Performance enhancements and NOx emission reductions using novel exhaust-driven hybrid gas turbine inlet air-cooling techniques

被引:0
|
作者
Bassily, Ashraf M. [1 ,2 ]
机构
[1] Alexandria Higher Inst Engn & Technol, Dept Mechatron, Alexandria, Egypt
[2] 31 Ahmed El Barrad St, Cairo 11241, Egypt
关键词
Combined cycle; ejector cooling; hybrid cooling; improving power; inlet cooling; NOx emissions; performance enhancement; CYCLE POWER-PLANT; THERMOECONOMIC ANALYSIS; COST OPTIMIZATION; EJECTOR; SYSTEM; STEAM; IRREVERSIBILITY; IMPROVEMENT; IMPACT;
D O I
10.1177/09544089231210782
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
For combined cycles, gas turbine inlet air-cooling (GTIAC) increases the mass flow rates of both air and the generated steam of the heat recovery steam generator and hence power output. The introduction of exhaust gas recirculation (EGR) to reduce NOx emissions necessitates the application of GTIAC to overcome the adverse effects of gas turbine (GT) inlet air heating that accompany EGR. For a hot-humid climate, the r5egular cooling methods consume a significant amount of energy while desiccant and inlet-fogging are not effective. The main purpose of this study is to introduce innovative exhaust-driven hybrid GTIAC techniques that can reduce effectively the inlet temperature of the combined cycle in a hot-humid climate without consuming a substantial amount of energy and examine the effects of applying such techniques on the performance and NOx emissions. In this paper, a thorough analysis for the effect of increasing ambient temperature (T-o) and relative humidity (RHo) on the performance and NOx emissions of the air-cooled GT combined cycle (ACGTCC) is presented and the novel exhaust-driven hybrid (NE-DH) GTIAC systems of desiccant-ejector, ejector-refrigeration, and desiccant-ejector-refrigeration are applied to ACGTCC and optimized for maximum power output. The 1-D model at the double choking was used to model the performance of the ejector GTIAC technique. The results indicate that applying NE-DH GTIAC techniques results in gains in power, which vary between 0.31% and 0.6% per degrees C rise in T-o and an efficiency improvement of up to about 0.5 percentage point and significant reductions in both capital and maintenance costs compared with applying the refrigeration GTIAC system. The introduction of ejector and desiccant cooling decreases NOx emissions further and adds no additional equipment cost if implemented together with EGR or some CO2 capture techniques. A suggested plan for GTIAC that reduces NOx emissions by up to 25% is presented.
引用
收藏
页数:19
相关论文
共 21 条
  • [1] GAS TURBINE INLET AIR COOLING USING VAPOR-ADSORPTION REFRIGERATION DRIVEN BY POWER PLANT EXHAUST
    Panyam, Varuneswara Reddy
    Dandotiya, Devendra
    Banker, Nitin
    PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE, 2017, VOL 1, 2018,
  • [2] THERMODYNAMIC ANALYSIS OF GAS TURBINE PERFORMANCE WITH DIFFERENT INLET AIR COOLING TECHNIQUES
    Pereira dos Santos, Ana Paula
    de Andrade, Claudia Regina
    PROCEEDINGS OF THE ASME TURBO EXPO 2012, VOL 3, 2012, : 79 - 89
  • [3] Analysis of Gas Turbine Performance with Inlet Air Cooling Techniques Applied to Brazilian Sites
    Santos, Ana Paula
    Andrade, Claudia R.
    JOURNAL OF AEROSPACE TECHNOLOGY AND MANAGEMENT, 2012, 4 (03) : 341 - 353
  • [4] Performance improvement of gas turbine power plants by utilizing turbine inlet air-cooling (TIAC) technologies in Riyadh, Saudi Arabia
    Baakeem, Saleh S.
    Orfi, Jamel
    Al-Ansary, Hany
    APPLIED THERMAL ENGINEERING, 2018, 138 : 417 - 432
  • [5] Performance and sensitivity analysis of a combined cycle gas turbine power plant by various inlet air-cooling systems
    Rahim, Murad A.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2012, 226 (A7) : 922 - 931
  • [6] Thermodynamic assessment of impact of inlet air cooling techniques on gas turbine and combined cycle performance
    Mohapatra, Alok Ku
    Sanjay
    ENERGY, 2014, 68 : 191 - 203
  • [7] Performance Analysis of Gas Turbine Inlet Air Cooling Plant with Hybrid Indirect Evaporative Cooling and Absorption Chiller System
    Hamedani, Amir Moradi
    Salehi, Gholamreza
    Masoomi, Mina
    Manesh, Mohammad Hasan Khoshgoftar
    INTERNATIONAL JOURNAL OF THERMODYNAMICS, 2021, 24 (03) : 248 - 259
  • [8] Using novel integrated Maisotsenko cooler and absorption chiller for cooling of gas turbine inlet air
    Dizaji, Hamed Sadighi
    Hu, Eric Jing
    Chen, Lei
    Pourhedayat, Samira
    ENERGY CONVERSION AND MANAGEMENT, 2019, 195 : 1067 - 1078
  • [9] Augmentation of gas turbine performance using integrated EAHE and Fogging Inlet Air Cooling System
    Barakat, S.
    Ramzy, Ahmed
    Hamed, A. M.
    El-Emam, S. H.
    ENERGY, 2019, 189
  • [10] GAS TURBINE PERFORMANCE ENHANCEMENT BY INLET AIR COOLING AND COOLANT PRE-COOLING USING AN ABSORPTION CHILLER
    Kwon, Hyun Min
    Kim, Jeong Ho
    Kim, Tong Seop
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2016, VOL 3, 2016,