Use of near-infrared spectroscopy for the online monitoring of natural gas composition (hydrocarbons, water and CO2 content) at high pressuree

被引:2
|
作者
Torres, Larissa F. [1 ]
Damascena, Moema A. [1 ]
Alves, Matheus M. A. [1 ]
Santos, Klebson S. [1 ]
Franceschi, Elton [1 ,2 ]
Dariva, Claudio [1 ,2 ]
Barros, Vinicius A. [3 ]
Melo, Darley C. [3 ]
Borges, Gustavo R. [1 ,2 ]
机构
[1] Inst Tecnol & Pesquisa ITP, Nucleo Estudo Sistemas Coloidais NUESC, Ave Murilo Dantas 300, BR-49032490 Aracaju, Brazil
[2] Univ Tiradentes UNIT, PEP, Ave Murilo Dantas 300, BR-49032490 Aracaju, Brazil
[3] Petr Brasileiro S A PETROBRAS, Leopoldo Americo Miguez Mello Res & Dev Ctr CENPES, Ave Horacio Macedo,950 Ilha Fundao, BR-21941915 Rio De Janeiro, Brazil
关键词
Natural gas; Near infrared spectroscopy; Partial least squares; Cubic plus association equation of state; VAPOR-LIQUID-EQUILIBRIUM; EQUATION-OF-STATE; CARBON-DIOXIDE; PHASE-BEHAVIOR; METHANE; SOLUBILITY; ETHANE; MIXTURES; ADSORPTION; NITROGEN;
D O I
10.1016/j.vibspec.2024.103653
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The natural gas production from Brazilian pre-salt fields imposed new challenges for petrochemical industry. Actual treatment facilities are not adequate for this new scenario and studies have been conducted to apply new adsorbents materials and membranes for water and CO2 removal from natural gas at high pressures. To better develop such investigations, sensors for on -line monitoring of natural gas properties like CO2 and water content are important, since their presence affects the quality of the final product. Near infrared (NIR) spectroscopy associated to chemometric models (partial least squares) were employed for on -line monitoring of representative natural gas systems (methane/CO2, methane/water and methane/CO2/water) and a real natural gas at temperature and pressure ranges from 20 to 60 C-degrees and 10 to 200 bar, respectively, water content up to gas saturation and CO2 content up to 50 wt%. Water solubility values used as reference for NIR Spectrometer calibration in model systems were taken from the literature and for real natural gas calculated with Cubic Plus Association (CPA) Equation of State (EoS), while CO2 content was experimentally controlled aiming to calibrate the chemometric models in the full range of pressure and temperature. Several strategies were adopted for the chemometric model's development to obtain the best correlation between NIR spectra and experimental data. Results indicate good correlation in both calibration and validation steps attaining linear correlation coefficients (R-2) higher than 0.96 for all systems investigated. The proposed methodology is a potential tool for on -line monitoring of natural gas composition, including CO2 and water content, at high-pressures and can be applied at petrochemical industries or in laboratories, dispensing sampling or any sample preparation.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Monitoring of CO2 Absorption Solvent in Natural Gas Process Using Fourier Transform Near-Infrared Spectrometry
    Nurida, Mohd Yusop
    Norfadilah, Dolmat
    Aishah, Mohd Rozaiddin Siti
    Phak, Chan Zhe
    Saleh, Syafiqa M.
    [J]. INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 2020
  • [2] FEASIBILITY OF ONLINE MONITORING OF THE BTU CONTENT OF NATURAL-GAS WITH A NEAR-INFRARED FIBER OPTIC-SYSTEM
    BROWN, CW
    LO, SC
    [J]. APPLIED SPECTROSCOPY, 1993, 47 (06) : 812 - 815
  • [3] Near-Infrared Spectroscopic Study of a Water-in-Supercritical CO2 Microemulsion as a Function of the Water Content
    Takebayashi, Yoshihiro
    Sagisaka, Masanobu
    Sue, Kiwamu
    Yoda, Satoshi
    Hakuta, Yukiya
    Furuya, Takeshi
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 2011, 115 (19): : 6111 - 6118
  • [4] Use of Natural Gas with High CO2 Content in an Integrated Industrial Park
    Norstebo, Vibeke Staerkebye
    Midthun, Kjetil Trovik
    Bjorkvoll, Thor Harald
    Kolbeinsen, Leiv
    [J]. ISIJ INTERNATIONAL, 2012, 52 (08) : 1439 - 1446
  • [5] On-chip near-infrared spectroscopy of CO2 using high resolution plasmonic filter array
    Chong, Xinyuan
    Li, Erwen
    Squire, Kenneth
    Wang, Alan X.
    [J]. APPLIED PHYSICS LETTERS, 2016, 108 (22)
  • [6] EVALUATION OF CEREBROVASCULAR CO2 REACTIVITY IN PEDIATRIC COMATOSE PATIENTS BY NEAR-INFRARED SPECTROSCOPY
    KONDO, Y
    MIYASAKA, K
    [J]. ANESTHESIOLOGY, 1994, 81 (3A) : A342 - A342
  • [7] STUDY ON PHASE BEHAVIOR OF NATURAL GAS WITH HIGH CO2 CONTENT
    Hou, Zhaokai
    Yan, Tie
    Li, Zhaoxuan
    Feng, Jinyu
    Sun, Shihui
    Yuan, Yuan
    [J]. FRESENIUS ENVIRONMENTAL BULLETIN, 2019, 28 (2A): : 1325 - 1329
  • [8] Integrated near-infrared QEPAS sensor based on a 28 kHz quartz tuning fork for online monitoring of CO2 in the greenhouse
    Liu, Yihua
    Lin, Haoyang
    Montano, Baiyang Antonio Zhou
    Zhu, Wenguo
    Zhong, Yongchun
    Kan, Ruifeng
    Yuan, Bin
    Yu, Jianhui
    Shao, Min
    Zheng, Huadan
    [J]. PHOTOACOUSTICS, 2022, 25
  • [9] Near-infrared spectroscopic investigation of water in supercritical CO2 and the effect of CaCl2
    Wang, Zheming
    Felmy, Andrew R.
    Thompson, Christopher J.
    Loring, John S.
    Joly, Alan G.
    Rosso, Kevin M.
    Schaef, Herbert T.
    Dixon, David A.
    [J]. FLUID PHASE EQUILIBRIA, 2013, 338 : 155 - 163
  • [10] Near-infrared-featured broadband CO2 reduction with water to hydrocarbons by surface plasmon
    Canyu Hu
    Xing Chen
    Jingxiang Low
    Yaw-Wen Yang
    Hao Li
    Di Wu
    Shuangming Chen
    Jianbo Jin
    He Li
    Huanxin Ju
    Chia-Hsin Wang
    Zhou Lu
    Ran Long
    Li Song
    Yujie Xiong
    [J]. Nature Communications, 14