Computer-assisted analysis of functional internal rotation after reverse total shoulder arthroplasty: implications for component choice and orientation

被引:5
|
作者
Hochreiter, Bettina [1 ]
Meisterhans, Michel [1 ]
Zindel, Christoph [1 ]
Calek, Anna-Katharina [1 ]
Gerber, Christian [1 ,2 ]
机构
[1] Univ Zurich, Balgrist Univ Hosp, Dept Orthoped, Forchstr 340, CH-8008 Zurich, Switzerland
[2] Orthopaed Res Ctr, Balgrist Campus, Zurich, Switzerland
关键词
Reverse total shoulder arthroplasty; RTSA; Internal rotation; Extension; Neck shaft angle; Baseplate; Orientation; Position; NECK-SHAFT ANGLE; GLENOID LATERALIZATION; PROXIMAL HUMERUS; MOTION; RANGE; DESIGN; RETROVERSION; INCLINATION; PROSTHESIS; POSITION;
D O I
10.1186/s40634-023-00580-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeFunctional internal rotation (IR) is a combination of extension and IR. It is clinically often limited after reverse total shoulder arthroplasty (RTSA) either due to loss of extension or IR in extension. It was the purpose of this study to determine the ideal in-vitro combination of glenoid and humeral components to achieve impingement-free functional IR.MethodsRTSA components were virtually implanted into a normal scapula (previously established with a statistical shape model) and into a corresponding humerus using a computer planning program (CASPA). Baseline glenoid configuration consisted of a 28 mm baseplate placed flush with the posteroinferior glenoid rim, a baseplate inclination angle of 96 degrees (relative to the supraspinatus fossa) and a 36 mm standard glenosphere. Baseline humeral configuration consisted of a 12 mm humeral stem, a metaphysis with a neck shaft angle (NSA) of 155 degrees (+ 6 mm medial offset), anatomic torsion of -20 degrees and a symmetric PE inlay (36mmx0mm). Additional configurations with different humeral torsion (-20 degrees, + 10 degrees), NSA (135 degrees, 145 degrees, 155 degrees), baseplate position, diameter, lateralization and inclination were tested. Glenohumeral extension of 5, 10, 20, and 40 degrees was performed first, followed by IR of 20, 40, and 60 degrees with the arm in extension of 40 degrees-the value previously identified as necessary for satisfactory clinical functional IR. The different component combinations were taken through simulated ROM and the impingement volume (mm(3)) was recorded. Furthermore, the occurrence of impingement was read out in 5 degrees motion increments.ResultsIn all cases where impingement occurred, it occurred between the PE inlay and the posterior glenoid rim. Only in 11 of 36 combinations full functional IR was possible without impingement. Anterosuperior baseplate positioning showed the highest impingement volume with every combination of NSA and torsion. A posteroinferiorly positioned 26 mm baseplate resulting in an additional 2 mm of inferior overhang as well as 6 mm baseplate lateralization offered the best impingement-free functional IR (5/6 combinations without impingement). Low impingement potential resulted from a combination of NSA 135 degrees and + 10 degrees torsion (4/6 combinations without impingement), followed by NSA 135 degrees and -20 degrees torsion (3/6 combinations without impingement) regardless of glenoid setup.ConclusionThe largest impingement-free functional IRs resulted from combining a posteroinferior baseplate position, a greater inferior glenosphere overhang, 90 degrees of baseplate inclination angle, 6 mm glenosphere lateralization with respect to baseline setup, a lower NSA and antetorsion of the humeral component. Surgeons can employ and combine these implant configurations to achieve and improve functional IR when planning and performing RTSA.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Computer-assisted analysis of functional internal rotation after reverse total shoulder arthroplasty: implications for component choice and orientation
    Bettina Hochreiter
    Michel Meisterhans
    Christoph Zindel
    Anna-Katharina Calek
    Christian Gerber
    Journal of Experimental Orthopaedics, 10
  • [2] Extension of the shoulder is essential for functional internal rotation after reverse total shoulder arthroplasty
    Hochreiter, Bettina
    Wyss, Sabine
    Gerber, Christian
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (06) : 1166 - 1174
  • [3] Extension of the Shoulder is Essential for Functional Internal Rotation After Reverse Total Shoulder Arthroplasty
    Hochreiter, Bettina
    Wyss, Sabine
    Gerber, Christian
    SWISS MEDICAL WEEKLY, 2021, 151 : 10S - 10S
  • [4] Factors Influencing Functional Internal Rotation after Reverse Total Shoulder Arthroplasty
    Hochreiter, Bettina
    Hasler, Anita
    Hasler, Julian
    Kriechling, Philipp
    Borbas, Paul
    Gerber, Christian
    SWISS MEDICAL WEEKLY, 2021, 151 : 10S - 10S
  • [5] Functional internal rotation after shoulder arthroplasty: a comparison of anatomic and reverse shoulder arthroplasty
    Triplet, Jacob J.
    Everding, Nathan G.
    Levy, Jonathan C.
    Moor, Molly A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (06) : 867 - 874
  • [6] Predictors of Internal Rotation after Reverse Shoulder Arthroplasty
    Gibian, Joseph T.
    Sokrab, Ruba
    Hill, Jeffrey R.
    Keener, Jay D.
    Zmistowski, Benjamin M.
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2023, 11 (11): : 696 - 703
  • [7] Computer-Assisted Surgery in Reverse Shoulder Arthroplasty: Early Experience
    Giorgini, Andrea
    Tarallo, Luigi
    Novi, Michele
    Porcellini, Giuseppe
    INDIAN JOURNAL OF ORTHOPAEDICS, 2021, 55 (04) : 1003 - 1008
  • [8] Computer-Assisted Surgery in Reverse Shoulder Arthroplasty: Early Experience
    Andrea Giorgini
    Luigi Tarallo
    Michele Novi
    Giuseppe Porcellini
    Indian Journal of Orthopaedics, 2021, 55 : 1003 - 1008
  • [9] The influence of posture and scapulothoracic orientation on the choice of humeral component retrotorsion in reverse total shoulder arthroplasty
    Moroder, Philipp
    Akguen, Doruk
    Plachel, Fabian
    Baur, Alexander D. J.
    Siegert, Paul
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (10) : 1992 - 2001
  • [10] Factors affecting internal rotation after reverse shoulder arthroplasty
    Kim, Su Cheol
    Lee, Je Eun
    Lee, Sang Min
    Yoo, Jae Chul
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2022, 27 (01) : 131 - 138