Reference Ranges for Left Modified Myocardial Performance Index: Systematic Review and Meta-Analysis

被引:1
|
作者
Bligard, Katherine H. [1 ]
Doering, Michelle [2 ]
Porat, Shay [3 ,4 ]
Rosenbloom, Joshua I. [1 ,3 ]
机构
[1] Washington Univ, Sch Med, Dept Obstet & Gynecol, St Louis, MO 63130 USA
[2] Washington Univ, Sch Med, Bernard Becker Med Lib, St Louis, MO USA
[3] Hebrew Univ Jerusalem, Hadassah Med Org, Dept Obstet & Gynecol, Jerusalem, Israel
[4] Hebrew Univ Jerusalem, Fac Med, Jerusalem, Israel
关键词
Fetal cardiac function; Mod-MPI; Reference ranges; Echocardiography; Doppler; MOD-MPI SYSTEM; CARDIAC-FUNCTION; TEI-INDEX; REFERENCE VALUES; DOPPLER; ECHOCARDIOGRAPHY; RECIPIENTS; INTERVALS; OUTPUT;
D O I
10.1159/000535602
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Introduction: The modified myocardial performance index (mod-MPI) is a noninvasive Doppler-derived metric used to evaluate fetal cardiac function. However, the reference ranges for mod-MPI in normal fetuses are not clearly defined, which limits the use of this technology in fetuses with potential cardiac compromise. Thus, we aimed to perform a systematic review and meta-analysis of published mod-MPI reference ranges across gestation. Methods: The published literature was systematically searched, and all published articles in any language that provided values for the left ventricular mod-MPI obtained in low-risk, singleton fetuses were considered eligible for further review. All retrieved titles and abstracts were independently reviewed by two researchers. Mean and standard deviation by gestational week was extracted or calculated from published data. DerSimonian-Laird random-effects models were used to estimate pooled means and 95% confidence intervals (CIs). Results: The search resulted in 618 unique citations, of which 583 did not meet inclusion criteria, leaving 35 abstracts selected for full-text review. Review of the references of these 35 articles identified another 5 studies of interest. Of the 40 articles reviewed, six met inclusion criteria. There was significant heterogeneity seen in the mod-MPI results reported. Mod-MPI increased as pregnancy progressed in all studies. The pooled mean mod-MPI at 11 weeks' gestation was 0.400 (95% CI 0.374-0.426) and increased to 0.585 (95% CI 0.533-0.637) at 41 weeks' gestation. The increase was linear in 5 of 6 studies, while in 1 study, the mod-MPI was stable until 27 weeks' gestation, and then increased throughout the third trimester. Despite all having trends increasing over pregnancy, there was no study in which all the weekly means fell within the pooled 95% CI. Conclusion: While mod-MPI does increase over gestation, the true "reference ranges" for fetuses remain elusive. Future efforts to further optimize calculation of time intervals possibly via automation are desperately needed to allow for reproducibility of this potentially very useful tool to assess fetal cardiac function.
引用
收藏
页码:159 / 167
页数:9
相关论文
共 50 条
  • [1] Turkish reference ranges for the left fetal modified myocardial performance index
    Yakut, Kadriye
    Ocal, Doga Fatma
    Ozturk, Filiz
    Ozturk, Merve
    Sanhal, Cem Yasar
    Celen, Sevki
    Ustun, Yaprak
    TURKISH JOURNAL OF PEDIATRICS, 2021, 63 (06) : 1038 - 1047
  • [2] Reference Ranges for Vermis Biometry on Prenatal Ultrasound: Systematic Review and Meta-Analysis
    Rosenbloom, Joshua, I
    Yaeger, Lauren H.
    Porat, Shay
    ULTRASCHALL IN DER MEDIZIN, 2023, 44 (01): : E25 - E38
  • [3] Echocardiographic reference ranges of myocardial work in children and adolescents: A meta-analysis
    Jacquemyn, Xander
    Barnes, Benjamin T.
    Rao, Sruti
    Kutty, Shelby
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2025, 424
  • [4] Left atrial volume index as a predictor of outcome in patients with acute myocardial infarction: a systematic review and meta-analysis
    Bytyci, I. Ibadete
    Bajraktari, G.
    EUROPEAN JOURNAL OF HEART FAILURE, 2017, 19 : 125 - 126
  • [5] Development of Australian Reference Ranges for the Left Fetal Modified Myocardial Performance Index and the Influence of Caliper Location on Time Interval Measurement
    Meriki, N.
    Welsh, A. W.
    FETAL DIAGNOSIS AND THERAPY, 2012, 32 (1-2) : 87 - 95
  • [6] CT for the evaluation of myocardial extracellular volume with MRI as reference: a systematic review and meta-analysis
    Zhang, Hui
    Guo, Huimin
    Liu, Guangyao
    Wu, Chuang
    Ma, Yurong
    Li, Shilan
    Zheng, Yurong
    Zhang, Jing
    EUROPEAN RADIOLOGY, 2023, 33 (12) : 8464 - 8476
  • [7] CT for the evaluation of myocardial extracellular volume with MRI as reference: a systematic review and meta-analysis
    Hui Zhang
    Huimin Guo
    Guangyao Liu
    Chuang Wu
    Yurong Ma
    Shilan Li
    Yurong Zheng
    Jing Zhang
    European Radiology, 2023, 33 : 8464 - 8476
  • [8] Myocardial Performance Index to assess cardiac function in autoimmune connective tissue disease: a systematic review and meta-analysis
    Hidayat, Rudy
    Nasution, Sally Aman
    Parlindungan, Faisal
    Dalimunthe, Naomi Niari
    Alvianto, Steven
    Widjanarko, Nicolas Daniel
    Kultsum, Ummi
    Efendi, Cristopher
    Gotama, Yovita
    LUPUS SCIENCE & MEDICINE, 2024, 11 (02):
  • [9] Third Trimester Myocardial Performance Index in Fetuses from Women with Hyperglycemia in Pregnancy: A Systematic Review and Meta-Analysis
    Sirico, Angelo
    Raffone, Antonio
    Maruotti, Giuseppe Maria
    Travaglino, Antonio
    Paciullo, Carmela
    Diterlizzi, Alice
    Mollo, Antonio
    Rizzo, Giuseppe
    Zullo, Fulvio
    Lanzone, Antonio
    ULTRASCHALL IN DER MEDIZIN, 2023, 44 (02): : e99 - e107
  • [10] Normal Ranges of Left Atrial Strain by Speckle-Tracking Echocardiography: A Systematic Review and Meta-Analysis
    Pathan, Faraz
    D'Elia, Nicholas
    Nolan, Mark T.
    Marwick, Thomas H.
    Negishi, Kazuaki
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (01) : 59 - U143