Collaborative optimization on cooling channel flow resistance and winding temperature for integrated cooling of motor and controller

被引:0
|
作者
Tan, Libin [1 ]
Yuan, Yuejin [1 ]
Tang, Lin [2 ]
机构
[1] Shaanxi Univ Sci & Technol, Coll Mech & Elect Engn, 6 Xuefuzhong Rd, Xian 710021, Peoples R China
[2] Chongqing Univ Technol, Key Lab Adv Manufacture Technol Automobile Parts, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
Integrated cooling channel; motor; controller; Multi Island Genetic Algorithm (MIGA); collaborative optimization method; flow resistance; winding temperature; MULTIOBJECTIVE OPTIMIZATION; LARGE-CAPACITY; HEAT-TRANSFER; DESIGN; SYSTEM; LOSSES; MODEL;
D O I
10.1177/09544062231224968
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The efficiency and working performance of the motor and controller system in micro-electric vehicles depends mainly on its thermal performance, which is contingent upon effective and active cooling. The working temperature of the motor and controller may be too high during operation, which properly causes motor power reduction or motor breakdowns. Therefore, it is crucial to design a good cooling channel for better cooling the integrated motor and controller system. This work proposes an integrated cooling channel of motor and controller, and the fluid-solid coupling analysis is applied for analyzing the velocity, pressure distributions of the cooling channel, and temperature distributions of motor solid components. Meanwhile, the collaborative optimization method based on the multi-island genetic algorithm (MIGA) is used to attain optimal design parameters of the integrated cooling channel of the motor and controller for obtaining a better cooling channel design with lower flow resistance and lower winding temperatures. Results show that the original cooling channel's flow resistance and maximum winding temperature are 31.87 kPa and 120.04 degrees C, respectively. The flow resistance and winding temperature are pretty significant. After optimization, the local vortex flow and zero velocity area in optimal cooling channel design are improved, the coolant flow velocity becomes more uniform, and the flow resistance is significantly reduced. The flow resistance and maximum winding temperature of the optimal cooling channel design are 12.5 kPa and 116.76 degrees C, respectively, which are decreased compared with the original cooling channel structure, with a decrease of 39.4% and 2.7%, respectively. The research findings in this work can provide theoretical reference for solid components temperature evaluation of motor and give valuable data to cooling performance evaluation and optimization of integrated cooling channel for motor and controller system.
引用
收藏
页码:5959 / 5975
页数:17
相关论文
共 50 条
  • [1] Optimization Study of Cooling Channel for the Oil Cooling Air Gap Armature in a High-Temperature Superconducting Motor
    Yu, Shuai
    Zhou, Yong
    Wang, Yongmao
    Zhang, Ji
    Dong, Qi
    Tian, Jie
    Chen, Jing
    Leng, Feng
    ELECTRONICS, 2024, 13 (01)
  • [2] Optimization Design of Cooling Channel
    Fan, Xiying
    Guo, Yonghuan
    Min, Yong
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ELECTRONIC & MECHANICAL ENGINEERING AND INFORMATION TECHNOLOGY (EMEIT-2012), 2012, 23
  • [3] Experimental Research on the Oil Cooling of the End Winding of the Motor
    Li Ye
    Fan Tao
    Sun Wei
    Li Qi
    Wen Xuhui
    2016 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2016,
  • [4] Design of Reentrant Cooling Channel in Permanent Magnet Synchronous Motor Considering Temperature Field and Flow Field
    Wu B.
    Wan Z.
    Zhang K.
    Xi R.
    He M.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2019, 34 (11): : 2306 - 2314
  • [5] Integrated motor cooling and desiccant cooling for bus air conditioning system
    Chen, Peilin
    Zhang, Xu
    Nuantong Kongtiao/HV & AC, 2002, 32 (04):
  • [6] Cooling channel optimization for injection molding
    Pirc, N.
    Bugarin, F.
    Schmidt, F. M.
    Mongeau, M.
    NUMIFORM '07: MATERIALS PROCESSING AND DESIGN: MODELING, SIMULATION AND APPLICATIONS, PTS I AND II, 2007, 908 : 525 - +
  • [7] Investigation of the temperature conditions of a channel with cooling by a nonequilibrium vapour/droplet flow
    Komendantov, A.S.
    Kuzma-Kichta, Yu.A.
    Burdunin, M.N.
    Grebennikov, V.N.
    Savkin, N.N.
    Thermal Engineering (English translation of Teploenergetika), 1988, 35 (05): : 277 - 279
  • [8] INVESTIGATION OF THE TEMPERATURE CONDITIONS OF A CHANNEL WITH COOLING BY A NONEQUILIBRIUM VAPOR DROPLET FLOW
    KOMENDANTOV, AS
    KUZMAKICHTA, YA
    BURDUNIN, MN
    GREBENNIKOV, VN
    SAVKIN, NN
    THERMAL ENGINEERING, 1988, 35 (05) : 277 - 279
  • [9] Flow Resistance Modeling for Coolant Distribution within Canned Motor Cooling Loops
    Shengde Wang
    Zhenqiang Yao
    Hong Shen
    Chinese Journal of Mechanical Engineering, 2020, (01) : 210 - 220
  • [10] Flow Resistance Modeling for Coolant Distribution within Canned Motor Cooling Loops
    Shengde Wang
    Zhenqiang Yao
    Hong Shen
    Chinese Journal of Mechanical Engineering, 2020, 33 (01) : 210 - 220