Modeling urban canopy air temperature at city-block scale based on urban 3D morphology parameters- A study in Tianjin, North China

被引:10
|
作者
Li, Xiaorui [1 ,2 ]
Yang, Bisheng [1 ,2 ]
Liang, Fuxun [1 ,2 ]
Zhang, Hongsheng [3 ]
Xu, Yong [4 ]
Dong, Zhen [1 ,5 ]
机构
[1] Wuhan Univ, State Key Lab Informat Engn Surveying Mapping & Re, Wuhan, Peoples R China
[2] Wuhan Univ, Engn Res Ctr Spatio temporal Data Smart Acquisit &, Minist Educ China, Wuhan, Peoples R China
[3] Univ Hong Kong, Dept Geog, Hong Kong, Peoples R China
[4] Guangzhou Univ, Sch Geog Sci, Dept Geog Informat Sci, Guangzhou, Peoples R China
[5] Wuhan Univ, Hubei Luojia Lab, Wuhan, Peoples R China
关键词
Urban heat island; Canopy air temperature; Local climate zone; ENVI-met; Urban 3D morphology; Random forest regression; LOCAL CLIMATE ZONES; HEAT-ISLAND; MICROCLIMATE MODEL; SURFACE;
D O I
10.1016/j.buildenv.2023.110000
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Urban 3D morphology significantly influences the outdoor thermal environment. Understanding the influence of urban expansion in both horizontal and vertical landscapes helps the canopy urban heat island (CUHI) effect mitigation. However, the microscale numerical CUHI models are difficult to be applied for large-area CUHI effect studies. On the other hand, the mesoscale CUHI models make a wider study area workable but lost some of the model accuracies. To perform a large-area study on the CUHI effect with relatively light computing costs and fine accuracy, this paper builds a canopy air temperature predicting model at city-block scale with urban 3D morphology parameters including building coverage ratio (BCR), grass coverage ratio (GCR) and the mean value of building height (BH) to obtain the citywide block-mean 2-m temperature (T2M). The model accuracy was validated through RMSEs and comparison with the mereological station data. The proposed model shows an RMSE of 0.286 straight degrees C and an R-square of 0.83. Using the validated model, Tianjin with an area of 647 km 2 was performed to investigate the effects of vertical landscape on the canopy air temperature under different scenarios between 2010 and 2016, including the changes in landcover and building heights. It finds that a 40% increase in BCR may lead to the highest canopy air temperature, and the increase of BH may lead to an increase in the canopy air temperature in low-rise and high-rise building areas, but there is an opposite trend in multi-story and mid-rise building areas.
引用
收藏
页数:11
相关论文
共 46 条
  • [1] The influences of 2D/3D urban morphology on land surface temperature at the block scale in Chinese megacities
    Zhang, Zhenchao
    Luan, Weixin
    Yang, Jun
    Guo, Andong
    Su, Min
    Tian, Chuang
    URBAN CLIMATE, 2023, 49
  • [2] 3D City modeling for urban scale heating energy demand forecasting
    Strzalka, Aneta
    Bogdahn, Juergen
    Coors, Volker
    Eicker, Ursula
    HVAC&R RESEARCH, 2011, 17 (04): : 526 - 539
  • [3] The Study on Urban Planning based on 3D City Model
    Pang, Chun Yu
    Yin, Qing
    ADVANCED BUILDING MATERIALS AND SUSTAINABLE ARCHITECTURE, PTS 1-4, 2012, 174-177 : 2490 - 2493
  • [4] How does 2D and 3D of urban morphology affect the seasonal land surface temperature in Island City? A block-scale perspective
    Zhu, Zhipeng
    Shen, Yuanping
    Fu, Weicong
    Zheng, Dulai
    Huang, Peilin
    Li, Junyi
    Lan, Yuxiang
    Chen, Ziru
    Liu, Qunyue
    Xu, Xiaoling
    Yao, Xiong
    ECOLOGICAL INDICATORS, 2023, 150
  • [5] The effect of urban 2D and 3D morphology on air temperature in residential neighborhoods
    Tian, Yunyu
    Zhou, Weiqi
    Qian, Yuguo
    Zheng, Zhong
    Yan, Jingli
    LANDSCAPE ECOLOGY, 2019, 34 (05) : 1161 - 1178
  • [6] The effect of urban 2D and 3D morphology on air temperature in residential neighborhoods
    Yunyu Tian
    Weiqi Zhou
    Yuguo Qian
    Zhong Zheng
    Jingli Yan
    Landscape Ecology, 2019, 34 : 1161 - 1178
  • [7] Study on correlation between air temperature and urban morphology parameters in built environment in northern China
    Tong S.
    Wong N.H.
    Jusuf S.K.
    Tan C.L.
    Wong H.F.
    Ignatius M.
    Tan E.
    Tong, Shanshan (bdgtong@nus.edu.sg), 2018, Elsevier Ltd (127) : 239 - 249
  • [8] Urban 2D and 3D morphology and the pattern of ozone pollution: a 68-city study in China
    Shengyang Hong
    Chengcong Wang
    Wenjie Wang
    Peng Zhang
    Yujie Guo
    Zijun Ma
    Wenhai Hong
    Zhibin Ren
    Landscape Ecology, 39
  • [9] Urban 2D and 3D morphology and the pattern of ozone pollution: a 68-city study in China
    Hong, Shengyang
    Wang, Chengcong
    Wang, Wenjie
    Zhang, Peng
    Guo, Yujie
    Ma, Zijun
    Hong, Wenhai
    Ren, Zhibin
    LANDSCAPE ECOLOGY, 2024, 39 (02)
  • [10] Multidisciplinary parameters for characterizing the 3D urban morphology: An overview based on the relational perspective
    Li, Kaixin
    Zeng, Hui
    SUSTAINABLE CITIES AND SOCIETY, 2024, 106