Usefulness of optic nerve sheath diameter measurement in hypertensive patients during pregnancy and the puerperium

被引:2
|
作者
Gutierrez, Hedgar Berty [1 ]
Gonzalez, Elier Carrera [2 ]
机构
[1] Clin Surg Univ Hosp Miguel Enriquez, Intens Care Unit, Degree Specialist Intens & Emergency Med 2, Havana, Cuba
[2] Clin Surg Univ Hosp Miguel Enriquez, Intens Care Unit, Bachelor Nursing, Master Med Emergencies, Havana, Cuba
来源
关键词
Pre-eclampsia; eclampsia; intracranial hypertension; ocular ultrasonography; optic nerve sheath; INTRACRANIAL-PRESSURE; ULTRASOUND;
D O I
10.1080/14767058.2023.2187253
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Pre-eclampsia/eclampsia during pregnancy and the puerperium are major risk factors for maternal and perinatal morbidity and mortality worldwide. Early diagnosis followed by appropriate treatment can prevent neurological disorders, considered one of the most serious sequelae of the disease. The detection of increased intracerebral pressure through the use of ocular ultrasonography could be considered an effective method for its diagnosis, since it has the advantage of being a noninvasive technique, easy to perform at the patient's bedside and with a high sensitivity and specificity for the detection of intracranial hypertension.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Measurement of Optic Nerve Sheath Diameter to Detect Increased Intracranial Pressure in Hypertensive Patients
    Dikmetas, Cesareddin
    Ergin, Mehmet
    Duman, Cigdem Savas
    Gulpembe, Mustafa
    Acar, Tarik
    Yavuz, Kenan
    Cander, Basar
    Girisgin, Sadik
    Kocak, Sedat
    EURASIAN JOURNAL OF EMERGENCY MEDICINE, 2020, 19 (01) : 40 - 45
  • [2] The measurement of ultrasonographic optic nerve sheath diameter in patients with hyperglycemia
    Donertas, Eda
    Kozaci, Nalan
    Avci, Mustafa
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2022, 29 (03) : 137 - 143
  • [3] Bias in the measurement of optic nerve sheath diameter
    Hossein-Nejad, Hooman
    Bahreini, Maryam
    Rasooli, Fatemeh
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (02): : 323 - 324
  • [4] Ultrasound optic nerve sheath diameter measurement in optic neuritis
    De Bernardo, Maddalena
    Vitiello, Livio
    Kumar, Akshay
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2019, 37 (08): : 1595 - 1596
  • [5] Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults
    Han Chen
    Gui-Sheng Ding
    Yan-Chun Zhao
    Rong-Guo Yu
    Jian-Xin Zhou
    BMC Neurology, 15
  • [6] Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults
    Chen, Han
    Ding, Gui-Sheng
    Zhao, Yan-Chun
    Yu, Rong-Guo
    Zhou, Jian-Xin
    BMC NEUROLOGY, 2015, 15
  • [7] Sonographic measurement of the optic nerve sheath diameter at height
    Kunze, Georg
    FLUGMEDIZIN TROPENMEDIZIN REISEMEDIZIN, 2023, 30 (06): : 269 - 270
  • [8] Optic Nerve Sheath Diameter Measurement During Diabetic Ketoacidosis: A Pilot Study
    Bergmann, Kelly R.
    Milner, Donna M.
    Voulgaropoulos, Constantinos
    Cutler, Gretchen J.
    Kharbanda, Anupam B.
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2016, 17 (05) : 531 - 541
  • [9] Real time optic nerve sheath diameter measurement during lumbar puncture
    Hassen, Getaw Worku
    Al-Juboori, Mohammed
    Koppel, Barbara
    Akfirat, Gokhan
    Kalantari, Hossein
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (04): : 736.e1 - 736.e3
  • [10] Ultrasonographic measurement of the optic nerve sheath diameter in dysthyroid optic neuropathy
    Xian Ji
    Wei Xiao
    Huijing Ye
    Rongxin Chen
    Jinghong Wu
    Yuxiang Mao
    Huasheng Yang
    Eye, 2021, 35 : 568 - 574