Evaluation of Inter-Laboratory Comparison Results: Representative Examples

被引:2
|
作者
Frahm, Enrico [1 ]
Wright, John [2 ]
机构
[1] Phys Tech Bundesanstalt, Dept Fluid Flow 1 5, Bundesallee 100, D-38116 Braunschweig, Germany
[2] NIST, 100 Bur Dr, Gaithersburg, MD 20899 USA
关键词
Inter-laboratory comparison; Transfer standard uncertainty; En criterion; Conclusiveness criteria; Probability approach;
D O I
10.1016/j.measurement.2023.113723
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The primary purpose of inter-laboratory comparisons is to verify the CMC claims of the participating labora-tories. The most commonly used evaluation criterion, the normalized error |Eni|, has flaws, particularly if the comparison uncertainty ucomp,i is large relative to the reference standards being compared. According to the recommendations of CIPM Working Group for Fluid Flow, the uncertainty ucomp,i should be considered by including the uncertainty of the transfer standard and the repeatability of the calibrations. A review of previous comparison reports shows the importance of this task for many other measurands beside the field of fluid flow. In this paper, we propose the use of comparison uncertainty ucomp,i as a better tool for assessing the power of the comparison. We applied the comparison evaluation criteria to recent comparison results to illustrate their benefits over the |Eni|<= 1 criterion. A probability-based approach evaluates the comparison results and we recommend its usage in future comparisons.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Reviving the inter-laboratory comparison measurement results
    Sanjid, Mahammed Arif
    Ghoshal, Sanjoy K.
    Sen, Mrinal
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2020, 42 (04) : 823 - 831
  • [2] INAA laboratory results evaluation of inter-laboratory analysis test
    Mohamed, Nader M. A.
    El-Nor, Asmaa G. Abo
    Soliman, Mohamed
    Aal, Ahmed A. Abdel
    Shaat, M. K.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2010, 285 (02) : 321 - 329
  • [3] INAA laboratory results evaluation of inter-laboratory analysis test
    Nader M. A. Mohamed
    Asmaa G. Abo El-Nor
    Mohamed Soliman
    Ahmed A. Abdel Aal
    M. K. Shaat
    Journal of Radioanalytical and Nuclear Chemistry, 2010, 285 : 321 - 329
  • [4] Inter-laboratory comparison of sensory profiles:: methodology and results
    Pagès, J
    Husson, F
    FOOD QUALITY AND PREFERENCE, 2001, 12 (5-7) : 297 - 309
  • [5] INTER-LABORATORY COMPARISON OF RESULTS OF ERYTHROCYTE PROTOPORPHYRIN ANALYSIS
    JACKSON, KW
    CLINICAL CHEMISTRY, 1978, 24 (12) : 2135 - 2138
  • [6] Evaluation of mouse bioassay results in an inter-laboratory comparison for paralytic shellfish poisoning toxins
    曹际娟
    郑江
    于兵
    王秋艳
    徐君怡
    李爱峰
    Journal of Oceanology and Limnology, 2011, (04) : 912 - 916
  • [7] Evaluation of mouse bioassay results in an inter-laboratory comparison for paralytic shellfish poisoning toxins
    Cao Jijuan
    Zheng Jiang
    Yu Bing
    Wang Qiuyan
    Xu Junyi
    Li Aifeng
    CHINESE JOURNAL OF OCEANOLOGY AND LIMNOLOGY, 2011, 29 (04): : 912 - 916
  • [8] Evaluation of mouse bioassay results in an inter-laboratory comparison for paralytic shellfish poisoning toxins
    Jijuan Cao
    Jiang Zheng
    Bing Yu
    Qiuyan Wang
    Junyi Xu
    Aifeng Li
    Chinese Journal of Oceanology and Limnology, 2011, 29 : 912 - 916
  • [9] Results of an inter-laboratory comparison of methods for quantitative clay analysis
    Ottner, F
    Gier, S
    Kuderna, M
    Schwaighofer, B
    APPLIED CLAY SCIENCE, 2000, 17 (5-6) : 223 - 243
  • [10] COMPARISON OF INTER-LABORATORY RESULTS FOR BLOOD LEAD WITH RESULTS FROM A DEFINITIVE METHOD
    BOONE, J
    HEARN, T
    LEWIS, S
    CLINICAL CHEMISTRY, 1979, 25 (03) : 389 - 393