Correlation relationships of the reentrant ventricular tachycardia circuit

被引:2
|
作者
Ciaccio, Edward J. [1 ,2 ,4 ]
Coromilas, James [3 ]
Wan, Elaine Y. [1 ]
Yarmohammadi, Hirad [1 ]
Saluja, Deepak S. [1 ]
Peters, Nicholas S. [2 ]
Garan, Hasan [1 ]
Biviano, Angelo B. [1 ]
机构
[1] Columbia Univ, Dept Med, Div Cardiol, Coll Phys & Surg, New York, NY USA
[2] Imperial Coll London, Imperial Ctr Cardiac Engn, ElectroCardioMaths Programme, London, England
[3] Rutgers State Univ, Dept Med, Div Cardiovasc Dis & Hypertens, New Brunswick, NJ USA
[4] Columbia Univ, HP 7-742, 180 Ft Washington Ave, New York, NY 10032 USA
关键词
Activation mapping; Isthmus; Reentrant circuit; Sinus rhythm; Ventricular tachycardia; CYCLE LENGTH; SUBSTRATE; ISTHMUS; STIMULATION; ACTIVATION; INFARCTION; SYSTEM;
D O I
10.1016/j.cmpb.2023.107764
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Introduction: A quantitative analysis of the components of reentrant ventricular tachycardia (VT) circuitry could improve understanding of its onset and perpetuation.Method: In 19 canine experiments, the left anterior descending coronary artery was ligated to generate a subepicardial infarct. The border zone resided at the epicardial surface of the anterior left ventricle and was mapped 3-5 days postinfarction with a 196-312 bipolar multielectrode array. Monomorphic VT was inducible by extrastimulation. Activation maps revealed an epicardial double-loop reentrant circuit and isthmus, causing VT. Several circuit parameters were analyzed: the coupling interval for VT induction, VT cycle length, the lateral isthmus boundary (LIB) lengths, and isthmus width and angle.Results: The extrastimulus interval for VT induction and the VT cycle length were strongly correlated (p < 0.001). Both the extrastimulus interval and VT cycle length were correlated to the shortest LIB (p < 0.005). A derivation was developed to suggest that when conduction block at the shorter LIB is functional, the VT cycle length may depend on the local refractory period and the delay from wavefront pivot around the LIB. Isthmus width and angle were uncorrelated to other parameters.Conclusions: The shorter LIB is correlated to VT cycle length, hence its circuit loop may drive reentrant VT. The extrastimulation interval, VT cycle length, and shorter LIB are intertwined, and may depend upon the local refractory period. Isthmus width and angle are less correlated, perhaps being more related to electrical discontinuity caused by alterations in infarct shape at depth.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] PREFERENTIAL EFFECT OF PROCAINAMIDE ON THE REENTRANT CIRCUIT OF VENTRICULAR-TACHYCARDIA
    KAY, GN
    EPSTEIN, AE
    PLUMB, VJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (02) : 382 - 390
  • [2] CORRELATION OF SINUS ACTIVATION TIME WITH REENTRANT VENTRICULAR-TACHYCARDIA
    ASSADI, MA
    GOUGH, W
    ELSHERIF, N
    CLINICAL RESEARCH, 1988, 36 (05): : A784 - A784
  • [3] ACTIONS OF ANTIARRHYTHMIC DRUG ON THE REENTRANT CIRCUIT OF SUSTAINED VENTRICULAR-TACHYCARDIA
    AIZAWA, Y
    CHINUSHI, M
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1992, 56 : 1470 - 1473
  • [4] SPATIAL ORIENTATION AT THE REENTRANT CIRCUIT AT IDIOPATHIC LEFT-VENTRICULAR TACHYCARDIA
    AIZAWA, Y
    CHINUSHI, M
    KITAZAWA, H
    WASHIZUKA, T
    TAKAHASHI, K
    SHIBA, M
    OHHIRA, K
    ABE, A
    SHIBATA, A
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (04): : 316 - 319
  • [5] Remodeling in cells from different regions of the reentrant circuit during ventricular tachycardia
    Baba, S
    Dun, W
    Cabo, C
    Boyden, PA
    CIRCULATION, 2005, 112 (16) : 2386 - 2396
  • [6] VENTRICULAR-TACHYCARDIA WITH 2 POSSIBLE EXITS FROM ONE REENTRANT CIRCUIT
    EBE, K
    AIZAWA, Y
    SATOH, M
    FUNAZAKI, T
    MIYAJIMA, S
    NIWANO, S
    TAMURA, M
    SHIBATA, A
    MIYAMURA, H
    EGUCHI, S
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1990, 54 (02): : 214 - 219
  • [7] CHARACTERISTICS OF ENDOCARDIAL ELECTROGRAMS IN THE CRITICAL REGION OF THE REENTRANT CIRCUIT IN VENTRICULAR-TACHYCARDIA
    SAITO, J
    DOWNAR, E
    DOIG, JC
    HARRIS, L
    MICKLEBOROUGH, L
    KIMBER, S
    MASSE, S
    SEVAPTSIDIS, E
    SHI, MH
    CHEN, TCK
    CIRCULATION, 1994, 90 (04) : 340 - 340
  • [8] Optical mapping of the functional reentrant circuit of ventricular tachycardia in acute myocardial infarction
    Takahashi, T
    van Dessel, P
    Lopshire, JC
    Groh, WJ
    Miller, J
    Wu, JY
    Zipes, DP
    HEART RHYTHM, 2004, 1 (04) : 451 - 459
  • [9] ENTRAINMENT ONSET IN A PACEMAKER MODEL OF REENTRANT VENTRICULAR-TACHYCARDIA - INSIGHT INTO LOCALIZATION OF CRITICAL ELEMENTS OF A REENTRANT CIRCUIT
    KREMERS, MS
    WELLS, PJ
    BLACK, WH
    MCBRIDE, W
    ZMIJEWSKI, M
    TAYLOR, AL
    ECKELS, R
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (05): : 631 - 638
  • [10] Ventricular tachycardia associated with bidirectional reentrant circuit around the tricuspid annulus in arrhythmogenic right ventricular dysplasia
    Noda, T
    Suyama, K
    Shimizu, W
    Satomi, K
    Otomo, K
    Nakagawa, E
    Kurita, T
    Aihara, N
    Kamakura, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (10): : 2050 - 2051