Development and Evaluation of a Portable MVT-Based All-Digital Helmet PET Scanner

被引:2
|
作者
Zhou, Feng [1 ]
D'Ascenzo, Nicola [1 ,2 ,3 ]
Zhang, Bo [1 ]
Antonecchia, Emanuele [1 ]
Fang, Lei [1 ]
Ba, Li [4 ]
Zhang, Min [4 ]
Zhu, Xiaohua [5 ]
Liu, Qiong [6 ]
Ni, Jiazuan [6 ]
Frati, Giacomo [3 ,7 ]
Kreissl, Michael [8 ]
Chen, Xun [9 ]
Wu, Jiang [10 ]
Xie, Qingguo [9 ,11 ,12 ]
机构
[1] Huazhong Univ Sci & Technol, Dept Biomed Engn, Wuhan 430074, Peoples R China
[2] Univ Sci & Technol China, Dept Elect Engn & Informat Sci, Hefei 230026, Peoples R China
[3] Ist Neurol Mediterraneo NEUROMED IRCCS, Dept Med Phys & Engn, I-86077 Pozzilli, Italy
[4] Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Neurol, Wuhan 430074, Peoples R China
[5] Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Nucl Med, Wuhan 430074, Peoples R China
[6] Shenzhen Univ, Coll Life Sci & Oceanog, Shenzhen 518055, Peoples R China
[7] Sapienza Univ Rome, Dept Clin Internal Med Anesthesiol & Cardiovasc Sc, I-00185 Rome, Italy
[8] Otto von Guericke Univ, Univ Hosp Magdeburg, Dept Radiol & Nucl Med, D-39106 Magdeburg, Germany
[9] Univ Sci & Technol China, Dept Elect Engn & Informat Sci, Hefei 230026, Peoples R China
[10] Univ Elect Sci & Technol China, Inst Fundamental & Frontier Sci, Chengdu 611731, Peoples R China
[11] Huazhong Univ Sci & Technol, Dept Biomed Engn, Wuhan 430074, Peoples R China
[12] Wuhan Natl Lab Optoelect, Wuhan 430074, Peoples R China
关键词
Advanced diagnostics; helmet brain positron emission tomography; hemispherical detector arrangement; multi voltage threshold (MVT); portable positron emission tomography;
D O I
10.1109/TRPMS.2024.3357571
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Novel design solutions for dedicated portable brain positron emission tomography systems with improved performance facilitate emergency and interventional image-guided surgery as well as advanced diagnostics of clinically impaired patients with neurodegenerative diseases. We report a novel portable MVT-based All-Digital helmet PET system with a hemispherical detector arrangement based on the Multi Voltage Threshold technology. It has a transverse and axial field of view (FOV) of 200 and 124 mm, respectively. It allows to scan subjects in a standing, sitting, and lying position. We evaluated the performance of the system according to NEMA standards. The scanner exhibits a noise equivalent count rate peak of (151 +/- 2) kcps at the activity of 40.65 kBq/mL, a sensitivity of (55.24 +/- 0.05) cps/kBq, and a spatial resolution at the center of the FOV of approximately 3.3 mm (FWHM), when using the filtered back projection algorithm. For a mini Derenzo phantom, rods of 2.0-mm diameter can be clearly separated. Time-dynamic ( )[F-18 ]-Fluorodeoxyglucose human brain imaging was performed, showing the distinctive traits of cortex and thalamus uptake, as well as of the arterial and venous flow with 30 s time frames. We finally verified the usability of the device in the diagnostics of Alzheimer's Disease by imaging human subjects with [F-18 ]-Florbetapir.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 50 条
  • [1] An MVT based all-digital DAQ for energy determination
    Lin, Li
    Long, Anwen
    Xiao, Peng
    Liu, Shihao
    Jiang, Hao
    Dai, Erpeng
    Xie, Qingguo
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1024 - 1027
  • [2] Energy Calibration of MVT Digitizers in All-Digital Gamma Cameras
    Qiu, Ao
    Wan, Lin
    Ling, Yiqing
    Xie, Qingguo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2023, 70 (05) : 847 - 852
  • [3] Development and Evaluation of a Prototype of Shape-Adaptable and Portable All-Digital PET System for In-Lab and In-Field Plant Imaging
    Antonecchia, Emanuele
    D'Ascenzo, Nicola
    Cantalamessa, Silvia
    Chang, Weike
    Ciardiello, Mariachiara
    Kattan, Michelle
    Nematpour, Afsaneh
    Pagnani, Giancarlo
    Palazzo, Federica
    Punzet, Daniel
    Shen, Geer
    Zhou, Feng
    Pisante, Michele
    Xie, Qingguo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2024, 71 (01) : 113 - 120
  • [4] A simple all-digital PET system
    Xie, Qingguo
    Kao, Chien-Min
    Xia, Rongsheng
    Wang, Xi
    Li, Na
    Jiang, Xin
    Zhi, Li
    Zhang, Zhi
    Deng, Zhonghua
    Chen, Chin-Tu
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [5] Development and evaluation of a new high-TOF-resolution all-digital brain PET system
    Fang, Lei
    Zhang, Bo
    Li, Bingxuan
    Zhang, Xiangsong
    Zhou, Xiaoyun
    Yang, Jigang
    Li, Ang
    Shi, Xinchong
    Liu, Yuqing
    Kreissl, Michael
    D'Ascenzo, Nicola
    Xiao, Peng
    Xie, Qingguo
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (02):
  • [6] A New Solution of Time Synchronization in All-Digital PET based on TDC
    Fang, Lei
    Zhang, Bo
    Yan, Li
    Dai, Jian
    Wang, Weidong
    Xie, Qingguo
    Li, Jing
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [7] A portable all-digital pulsewidth control loop for SOC applications
    Wang, Wei
    Wey, I-Chyn
    Wu, Chia-Tsun
    Wu, An-Yeu Andy
    2006 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-11, PROCEEDINGS, 2006, : 3165 - +
  • [8] Initial Implementation of All-Digital PET DAQ System
    Wang, Xi
    Xie, Qingguo
    Chen, Yuanbao
    Niu, Ming
    Wu, Zhongyi
    Zhu, Jun
    Xi, Daoming
    Gao, Junxiong
    Wang, Yunbo
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2500 - 2503
  • [9] An investigation of digital signal processing for shaped pulses for all-digital PET
    Xie, Qingguo
    Zhu, Jun
    Wang, Xi
    Zhang, Bo
    Zhu, Caigang
    Guo, Ning
    Zhang, Zhi
    Chen, Chin-Tu
    Wah, Yau W.
    Bogdan, Mircea
    Kao, Chien-Min
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [10] Feasibility Study of All-digital PET Monitoring Proton Therapy
    Gao, Min
    Kao, Chien-Min
    Chen, Hsien-Hsin
    Lyu, Xudong
    Hong, Ji-Hong
    Hua, Yuexuan
    Yen, Tzu-Chen
    Xie, Qingguo
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,