Thermal analysis of phase change material encapsulated li-ion battery pack using multi-scale multi-dimensional framework

被引:20
|
作者
Hussain, Mazhar [1 ]
Khan, Mohd. Kaleem [1 ]
Pathak, Manabendra [1 ]
机构
[1] Indian Inst Technol Patna, Dept Mech Engn, Sustainable Energy Res Lab, Patna 801106, India
关键词
Li -ion battery; MSMD model; Phase change material; Battery cooling; Shorting; MANAGEMENT-SYSTEM; CELL; PERFORMANCE; MODULE; MODEL; OPTIMIZATION; SIMULATION; CONVECTION; BEHAVIOR; ISSUES;
D O I
10.1016/j.est.2023.107290
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Li-ion batteries are employed to propel Electric vehicles (EVs) and Hybrid Electric Vehicles (HEVs) into a clean and sustainable future. A battery pack experiences high heat generation under extreme and abusive conditions, which may lead to catastrophic thermal runaway. The present study proposes an efficient and economical Phase Change Material (PCM) based Battery Thermal Management System (BTMS) to avoid thermal runaway. A 3D simulation is performed on a single battery (1P1S) and a battery pack consisting of six batteries stacked in series (1P6S), with and without PCM, using the multi-scale multi-dimensional Newman, Tiedemann, Gu, and Kim (NTGK) model in ANSYS. The NTGK model analyzes the battery pack's discharge behavior and thermal per-formance. For PCM-based BTMS, the NTGK is coupled with the solidification and melting model. The effect of ambient temperature, discharge rate, and convective heat transfer coefficient on 1P1S and 1P6S battery packs with and without PCM is investigated under extreme and abusive conditions. The ambient temperature (Tamb) significantly impacts PCM selection and battery performance. The effective T-amb - PCM combinations are proposed for the optimal working of the battery pack. Under the extreme conditions of the fast-discharging rate, the PCM-based BTMS reduces the maximum battery temperature by 25.3 K and 19.5 K and improves the tem-perature uniformity by 5.3 K and 3.6 K at 5C and 4C discharge rates, respectively. Also, at Tamb of 300 K, the proposed PCM-based BTMS significantly reduces the maximum temperature by 60.4 K, 46 K, and 29.3 K when the external shorting resistance is 0.10, 0.15, and 0.25 omega, respectively. The proposed cooling system averts the thermal runaway when external shorting is 0.10 omega, and internal shorting is >0.1 mu omega. This research will be helpful in the further development of PCM-based thermal management systems for large-scale and commercial applications.
引用
收藏
页数:25
相关论文
共 50 条
  • [1] Analysis of ternary hybrid nanofluid in microchannel-cooled cylindrical Li-ion battery pack using multi-scale multi-domain framework
    Kumar, Kartik
    Sarkar, Jahar
    Mondal, Swasti Sundar
    APPLIED ENERGY, 2024, 355
  • [2] Optimization of Thermal Management System with Water and Phase Change Material Cooling for Li-Ion Battery Pack
    Li, Quanyi
    Cho, Jong-Rae
    Zhai, Jianguang
    ENERGIES, 2021, 14 (17)
  • [3] Multi-Scale Correlative Tomography of a Li-Ion Battery Composite Cathode
    Moroni, Riko
    Boerner, Markus
    Zielke, Lukas
    Schroeder, Melanie
    Nowak, Sascha
    Winter, Martin
    Manke, Ingo
    Zengerle, Roland
    Thiele, Simon
    SCIENTIFIC REPORTS, 2016, 6
  • [4] Multi-Scale Correlative Tomography of a Li-Ion Battery Composite Cathode
    Riko Moroni
    Markus Börner
    Lukas Zielke
    Melanie Schroeder
    Sascha Nowak
    Martin Winter
    Ingo Manke
    Roland Zengerle
    Simon Thiele
    Scientific Reports, 6
  • [5] Accelerated computational strategies for multi-scale thermal runaway prediction models in Li-ion battery
    Zhang, Pengfei
    Chen, Haipeng
    Yang, Kangbo
    Lu, Yiji
    Huang, Yuqi
    ENERGY, 2024, 305
  • [6] Multi-Scale and Multi-Dimensional Thermal Modeling of Lithium-Ion Batteries
    Gwak, Geonhui
    Ju, Hyunchul
    ENERGIES, 2019, 12 (03)
  • [7] Experimental Investigation of a New Passive Thermal Management System for a Li-Ion Battery Pack Using Phase Change Composite Material
    Malik, M.
    Dincer, I.
    Rosen, M.
    Fowler, M.
    ELECTROCHIMICA ACTA, 2017, 257 : 345 - 355
  • [8] Analytical modeling and optimization of phase change thermal management of a Li-ion battery pack
    Parhizi, Mohammad
    Jain, Ankur
    APPLIED THERMAL ENGINEERING, 2019, 148 : 229 - 237
  • [9] Li-Ion Battery Management Chip for Multi-Cell Battery Pack
    Ye, Yidie
    Chen, Chen
    Jin, Jin
    He, Lenian
    2008 IEEE ASIA PACIFIC CONFERENCE ON CIRCUITS AND SYSTEMS (APCCAS 2008), VOLS 1-4, 2008, : 534 - 537
  • [10] A multi-scale and multi-dimensional framework for enhancing the resilience of urban form to climate change
    Dhar, Tapan K.
    Khirfan, Luna
    URBAN CLIMATE, 2017, 19 : 72 - 91