Effect of abutment tooth location on the accuracy of digital impressions obtained using an intraoral scanner for removable partial dentures

被引:1
|
作者
Sakamoto, Kazuki [1 ]
Wada, Junichiro [1 ,2 ,3 ,5 ]
Arai, Yuki [1 ,4 ]
Hayama, Hironari [1 ]
Ishioka, Yurika [1 ]
Kim, Eung-Yeol [1 ]
Kazama, Ryunosuke [1 ]
Toyoshima, Yusuke [1 ]
Wakabayashi, Noriyuki [1 ]
机构
[1] Tokyo Med & Dent Univ TMDU, Grad Sch, Dept Adv Prosthodont, Tokyo, Japan
[2] Univ Turku, Inst Dent, Dept Biomat Sci, Turku, Finland
[3] Univ Turku, Inst Dent, Turku Clin Biomat Ctr TCBC, Turku, Finland
[4] Univ Texas Hlth Sci Ctr Houston, Dept Orthodont, Sch Dent, Houston, TX USA
[5] Tokoyo Med & Dent Univ TMDU, Grad Sch, Adv Prosthodont, 1-5-45 Yushima,Bunkyo ku, Tokyo 1138549, Japan
关键词
Accuracy; Digital impression; Intraoral scanner; Removable partial denture; Trueness; PRECISION; CAD/CAM;
D O I
10.2186/jpr.JPR_D_22_00201
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:To verify the effect of abutment tooth location on the accuracy of digital impressions obtained using an intraoral scanner (IOS) for removable partial dentures (RPDs).Methods: The target abutment teeth included the left first premolar (#34), second molar (#37), and right second premolar (#45) in a mandibular Kennedy class II model and the left and right second molars (#37, #47) in a class III model. Only #37 was isolated from the remaining teeth by the mucosal area in both models. Digital impressions were obtained using a desktop scanner (reference data) and an IOS (IOS data; scanning origin #37; n=10). The general trueness based on the entire model superimposition (TG), local trueness (TL) of an individual tooth, and dimensional accuracy (coordinate and linear accuracy) of the IOS data of the target abutment teeth were compared (alpha=0.05).Results: In both models, #37 showed significantly inferior TG (P<0.01), superior TL (P<0.01), and mesial coordinate displace-ment (P<0.01 and P<0.05 in class II and III models, respectively). Intra-model comparisons showed that #45 in the class II model and #47 in the class III model had significantly inferior linear accuracy (P<0.05 and P<0.01, respectively) and buccal coordinate displacement (P<0.05 and P<0.01, respectively) compared with the other target teeth.Conclusions: In digital impressions of RPDs, isolation of abutment teeth by mucosal areas can reduce general trueness based on the entire dental arch and mesial tooth displacement, whereas increased distance from the scanning origin can adversely affect local trueness and dimensional accuracy.
引用
收藏
页码:531 / 538
页数:8
相关论文
共 50 条
  • [1] Effect of Scanning Origin Location on Data Accuracy of Abutment Teeth Region in Digital Impression Acquired Using Intraoral Scanner for Removable Partial Denture: A Preliminary In Vitro Study
    Kim, Eung-Yeol
    Wada, Junichiro
    Sakamoto, Kazuki
    Ishioka, Yurika
    Arai, Yuki
    Murakami, Natsuko
    Yamazaki, Toshiki
    Hayama, Hironari
    Utsumi, Miona
    Inukai, Shusuke
    Wakabayashi, Noriyuki
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (24)
  • [2] IMPRESSION DISTORTION FROM ABUTMENT TOOTH INCLINATION IN REMOVABLE PARTIAL DENTURES
    JASIM, FA
    BRUDVIK, JS
    NICHOLLS, JI
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1985, 54 (04): : 532 - 538
  • [3] EFFECTS OF REMOVABLE PARTIAL DENTURES ON ABUTMENT TOOTH MOBILITY - CLINICAL STUDY
    GOODKIND, RJ
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1973, 30 (02): : 139 - 145
  • [4] ABUTMENT TOOTH AND BASE MOVEMENT WITH ATTACHMENT RETAINED REMOVABLE PARTIAL DENTURES
    FEINGOLD, GM
    GRANT, AA
    JOHNSON, W
    [J]. JOURNAL OF DENTISTRY, 1988, 16 (06) : 264 - 268
  • [5] Accuracy of an intraoral digital scanner in tooth color determination
    Rutkunas, Vygandas
    Dirse, Julius
    Bilius, Vytautas
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (02): : 322 - 329
  • [6] THE EFFECT OF FIXED AND REMOVABLE PARTIAL DENTURES ON THE PERIODONTIUM OF ABUTMENT TEETH
    SZETO, BK
    RISSIN, L
    KAPUR, KK
    PRESTON, S
    DOUGLASS, CW
    [J]. GERONTOLOGIST, 1980, 20 (05): : 210 - 210
  • [7] The accuracy of a novel 3D digital evaluation method of intraoral fitness for removable partial dentures
    Yoon, Jung-min
    Liu, Yunsong
    Liu, Yushu
    Sun, Yuchun
    Ye, Hongqiang
    Zhou, Yongsheng
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 144
  • [8] The effect of removable partial dentures on periodontal health of abutment and non-abutment teeth
    Zlataric, DK
    Celebic, A
    Valentic-Peruzovic, M
    [J]. JOURNAL OF PERIODONTOLOGY, 2002, 73 (02) : 137 - 144
  • [9] Accuracy of CAD/CAM Digital Impressions with Different Intraoral Scanner Parameters
    Chiu, Asher
    Chen, Yen-Wei
    Hayashi, Juri
    Sadr, Alireza
    [J]. SENSORS, 2020, 20 (04)
  • [10] Accuracy of single-abutment digital cast obtained using intraoral and cast scanners
    Lee, Jae-Jun
    Jeong, Il-Do
    Park, Jin-Young
    Jeon, Jin-Hun
    Kim, Ji-Hwan
    Kim, Woong-Chul
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (02): : 253 - 259