An Engineering Method for Resonant Microcantilever Using Double-Channel Excitation and Signal Acquisition Based on LabVIEW

被引:0
|
作者
Wang, Shanlai [1 ]
Cao, Zhi [2 ,3 ]
Zhang, Xiaoyang [1 ]
Yu, Haitao [2 ]
Yao, Lei [1 ]
机构
[1] Shanghai Univ, Sch Microelect, Shanghai 200444, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Lab Transducer Technol, Shanghai 200050, Peoples R China
[3] Shanghai Inst Technol, Sch Chem & Environm Engn, Shanghai 201418, Peoples R China
关键词
resonant microcantilever; TGA; dual-channel; LabVIEW; RAMAN-SPECTROSCOPY; FUEL;
D O I
10.3390/mi14040823
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Resonant microcantilevers have the advantages of ultra-high heating rates, analysis speed, ultra-low power consumption, temperature programming, and trace sample analysis when applied in TGA. However, the current single-channel testing system for resonant microcantilevers can only detect one sample at a time, and need two program heating tests to obtain the thermogravimetric curve of a sample. In many cases, it is desirable to obtain the thermogravimetric curve of a sample with a single-program heating test and to simultaneously detect multiple microcantilevers for testing multiple samples. To address this issue, this paper proposes a dual-channel testing method, where a microcantilever is used as a control group and another microcantilever is used as an experimental group, to obtain the thermal weight curve of the sample in a single program temperature ramp test. With the help of the LabVIEW's convenient parallel running method, the functionality of simultaneously detecting two microcantilevers is achieved. Experimental validation showed that this dual-channel testing system can obtain the thermogravimetric curve of a sample with a single program heating test and detect two types of samples simultaneously.
引用
收藏
页数:16
相关论文
共 34 条
  • [1] High-Precision Small-Signal Model for Double-Channel–High-Electron-Mobility Transistors Based on the Double-Channel Coupling Effect
    Zhao, Ziyue
    Yu, Qian
    Lu, Yang
    Yi, Chupeng
    Liu, Xin
    Feng, Ting
    Zhao, Wei
    Chen, Yilin
    Yang, Ling
    Ma, Xiaohua
    Hao, Yue
    Micromachines, 2025, 16 (02)
  • [2] Acquisition of FDM Signal by Using Sound card Based on LabVIEW
    Yin Xiao-qi
    MECHANICAL AND ELECTRONICS ENGINEERING III, PTS 1-5, 2012, 130-134 : 2023 - 2026
  • [3] Design of multi-channel signal acquisition system of the torsion spring based on LabVIEW
    Ding Jianjun
    Sun Chao
    CEIS 2011, 2011, 15
  • [4] A smartphone-based double-channel fluorescence setup for immunoassay of a carcinoembryonic antigen using CuS nanoparticles for signal amplification
    Wang, Honghai
    Sun, Yan
    Yue, Weiwei
    Kang, Qi
    Li, Huijuan
    Shen, Dazhong
    ANALYST, 2018, 143 (07) : 1670 - 1678
  • [5] Double-channel colonoscopic snare resection of large pedunculated polyps using a clipping method
    Tsai, M. H.
    Wang, K.
    Chou, S. J.
    Chen, V.
    Yang, Y. C.
    ENDOSCOPY, 2007, 39 : E200 - E200
  • [6] Forward squint SAR double-channel clutter suppression method based on hypersonic platform
    Qi C.
    Cao Y.
    Wang Y.
    Wu C.
    Xi Tong Gong Cheng Yu Dian Zi Ji Shu/Systems Engineering and Electronics, 2019, 41 (01): : 58 - 65
  • [7] Measurement Method for Nonlinearity in Heterodyne Laser Interferometers Based on Double-Channel Quadrature Demodulation
    Fu, Haijin
    Ji, Ruidong
    Hu, Pengcheng
    Wang, Yue
    Wu, Guolong
    Tan, Jiubin
    SENSORS, 2018, 18 (09)
  • [8] Research on mining method of submarine natural gas hydrates based on a double-channel lift pump
    Zeng, Yicong
    Xu, Hailiang
    Wu, Wanrong
    Wu, Bo
    ADVANCED MATERIALS DESIGN AND MECHANICS, 2012, 569 : 509 - 516
  • [9] Resonant characteristics of microcantilever by using self-mixing interferometer based on phase reconstruction method
    Wang, Shaoqing
    Wang, Xiangzhao
    CHINESE OPTICS LETTERS, 2010, 8 (02) : 177 - 180
  • [10] Resonant characteristics of microcantilever by using self-mixing interferometer based on phase reconstruction method
    王少卿
    王向朝
    Chinese Optics Letters, 2010, 8 (02) : 177 - 180