Effect of different activation methods on the intratubular penetration of CaOH2 paste: Ex-vivo analysis by confocal laser scanning microscopy

被引:1
|
作者
Gasparin Tadano, Joao Pedro [1 ]
da Silveira Bueno, Carlos Eduardo [1 ]
de Magalhaes Silveira, Claudia Fernandes [1 ]
Yamanaka, Tainara Bielecki [1 ]
Piai, Gabriela Goncalez [2 ]
Hungaro Duarte, Marco Antonio [2 ]
Vivan, Rodrigo Ricci [2 ]
De Martin, Alexandre Sigrist [1 ]
机构
[1] Fac Sao Leopoldo Mandic, Inst Pesquisas Sao Leopoldo Mandic, Endodontia, Campinas, SP, Brazil
[2] Univ Sao Paulo, Sch Dent Bauru, Dept Restorat Dent Endodont & Dent Mat, Bauru, SP, Brazil
关键词
calcium hydroxide; confocal laser scanning microscope; molar; root canal medicaments; root canal treatment; PASSIVE ULTRASONIC IRRIGATION; CALCIUM HYDROXIDE PASTES; ENTEROCOCCUS-FAECALIS; ROOT CANALS; IN-VITRO; DIFFUSION; REMOVAL; PH;
D O I
10.1111/aej.12685
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to evaluate the maximum penetration depth (MPD) and penetration area (PA) of CaOH2 paste agitated by different methods and to measure the pH after performing these methods. Fifty-five mandibular premolars were divided into control, GL and 4 experimental groups, GEC, GXP, GEDDY and GI (n =11), where the paste was agitated with Easy Clean, XP-endo Finisher, EDDY and Irrisonic, respectively. The canals were instrumented and irrigated with NaOCl. The paste was manipulated with propylene glycol and rhodamine B dye. Root sections were examined using confocal laser scanning microscopy. There was no difference between groups regarding PA (p > 0.05). At 5 mm, MPD was greater in GEC than in GL or GEDDY, and greater in GI than in GL (p < 0.05). At 2 mm, MPD was greater in GEC than in the other groups (p < 0.05). In conclusion, both Easy Clean and Irrisonic promoted deeper paste penetration and were associated with higher pH levels.
引用
收藏
页码:18 / 26
页数:9
相关论文
共 23 条
  • [1] Innovative Possibilities of the intraoperative Tissue Examination by means of ex-vivo confocal Laser Scanning Microscopy
    Hartmann, D.
    von Braunmuehl, T.
    JOURNAL DER DEUTSCHEN DERMATOLOGISCHEN GESELLSCHAFT, 2016, 14 (11): : 1184 - 1185
  • [2] Diagnosis of Basal Cell Carcinoma with Ex-vivo Confocal Laser Scanning Microscopy in a Real-life Setting
    Forchhammer, Stephan
    Grunewald, Sonja
    Moehrle, Matthias
    Metzler, Gisela
    Eigentler, Thomas
    Muench, Anne-Kristin
    Ogrzewalla, Hanna
    ACTA DERMATO-VENEREOLOGICA, 2023, 103
  • [3] Evaluation of the effect of calcium hydroxide paste on sealer penetration into dentinal tubules by confocal laser scanning microscopy
    Kanmaz, Fatma
    Altunbas, Demet
    AUSTRALIAN ENDODONTIC JOURNAL, 2022, 48 (01) : 82 - 90
  • [4] Effect of Different Irrigation Activation Techniques on Sealer Penetration: A Confocal Laser Microscopy Study
    Aydin, Zeliha Ugur
    Kosumcu, Sevim
    Meseci, Busra
    CHINESE JOURNAL OF DENTAL RESEARCH, 2021, 24 (02): : 113 - 118
  • [5] Ex-vivo confocal Laser Scanning Microscopy: Main Characteristics of healthy Skin and melanocytic Tumors and Correlation with conventional Histology
    Hartmann, D.
    Ruini, C.
    Mathemeier, L.
    Dietrich, A.
    Berking, C.
    Ruzicka, T.
    von Braunmuehl, T.
    JOURNAL DER DEUTSCHEN DERMATOLOGISCHEN GESELLSCHAFT, 2015, 13 : 57 - 57
  • [6] Analysis of tubulin transport in squid giant axons ex vivo using confocal laser scanning microscopy
    Terada, S
    Hirokawa, N
    MOLECULAR BIOLOGY OF THE CELL, 1999, 10 : 370A - 370A
  • [7] Evaluating the effect of different irrigation activation techniques on the dentin tubules penetration of two different root canal sealers by laser scanning confocal microscopy
    Kaplan, Fatma
    Erdemir, Ali
    MICROSCOPY RESEARCH AND TECHNIQUE, 2023, 86 (07) : 791 - 802
  • [8] Ex vivo confocal laser scanning microscopy for bullous pemphigoid diagnostics II: indirect immunofluorescence with two different substrates
    Bagci, I. S.
    Erguen, E. Z.
    Aoki, R.
    Krammer, S.
    Vladimirova, G.
    Sardy, M.
    Ruzicka, T.
    French, L. E.
    Hartmann, D.
    EXPERIMENTAL DERMATOLOGY, 2023, 32 (04) : E75 - E75
  • [9] Efficacy of different irrigation methods on dentinal tubule penetration of Chlorhexidine, QMix and Irritrol: A confocal laser scanning microscopy study
    Kucuk, Meltem
    Kermeoglu, Fatma
    AUSTRALIAN ENDODONTIC JOURNAL, 2019, 45 (02) : 202 - 208
  • [10] The effect of different obturation methods on sealer penetration alongside apically separated rotary nickel-titanium instruments: A confocal laser scanning microscopy study
    Aktemur Turker, Sevinc
    Uzunoglu Ozyurek, Emel
    Tek, Vildan
    MICROSCOPY RESEARCH AND TECHNIQUE, 2020, 83 (06) : 720 - 726