin
    Beyersdorf, Friedhelm
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (02) : 385 - 391