Diagnostic Accuracy of Cord Bilirubin to Predict the Need for Phototherapy in Healthy Neonates >35-Week Gestational Age: A Systematic Review and Meta-Analysis

被引:1
|
作者
Anne, Rajendra Prasad [1 ,4 ]
Rahiman, Emine A. [1 ]
Dudeja, Sankalp [2 ]
Kumar, Ashutosh [3 ]
机构
[1] All India Inst Med Sci, Hyderabad, Telangana, India
[2] Sita Ram Bhartia Inst Sci & Res, New Delhi, India
[3] Command Hosp, Lucknow, India
[4] All India Inst Med Sci, Hyderabad Metropolitan Reg, Bibinagar 508126, India
关键词
cord bilirubin; diagnostic accuracy; high-risk neonates; bivariate model; BLOOD BILIRUBIN; SIGNIFICANT HYPERBILIRUBINEMIA; TERM; NEWBORNS; INFANTS; LEVEL; RISK;
D O I
10.1016/j.jceh.2022.11.011
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objective: Early discharge puts neonates at risk of delayed detection of jaundice and resulting neurological injury. In these neonates, we can use cord bilirubin to make predictions. In this meta-analysis, we assessed the diagnostic accuracy of cord bilirubin in predicting the need for phototherapy (AAP-2004 or NICE-2010 charts). Methods: We searched the databases of PubMed, Embase, Cochrane Library, Google Scholar, and Index Medicus for Southeast Asian Region. We included all observational studies that assessed the diagnostic accuracy of cord bilirubin. A bivariate model was used to pool the data in prespecified range of cord bilirubin levels (<1.5 mg/dl, 1.5- 2.0 mg/dl, 2.0-2.5 mg/dl, 2.5-3.0 mg/dl, and >3.0 mg/dl). Data were pooled separately for studies including all neonates (no risk stratification), high-risk neonates (Rh and/or ABO incompatibility only), and low-risk neonates (excluded Rh and ABO incompatibility). Results: Of the 1990 unique records, we studied 153 full texts and included 54 studies in the meta-analysis. For all the three groups of studies, the highest diagnostic odds ratio was noted for a cord bilirubin cut-off of 2.5-3.0 mg/dl (all neonates: 22.5, 95% CI: 21.1, 22.9; high-risk neonates: 75.5,95% CI: 63, 85.7; low-risk neonates: 91.9; 95% CI: 64, 134.14). Using the same cut-off, the studies including all neonates without risk stratification had a pooled sensitivity of 0.31(95% CI: 0.18, 0.47) and a pooled specificity of 0.98 (0.96, 0.99) in predicting the need for phototherapy. In studies on high-risk neonates, the pooled sensitivity was 0.8 (0.39, 0.96) and pooled specificity was 0.95 (0.78, 0.99). In studies on low-risk neonates, the pooled sensitivity was 0.74 (0.39, 0.93) and pooled specificity of 0.97 (0.91, 0.99). We noted significant heterogeneity and a high risk of bias in the index test's conduct. Conclusion: A cord bilirubin cut-off of 2.5-3 mg/dl has good diagnostic accuracy in predicting the need for phototherapy in neonates. Registration number: CRD42020196216. ( J CLIN EXP HEPATOL 2023;13:666-681)
引用
收藏
页码:666 / 681
页数:16
相关论文
共 50 条
  • [1] Diagnostic accuracy of glycated hemoglobin for gestational diabetes mellitus: a systematic review and meta-analysis
    Renz, Paula B.
    Chume, Fernando C.
    Timm, Joao R. T.
    Pimentel, Ana L.
    Camargo, Joiza L.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2019, 57 (10) : 1435 - 1449
  • [2] Accuracy of prenatal and postnatal biomarkers for estimating gestational age: a systematic review and meta-analysis
    Bradburn, Elizabeth
    Conde-Agudelo, Agustin
    Roberts, Nia W.
    Villar, Jose
    Papageorghiou, Aris T.
    ECLINICALMEDICINE, 2024, 70
  • [3] The impact of lateral placenta on preeclampsia and small for gestational age neonates: a systematic review and meta-analysis
    Siargkas, Antonios
    Tsakiridis, Ioannis
    Grammenos, Petros
    Apostolopoulou, Aikaterini
    Giouleka, Sonia
    Mamopoulos, Apostolos
    Athanasiadis, Apostolos
    Dagklis, Themistoklis
    JOURNAL OF PERINATAL MEDICINE, 2023, 51 (04) : 468 - 476
  • [4] Metabolic profile of children and neonates born small for gestational age: a systematic review and meta-analysis
    Chatzakis, C.
    Kissoudi, K.
    Demertzidou, E.
    Dinas, K.
    Sarafidis, K.
    Mastorakos, G.
    Sotiriadis, A.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, 62 : 11 - 11
  • [5] Diagnostic accuracy of lung ultrasound to predict weaning outcome: a systematic review and meta-analysis
    Zhang, Zhiyang
    Guo, Li
    Wang, Huawei
    Zhang, Ze
    Shen, Limin
    Zhao, Heling
    FRONTIERS IN MEDICINE, 2024, 11
  • [6] Diagnostic accuracy of diaphragm ultrasound to predict weaning outcome: A systematic review and meta-analysis
    Le Neindre, Aymeric
    Philippart, Francois
    Luperto, Marta
    Wormser, Johan
    Morel-Sapene, Johanna
    Aho, Serge L.
    Mongodi, Silvia
    Mojoli, Francesco
    Bouhemad, Belaid
    INTERNATIONAL JOURNAL OF NURSING STUDIES, 2021, 117
  • [7] Phototherapy Effects on Zinc Level of Neonates With Hyperbilirubinemia: A Systematic Review and Meta-analysis
    Sarokhani, Diana
    Adibi, Amir
    Abdan, Mohsen
    Fakhri, Moloud
    JOURNAL OF PEDIATRICS REVIEW, 2023, 11 (02) : 107 - 116
  • [8] Combined Anticoagulant Therapy for Prevention of Preeclampsia and Small for Gestational Age Neonates: A Systematic Review and Meta-analysis
    Kontovazainitis, Christos-Georgios
    Gialamprinou, Dimitra
    Katsaras, Georgios N.
    Pouliakis, Abraham
    Theodoridis, Theodoros
    Mitsiakos, Georgios
    AMERICAN JOURNAL OF PERINATOLOGY, 2023, 40 (16) : 1745 - 1764
  • [9] Association between maternal rheumatoid arthritis and small for gestational age neonates: a systematic review and meta-analysis
    Tian, Lv
    Zhang, Zhiyuan
    Mao, Yuting
    Zong, Minru
    FRONTIERS IN PUBLIC HEALTH, 2023, 11
  • [10] Diagnostic test accuracy: methods for systematic review and meta-analysis
    Campbell, Jared M.
    Klugar, Miloslav
    Ding, Sandrine
    Carmody, Dennis P.
    Hakonsen, Sasja J.
    Jadotte, Yuri T.
    White, Sarahlouise
    Munn, Zachary
    INTERNATIONAL JOURNAL OF EVIDENCE-BASED HEALTHCARE, 2015, 13 (03) : 154 - 162