Calibration transfer for near-infrared (NIR) spectroscopy based on local preserving projection

被引:1
|
作者
Bin, Jun [1 ,2 ]
Yan, Xiufang [1 ]
Liu, Renxiang [1 ,2 ]
Kang, Chao [3 ]
Chen, Yi [4 ]
机构
[1] Guizhou Univ, Coll Tobacco Sci, Guiyang 550025, Peoples R China
[2] Guizhou Key Lab Tobacco Qual Res, Guiyang 550025, Peoples R China
[3] Guizhou Univ, Sch Chem & Chem Engn, Guiyang 550025, Peoples R China
[4] Yunnan Acad Tobacco Agr Sci, Kunming 650021, Peoples R China
基金
芬兰科学院;
关键词
NIR spectroscopy; Calibration transfer; Local preserving projection (LPP); Manifold learning; Linear feature extraction; MODEL TRANSFER; STANDARDIZATION; REGRESSION; SPECTRA; COMPONENTS;
D O I
10.1016/j.vibspec.2023.103538
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Calibration transfer is a mathematical or statistical technique to solve the universality of near-infrared (NIR) spectroscopy, which is particularly important in practical applications. Therefore, a calibration transfer method based on local preserving projection (CTLPP) to correct spectral differences was proposed in this paper. Local preserving projection (LPP) is a linear feature extraction algorithm, which is a linear approximation of Laplacian Eigenmap manifold learning. It can not only overcome the shortcomings of linear feature extraction algorithms which are difficult to maintain the nonlinear manifold of the original data, but also solve the problem that nonlinear manifold learning methods are difficult to directly map new samples, which is conducive to building the conversion relationship between the source spectra and the target spectra. The transfer performance of the proposed method was evaluated in three datasets, and compared with five approaches, namely, piecewise direct standardization (PDS), calibration transfer based on independent component analysis (CTICA), spectral space transformation (SST), principal components canonical correlation analysis (PC-CCA) and calibration transfer based on neighborhood preserving embedding (CTNPE). Experimental results indicated that this proposed method can successfully correct the detection spectra among different apparatus. In addition, it can obtain relatively low prediction root mean square error (RMSEP). Therefore, the comprehensive research conducted in this work demonstrated that the proposed method is a promising calibration transfer method in NIR applications, which can provide a reference when sharing the NIR spectral models with more and more instruments.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Calibration Transfer for Near-Infrared (NIR) Spectroscopy Based on Neighborhood Preserving Embedding
    Chen, Lijuan
    Liu, Dawei
    Zhou, Jiheng
    Bin, Jun
    Li, Zhen
    [J]. ANALYTICAL LETTERS, 2021, 54 (06) : 947 - 965
  • [2] Research on Feature Extraction of Near-Infrared Spectroscopy Based on Joint Matrix Local Preserving Projection
    Hu Shan-ke
    Qin Yu-hua
    Duan Ru-min
    Wu Li-jun
    Gong Hui-li
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (12) : 3772 - 3777
  • [3] TRANSFER OF CALIBRATION FUNCTION IN NEAR-INFRARED SPECTROSCOPY
    FORINA, M
    DRAVA, G
    ARMANINO, C
    BOGGIA, R
    LANTERI, S
    LEARDI, R
    CORTI, P
    CONTI, P
    GIANGIACOMO, R
    GALLIENA, C
    BIGONI, R
    QUARTARI, I
    SERRA, C
    FERRI, D
    LEONI, O
    LAZZERI, L
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1995, 27 (02) : 189 - 203
  • [4] Rapid Determination of Phosphogypsum in Soil Based by Infrared (IR) and Near-Infrared (NIR) Spectroscopy with Multivariate Calibration
    Zhou, Bo
    Liang, Yan-Mei
    Bin, Jun
    Ding, Meng-Jiao
    Yang, Min
    Kang, Chao
    [J]. ANALYTICAL LETTERS, 2023, 56 (12) : 1962 - 1976
  • [5] Application of DS algorithm to the calibration transfer in near-infrared spectroscopy
    Li Qing-bo
    Zhang Guang-jun
    Xu Ke-xin
    Wang Yan
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27 (05) : 873 - 876
  • [6] Simulated Spectral Strategy to Enhance Numerical Tobacco Blending Based on Near-Infrared (NIR) Diffuse Reflectance Spectroscopy and Calibration Transfer
    Bin, Jun
    Wang, Zhiguo
    Du, Wen
    Zhong, Kejun
    Chen, Zengping
    [J]. ANALYTICAL LETTERS, 2023, 56 (12) : 1989 - 2003
  • [7] Near-infrared calibration transfer based on spectral regression
    Peng, Jiangtao
    Peng, Silong
    Jiang, An
    Tan, Jie
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2011, 78 (04) : 1315 - 1320
  • [8] Nonlinear calibration for near-infrared spectroscopy
    Dadhe, K
    [J]. CHEMICAL ENGINEERING & TECHNOLOGY, 2004, 27 (09) : 946 - 950
  • [9] NEAR-INFRARED (NIR) SPECTROSCOPY OF POLYMER BLENDS
    GHEBREMESKEL, Y
    GARTON, A
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 317 - POLY
  • [10] PLS Subspace-Based Calibration Transfer for Near-Infrared Spectroscopy Quantitative Analysis
    Zhao, Yuhui
    Yu, Jinlong
    Shan, Peng
    Zhao, Ziheng
    Jiang, Xueying
    Gao, Shuli
    [J]. MOLECULES, 2019, 24 (07):