The impact of inter-laboratory glucose bias on the diagnosis of gestational diabetes mellitus: Comparison of common automated central laboratory methods

被引:4
|
作者
Scheuer, Cathrine Munk [1 ]
Tvarno, Casper Duevang [2 ]
Gils, Charlotte [3 ]
Ravn, Julie Dahl [3 ]
McIntyre, H. David [4 ]
Jensen, Dorte Moller [5 ,6 ,7 ]
Damm, Peter [8 ,9 ]
Lauenborg, Jeannet Kepp Bruun [2 ,10 ]
Clausen, Tine Dalsgaard [1 ,8 ]
Overgaard, Martin [3 ,7 ]
机构
[1] Univ Copenhagen, Nordsjaellands Hosp, Dept Gynaecol & Obstet, Dyrehavevej 29, DK-3400 Hillerod, Denmark
[2] Nykobing Falster Sygehus, Dept Gynaecol Obstet & Paediat, Fjordvej 15, DK-4800 Nykobing, Denmark
[3] Odense Univ Hosp, Dept Clin Biochem, JB Winslows Vej 4, DK-5000 Odense, Denmark
[4] Univ Queensland, Fac Med, Mater Res, Raymond Terrace,Level 3 Aubigny Pl, South Brisbane, Qld 4101, Australia
[5] Odense Univ Hosp, Steno Diabet Ctr Odense, Klovervaenget 10, DK-5000 Odense C, Denmark
[6] Odense Univ Hosp, Dept Gynecol & Obstet, JB Winslows Vej 4, DK-5000 Odense, Denmark
[7] Univ Southern Denmark, Dept Clin Res, JB Winslows Vej 19-3, DK-5000 Odense, Denmark
[8] Rigshosp, Ctr Pregnant Women Diabet, Dept Obstet, Blegdamsvej 9, DK-2100 Copenhagen East, Denmark
[9] Univ Copenhagen, Dept Clin Med, Blegdamsvej 3b 33 5, DK-2200 Copenhagen, Denmark
[10] Copenhagen Univ Hosp Herlev, Dept Gynaecol & Obstet, Borgmester Ib Juuls Vej 11, DK-2730 Herlev, Denmark
关键词
Bias; Gestational diabetes mellitus; Glucose; Inter-laboratory; OGTT; Venous sampling; BLOOD-GLUCOSE;
D O I
10.1016/j.cca.2023.117414
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background and aims: The diagnosis of gestational diabetes mellitus (GDM) is based exclusively on glucose measurements, which are highly influenced by pre-analytical and analytical factors. Therefore, poor agreement across laboratories may affect the prevalence of GDM. We aimed to determine the inter-laboratory bias of glucose measurements and the impact on GDM prevalence.Material and methods: A prospective cohort study of women (n = 110) referred for second-trimester GDM diagnostics using a 75 g oral glucose tolerance test. Maternal glucose was assessed from venous plasma at fasting, 1 h and 2 h. Venous blood were collected in Fluoride Citrate tubes and frozen. Samples were analyzed at five central laboratories using four different automated glucose Hexokinase methods and GDM prevalence was evaluated according to WHO2013 diagnostic criteria.Results: Maximum inter-laboratory bias was 0.19, 0.30 and 0.27 mmol/L in fasting, 1 h and 2 h samples, respectively. GDM prevalence ranged 30.0-41.1% across laboratories. Conclusion: Inter-laboratory bias for mean venous glucose was low and within desirable limits. Nonetheless, the impact on GDM prevalence was considerable, which may inappropriately affect clinical practice.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Laboratory diagnosis of gestational diabetes mellitus
    Daly, N.
    Turner, M. J.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2016, 123 (09) : 1430 - 1433
  • [2] Inter-laboratory comparison of serum Lamotrigine methods
    Ritchie, J. C.
    Berry, D.
    Dugaw, K.
    McMillin, G.
    Wilson, J.
    CLINICAL CHEMISTRY, 2006, 52 (06) : A69 - A69
  • [3] INTER-LABORATORY COMPARISON OF DIAGNOSIS OF ROTAVIRUS INFECTIONS IN SCOTLAND
    MARTIN, AL
    MOLYNEAUX, PJ
    FOLLETT, EAC
    INGLIS, JM
    CLEMENTS, GB
    SERODIAGNOSIS AND IMMUNOTHERAPY IN INFECTIOUS DISEASE, 1989, 3 (02) : 135 - 140
  • [4] Inter-laboratory comparison of methods to measure androstenone in pork fat
    Kragten, S. Ampuero
    Verkuylen, B.
    Dahlmans, H.
    Hortos, M.
    Garcia-Regueiro, J. A.
    Dahl, E.
    Andresen, O.
    Feitsma, H.
    Mathur, P. K.
    Harlizius, B.
    ANIMAL, 2011, 5 (10) : 1634 - 1642
  • [5] Results of an inter-laboratory comparison of methods for quantitative clay analysis
    Ottner, F
    Gier, S
    Kuderna, M
    Schwaighofer, B
    APPLIED CLAY SCIENCE, 2000, 17 (5-6) : 223 - 243
  • [6] Inter-laboratory ring trials to evaluate serological methods for dourine diagnosis
    Cauchard, Julien
    Soldan, Andrew
    Madeline, Anthony
    Johnson, Paula
    Buscher, Philippe
    Petry, Sandrine
    VETERINARY PARASITOLOGY, 2014, 205 (1-2) : 70 - 76
  • [7] Evaluation of methods for analysis of lead in air particulates: an intra-laboratory and inter-laboratory comparison
    Harrington, James M.
    Nelson, Clay M.
    Weber, Frank X.
    Bradham, Karen D.
    Levine, Keith E.
    Rice, Joann
    ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2014, 16 (02) : 256 - 261
  • [8] Wheat varietal identification by capillary electrophoresis: An inter-laboratory comparison of methods
    Bietz, JA
    Lookhart, GL
    FOOD SCIENCE AND TECHNOLOGY-LEBENSMITTEL-WISSENSCHAFT & TECHNOLOGIE, 1997, 30 (02): : 210 - 213
  • [9] INTER-LABORATORY COMPARISON OF HLA ANTIBODY DETECTION BY SOLID PHASE METHODS
    Crowe, Deborah O.
    Fossey, Sallyanne C.
    HUMAN IMMUNOLOGY, 2009, 70 : S15 - S15
  • [10] Impact of Implementing Preanalytical Laboratory Standards on the Diagnosis of Gestational Diabetes Mellitus: A Prospective Observational Study
    Daly, Niamh
    Flynn, Iseult
    Carroll, Ciara
    Farren, Maria
    McKeating, Aoife
    Turner, Michael J.
    CLINICAL CHEMISTRY, 2016, 62 (02) : 387 - 391