Accuracy of the PEARL-DGS Formula for Intraocular Lens Power Calculation in Post-Myopic Laser Refractive Corneal Surgery Eyes

被引:0
|
作者
Oh, Richul [1 ,2 ]
Hyon, Joon young
Jeon, Hyun sun [3 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Ophthalmol, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Ophthalmol, Seoul, South Korea
[3] Seoul Natl Univ, Coll Med, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
IN-SITU KERATOMILEUSIS; PREDICTION; CATARACT;
D O I
10.1016/j.ajo.2023.10.020
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the accuracy of the PEARL-DGS formula for intraocular lens (IOL) power calculation in post-myopic laser refractive corneal surgery eyes.DESIGN: Retrospective case series.METHODS: A total of 139 eyes of 139 patients (mean axial length: 27.4 +/- 2.1 mm) who had prior myopic laser refractive corneal surgery and subsequent cataract surgery using Tecnis ZCB00 from March 2018 to February 2023 were included. Refractive outcomes of 5 formulas (Barrett True K, Haigis-L, Hoffer-QST, PEARL-DGS, and Shammas-PL) were evaluated. Prediction error was defined as the difference between the measured and predicted postoperative refractive spherical equivalent using the IOL power actually implanted. Mean prediction error (MPE), median absolute prediction error (MedAE), and mean absolute prediction error were calculated.RESULTS: Without constant optimization, the PEARL-DGS resulted in a MPE of +0.05 +/- 0.65 diopters (D), whereas the other formulas resulted in myopic shifts. The MedAEs of the formulas were 0.39, 0.53, 0.65, 0.85, and 1.11 D for the PEARL-DGS, Hoffer-QST, Barrett True K, Shammas-PL, and Haigis-L, respectively, in order of magnitude (P < .05). With constant optimization, there were no statistically significant differences in the MedAEs among the 5 formulas (P = .388).CONCLUSIONS: In comparison to other IOL formulas, the PEARL-DGS resulted in better refractive outcomes after cataract surgery in post-myopic laser refractive corneal surgery eyes without constant optimization. We suggest that PEARL-DGS be considered as the first choice for IOL power calculation in these eyes when the clinicians do not have their optimized constants.
引用
收藏
页码:79 / 87
页数:9
相关论文
共 50 条
  • [1] Intraocular lens power calculation using adjusted corneal power in eyes after myopic corneal refractive surgery
    Tan, Qian
    Lin, Ding
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [2] Metaanalysis of intraocular lens power calculation after laser refractive surgery in myopic eyes
    Chen, Xu
    Yuan, Fei
    Wu, Lianqun
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01): : 163 - 170
  • [3] The Development of a Thick-Lens Post-Myopic Laser Vision Correction Intraocular Lens Calculation Formula
    Debellemaniere, Guillaume
    Mechleb, Nicole
    Bernier, Timothte
    Ancel, Jean-marc
    Gauvin, Mathieu
    Wallerstein, Avi
    Saad, Alain
    Gatinel, Damien
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 262 : 40 - 47
  • [4] Accuracy of intraocular lens power calculation formulae after laser refractive surgery in myopic eyes: a meta-analysis
    Hongyu Li
    Li Nan
    Jun Li
    Hui Song
    [J]. Eye and Vision, 7
  • [5] Accuracy of intraocular lens power calculation formulae after laser refractive surgery in myopic eyes: a meta-analysis
    Li, Hongyu
    Nan, Li
    Li, Jun
    Song, Hui
    [J]. EYE AND VISION, 2020, 7 (01)
  • [6] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Savini, Giacomo
    Hoffer, Kenneth J.
    [J]. EYE AND VISION, 2018, 5
  • [7] Intraocular lens power calculation in eyes after corneal refractive surgery
    Seitz, B
    Langenbucher, A
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2000, 16 (03) : 349 - 361
  • [8] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Anders, Philipp
    Anders, Lisa-Marie
    Barbara, Adel
    Szentmary, Nora
    Langenbucher, Achim
    Gatzioufas, Zisis
    [J]. THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2022, 14
  • [9] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Giacomo Savini
    Kenneth J. Hoffer
    [J]. Eye and Vision, 5
  • [10] Comparison of the accuracy of intraocular lens power calculation formulas for eyes after corneal refractive surgery
    Wang, Xiao-Zhen
    Cui, Rui
    Song, Xu-Dong
    Yun, Bo
    Qian, Jin
    Ding, Ning
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (14)