Due to the use of welded finned tubes in heat exchangers, gas blocks are characterized by very good electric energy production performance, and their reliability can reach 98%. Finned tubes used in heat exchangers are usually welded. Such tubes should be characterised by the following properties: high thermal performance, good resistance to high-temperature corrosion in a flue gas atmosphere, and appropriate joint strength and hardness. The most popular technology for welding finned tubes is MAG. MAG-welded joints are characterised by considerable spattering, weld discontinuities (up to 60%), and non-axial fin alignment. Such irregularities result in a considerably reduced heat flux due to the heat transfer resistance occurring in the welded joint. It has been shown that with weld discontinuities of 20%, the thermal performance of welded finned tubes reduces considerably. This paper proposes the possibility of welding finned tubes with a laser. The thermal properties of laser-welded finned tubes were compared with those of MAG-welded tubes. It was found that the thermal performance of welded finned tubes was three times higher than that of plain tubes. However, the thermal performance was not found to be affected by the welding technology. The correct heat flow at the level of 95% occurs in the tube/fin joint even with joint penetration of 0.01 mm, however, the absence of metallic continuity in a joint results in a drastically reduced thermal performance (by 50%) and the overheating of fins, which affects their durability.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] INVESTIGATION OF THERMAL PERFORMANCE OF PERFORATED FINNED HEAT EXCHANGERS
    Yakar, G.
    Karabacak, R.
    EXPERIMENTAL HEAT TRANSFER, 2015, 28 (04) : 354 - 365
  • [2] Constructal design of finned tubes used in air-cooled heat exchangers
    Hossein Shokouhmand
    Shoeib Mahjoub
    Mohammad Reza Salimpour
    Journal of Mechanical Science and Technology, 2014, 28 : 2385 - 2391
  • [3] Constructal design of finned tubes used in air-cooled heat exchangers
    Shokouhmand, Hossein
    Mahjoub, Shoeib
    Salimpour, Mohammad Reza
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2014, 28 (06) : 2385 - 2391
  • [4] HOW EFFECTIVE ARE FINNED TUBES IN HEAT EXCHANGERS? .
    Murty, K.N.
    Chemical Engineering (New York), 1986, 93 (07):
  • [5] Internal Finned Heat Exchangers: Thermal and Hydraulic Performance Review
    Pulagam, Madhu Kalyan Reddy
    Rout, Sachindra Kumar
    Muduli, Kamal Kanta
    Syed, Shoeb Ahmed
    Barik, Debabrata
    Hussein, Ahmed Kadhim
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2024, 42 (02) : 583 - 592
  • [6] Welding of tubes to plates in heat exchangers
    Manzoli, T.
    Sovardi, L.
    Rivista Italiana della Saldatura, 1993, 45 (04): : 341 - 344
  • [7] HOW EFFECTIVE ARE FINNED TUBES IN HEAT-EXCHANGERS
    MURTY, KN
    CHEMICAL ENGINEERING, 1986, 93 (07) : 120 - &
  • [8] CHARACTERIZATION OF FINNED TUBES HEAT-EXCHANGERS BY MEANS OF CANUT SOFTWARE - APPLICATION TO PERFORMANCE SIMULATION
    ARMAND, JL
    MOLLE, N
    REVUE GENERALE DE THERMIQUE, 1991, 30 (353): : 312 - 319
  • [9] HEAT EXCHANGE RESEARCH OF THE BOTH SIDE FINNED TUBES APPLIED TO THE HEAT EXCHANGERS
    Telejko, Tadeusz
    Szajding, Artur
    RYNEK ENERGII, 2011, (05): : 104 - 110
  • [10] Heat exchange during boiling of fluids on finned walls of tubes in heat exchangers
    Gogonin I.I.
    Chemical and Petroleum Engineering, 2009, 45 (5-6) : 329 - 335