In situ Sn isotope analysis of cassiterite (SnO2) by nanosecond laser ablation MC-ICP-MS

被引:9
|
作者
She, Jia-Xin [1 ,2 ]
Li, Weiqiang [1 ,2 ]
An, Shichao [1 ,2 ]
Yang, Tao [1 ]
Zhang, Rongqing [1 ]
机构
[1] Nanjing Univ, Sch Earth Sci & Engn, State Key Lab Mineral Deposits Res, Nanjing 210023, Jiangsu, Peoples R China
[2] Nanjing Univ, Frontiers Sci Ctr Crit Earth Mat Cycling, Nanjing, Peoples R China
关键词
U-PB GEOCHRONOLOGY; SOLUTION NEBULIZATION; RATIO DETERMINATION; FLUID EVOLUTION; TIN PROVINCE; FRACTIONATION; FEMTOSECOND; FE; RESOLUTION; CHEMISTRY;
D O I
10.1039/d3ja00010a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Stable Sn isotopes are emerging tracers for understanding the cycling of tin on Earth. Cassiterite, the most important Sn-bearing mineral in nature, commonly contains complex zoning and intergrowth textures that record the Sn mineralization history. Thus, in situ analysis of Sn isotopes in cassiterite could provide a powerful tool for deciphering Sn mineralization. In this study, we developed a method for in situ Sn isotopic analysis of cassiterite based on a nanosecond laser ablation system and a Nu 1700 Sapphire multi-collector inductively coupled plasma mass spectrometer (ns-LA-MC-ICP-MS). The laser ablation isotopic analyses were made by sample-standard bracketing with elemental doping of Sb introduced by solution nebulization. A newly developed large and homogeneous natural cassiterite crystal (lab ID: #cas17) was used as the matrix-matched bracketing standard for laser ablation analyses. To report in situ Sn isotope data with reference to the international Sn isotope reference material NIST 3161a, a simple and reliable method was developed to decompose cassiterite for precise and accurate Sn isotope analysis by solution nebulization MC-ICP-MS, and the delta Sn-122/118(3161a) of cassiterite "#cas17" was determined to be 0.36 +/- 0.02 parts per thousand. Based on a series of tests of different parameters (fluence, spot size, frequency, He gas flow rate, and ablation mode), the optimized analytical condition was found to be a 1 mu m s(-1) line scan with a laser spot size of 13 mu m and a laser fluence of 13.5 J cm(-2), firing at 5 Hz, in a He carrier gas flow at 760 ml min(-1). Under these conditions, the intermediate precision of the in situ Sn isotope analytical method was better than +/- 0.12 parts per thousand in delta Sn-122/118. Matrix effects from the trace elements of the natural cassiterite on measured Sn isotopic ratios were insignificant. The in situ Sn isotope analytical method was applied to different cassiterite samples, which yielded a range of 0.98 parts per thousand in delta Sn-122/118 among and within these cassiterite samples, and the laser ablation results were confirmed by the solution nebulization (SN) MC-ICP-MS analyses after dissolution. Our new method provides an efficient and effective approach for determining the Sn isotopic composition of cassiterite and could be applied to studies of Sn ore deposits.
引用
收藏
页码:1043 / 1056
页数:14
相关论文
共 50 条
  • [1] In Situ Carbon Isotope Analysis by Laser Ablation MC-ICP-MS
    Chen, Wei
    Lu, Jue
    Jiang, Shao-Yong
    Zhao, Kui-Dong
    Duan, Deng-Fei
    ANALYTICAL CHEMISTRY, 2017, 89 (24) : 13415 - 13421
  • [2] Solution and laser ablation MC-ICP-MS lead isotope analysis of gold
    Standish, Christopher
    Dhuime, Bruno
    Chapman, Robert
    Coath, Christopher
    Hawkesworth, Chris
    Pike, Alistair
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (02) : 217 - 225
  • [3] In situ Ti isotopic analysis by femtosecond laser ablation MC-ICP-MS
    Huang, Chao
    Wang, Hao
    Xie, Liewen
    Nie, Nicole X.
    Yang, Yueheng
    Zhao, Xinmiao
    Li, Jin
    Tian, Heng-Ci
    Wu, Shitou
    Xu, Lei
    Yang, Jinhui
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (10) : 2165 - 2175
  • [4] Lithium isotope analysis of natural and synthetic glass by laser ablation MC-ICP-MS
    le Roux, Petrus J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (07) : 1033 - 1038
  • [5] In Situ Ti Isotopic Measurements by Laser Ablation MC-ICP-MS
    Chen, Hsin-Wei
    Lee, Typhoon
    Lee, Der-Chuen
    Iizuka, Yoshiyuki
    TERRESTRIAL ATMOSPHERIC AND OCEANIC SCIENCES, 2009, 20 (05): : 703 - 712
  • [6] In situ Nd isotopic analysis of geological materials by laser ablation MC-ICP-MS
    Foster, GL
    Vance, D
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (03) : 288 - 296
  • [7] In situ Nd isotopic analysis of geological materials by laser ablation MC-ICP-MS
    Foster, Gavin L.
    Vance, Derek
    Journal of Analytical Atomic Spectrometry, 2006, 21 (03): : 288 - 296
  • [8] In-situ sulfur isotope ratio measurements by laser ablation high resolution MC-ICP-MS
    Lahaye, Y
    Bendall, C
    Brey, G
    Fiebig, J
    Weyer, S
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2004, 68 (11) : A69 - A69
  • [9] Laser ablation MC-ICP-MS:: Shedding new light on in-situ isotope ratio measurement
    Pearson, NJ
    Griffin, WL
    O'Reilly, SY
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (10) : A372 - A372
  • [10] Preparation of standards for in situ sulfur isotope measurement in sulfides using femtosecond laser ablation MC-ICP-MS
    Chen, Lu
    Chen, Kaiyun
    Bao, Zhian
    Liang, Peng
    Sun, Tiantian
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (01) : 107 - 116