Assessment and Correction of the Spectral Quality for the Savart Polarization Interference Imaging Spectrometer

被引:0
|
作者
Han, Zhongyi [1 ]
Gao, Peng [1 ]
Ai, Jingjing [1 ]
Liu, Gongju [1 ]
Xiao, Hanlin [1 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Math & Phys Sci, Qingdao 266061, Peoples R China
关键词
Optical path difference; Savart polarization interference imaging spectrometer; Spectral quality calibration; CALIBRATION;
D O I
10.3807/COPP.2023.7.5.518
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
As an effective means of remotely detecting the spectral information of the object, the spectral calibration for the Savart polarization interference imaging spectrometer (SPIIS) is a basis and prerequisite of information quantification, and its experimental calibration scheme is firstly proposed in this paper. In order to evaluate the accuracy of the spectral information acquisition, the linear interpolation, cubic spline interpolation, and piecewise cubic interpolation algorithms are adopted, and the precision of the quadratic polynomial fitting is the highest, whose fitting error is better than 5.8642 nm in the wavelength range of [500 nm, 820 nm]. Besides, the inversed value of the spectral resolution for the monochromatic light is greater than the theoretical value, and the deviation between them becomes larger with the wavelength increasing, which is mainly caused by the structural design of the SPIIS, together with the rationality of the spectral restoration algorithm and the selection of the maximum optical path difference (OPD). This work demonstrates that the SPIIS has achieved high performance assuring the feasibility of its practical use in various fields.
引用
收藏
页码:518 / 528
页数:11
相关论文
共 50 条
  • [1] The transmittance of Savart polariscope in polarization interference imaging spectrometer
    Peng Zhi-Hong
    Zhang Chun-Min
    Zhao Bao-Chang
    Li Ying-Cai
    Wu Fu-Quan
    ACTA PHYSICA SINICA, 2006, 55 (12) : 6374 - 6381
  • [2] Image quality and spectral performance evaluations of a polarization imaging spectrometer based on a Savart polariscope
    Ai, Jingjing
    Gao, Peng
    Chen, Qingying
    Zhang, Shuaiyi
    APPLIED OPTICS, 2017, 56 (21) : 5933 - 5938
  • [3] Analysis of the clear aperture of Savart plates in polarization interference imaging spectrometer
    Li Qi-Wei
    Zhang Chun-Min
    Wei Yu-Tong
    Chen Qing-Ying
    ACTA PHYSICA SINICA, 2015, 64 (22)
  • [4] Novel polarization interference imaging spectrometer with adjustable lateral displacement Savart polariscope
    School of Science, Xi'an Jiaotong University, Xi'an 710049, China
    不详
    Guangxue Xuebao, 2007, 4 (643-646):
  • [5] Influences of the thickness, misalignment, and dispersion of the Savart polariscope on the optical path difference and spectral resolution in the polarization interference imaging spectrometer
    Zhang, Chunmin
    Zhao, Jianke
    Sun, Yao
    APPLIED OPTICS, 2011, 50 (20) : 3497 - 3504
  • [6] A static polarization imaging spectrometer based on a Savart polariscope
    Zhang, CM
    Bin, XL
    Zhao, BC
    Yuan, XJ
    OPTICS COMMUNICATIONS, 2002, 203 (1-2) : 21 - 26
  • [7] Analysis of the transmittance of modified Savart polariscope in the static large field of view polarization interference imaging spectrometer
    Du Juan
    Zhang Chun-Min
    Zhao Bao-Chang
    Sun Yao
    ACTA PHYSICA SINICA, 2008, 57 (10) : 6311 - 6318
  • [8] Analysis of the transmittance of modified Savart polariscope in the static large field of view polarization interference imaging spectrometer
    Du, Juan
    Zhang, Chun-Min
    Zhao, Bao-Chang
    Sun, Yao
    Wuli Xuebao/Acta Physica Sinica, 2008, 57 (10): : 6311 - 6318
  • [9] Polarization detection with polarization interference imaging spectrometer
    Jian, Xiaohua
    Zhang, Chunmin
    Zhao, Baochang
    OPTIK, 2011, 122 (08): : 677 - 680
  • [10] Polarization measurement using polarization interference imaging spectrometer
    Jian Xiao-Hua
    Zhang Chun-Min
    Zhu Bao-Hui
    Zhao Bao-Chang
    Du Juan
    ACTA PHYSICA SINICA, 2008, 57 (12) : 7565 - 7570