Lumbar Pedicle Morphometry of Dry Vertebral Columns in Relation to Transpedicular Fixation: A Cross-Sectional Study From Central India

被引:1
|
作者
Verma, Virendra [1 ]
Sr, Udit Agrawal [1 ]
机构
[1] All India Inst Med Sci, Orthoped, Bhopal, India
关键词
vertebrae; pedicle screw; lumbar; anatomy; pedicle; COMPUTED-TOMOGRAPHY; POPULATION; SPINE;
D O I
10.7759/cureus.38108
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The lumbar vertebrae are the largest vertebrae of the vertebral column, which support the maximum body weight. There has been an increased focus on transpedicular spinal fixation for addressing various lumbar spine pathology. However, its safety and efficacy require precise knowledge of the lumbar pedicle anatomy. Mismatched size of screw and pedicle may lead to failure of instrumentation. It may result in cortex perforation or pedicle fracture and loosening of the pedicle screw. The oversizing of the pedicle screw can result in dural tears, leakage of the cerebrospinal fluid, and injuries to the nerve root. As the racial variations in the anatomy of a pedicle are well known, this study was performed to assess the morphological parameters of the lumbar vertebrae pedicles in the Central Indian population so that the appropriate sizes of pedicular implants can be selected.Material and methods: The present study was conducted at a tertiary-level hospital and medical college on dry lumbar vertebrae specimens available in the department of anatomy. The measurement of morphometric parameters of the lumbar vertebrae pedicles was performed in 20 dry lumbar specimens using vernier calipers and a standard goniometer. The morphometric parameters included in the study are pedicle transverse external diameter (pedicle width), pedicle sagittal external diameter (pedicle height), transverse angle of the pedicle, and sagittal angle of the pedicle. Statistical analysis was performed using Statistical Package for the Social Sciences (SPSS) system version 25 (Chicago, IL: SPSS Inc.). Results: The broadest external transverse diameter was at the L5 level, with a mean of (17.54 +/- 1.6 mm) in the lumbar vertebrae. The broadest external sagittal pedicle diameter was at the L1 level (13.7 +/- 0.88 mm). The maximum transverse angle of the pedicle was at L5 with a mean of 25.39 +/- 3.10 degrees. The maximum sagittal angle was at L1 with a mean of 5.44 +/- 0.71 degrees.Conclusion: The increased concern regarding the internal fixation of the spine with pedicle screw systems created the need to have almost accurate anatomical knowledge of lumbar pedicles. Due to the dynamic nature of the lumbar spine and the body's load, maximum degeneration occurs at this spine segment, making it the most commonly operated region of the vertebral column. In our study, pedicle dimensions are comparable to populations of other Asian countries. However, the pedicle dimension of our population is lower than the White American population. This morphological variation of pedicle anatomy will help surgeons choose appropriate size screws and optimum angulations to insert the implant, decreasing complications.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Thoracic Pedicle Morphometry of Dry Vertebral Columns in Relation to Trans-Pedicular Fixation: A Cross-Sectional Study From Central India
    Verma, Virendra
    Santoshi, John A.
    Jain, Vaibhav
    Patel, Manmohan
    Dwivedi, Manish
    Nagar, Manoj
    Selvanayagam, Rajkumar
    Pal, Dharm
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (05)
  • [2] The MRI of Lumbar Vertebral Canal in Low Back Pain: A Cross-Sectional Study
    Badaam, Asim Mohsin
    Sukre, Shivaji B.
    Hashmi, Syed Sajjad Ali
    Shaikh, Siraj Ahmed Hasham
    Hiware, Sanket Dadarao
    Jawaduddin, Khwaja Moizuddin
    Daimi, Syed Rehan H.
    Siddiqui, Faiza Banu
    Ali, Mohammed Taher
    Badaam, Khaled M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [3] Morphology and Morphometry of Mental Foramen in Dry Adult South Indian Mandibles: A Cross-Sectional Study
    Lalitha, B.
    Rao, Ephraim Vikram
    INTERNATIONAL JOURNAL OF SCIENTIFIC STUDY, 2016, 4 (03) : 140 - 142
  • [4] Vertebral morphometry by X-ray absorptiometry before and after liver transplant: a cross-sectional study
    Giannini, S
    Nobile, M
    Carbonare, LD
    Ciuffreda, M
    Germoni, V
    Iemmolo, RM
    Gerunda, GE
    Sartori, L
    Crepaldi, G
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2001, 13 (10) : 1201 - 1207
  • [5] Characteristics of perinatal depression in rural central, India: a cross-sectional study
    Sujit D. Rathod
    Simone Honikman
    Charlotte Hanlon
    Rahul Shidhaye
    International Journal of Mental Health Systems, 12
  • [6] Characteristics of perinatal depression in rural central, India: a cross-sectional study
    Rathod, Sujit D.
    Honikman, Simone
    Hanlon, Charlotte
    Shidhaye, Rahul
    INTERNATIONAL JOURNAL OF MENTAL HEALTH SYSTEMS, 2018, 12
  • [7] Role of Patch Testing in Facial Contact Dermatitis: A Cross-Sectional Study from Central India
    Yadav, Hitesh
    Ganguly, Satyaki
    Singh, Ajeet
    INDIAN DERMATOLOGY ONLINE JOURNAL, 2024, 15 (02) : 242 - 246
  • [8] Morphometric analysis of the Proximal End of the Dry Adult Tibia : A Cross-sectional Study from Eastern India
    Pradhan, Rashmi Rani
    Korukonda, Sushma
    Patro, Gopal Chandra
    Prusti, Jami Sagar
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2023, 17 (10) : AC1 - AC4
  • [9] Nerve Conduction Study in Healthy Elderly Subjects in Central India: A Cross-Sectional Study
    Taksande, Avinash B.
    Rawekar, Alka
    Kumar, Sunil
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (08)
  • [10] Association between vertebral cross-sectional area and lumbar disc displacement - a population-based study
    Ollila, Laura
    Oura, Petteri
    Karppinen, Jaro
    Niinimaki, Jaakko
    Junno, Juho-Antti
    EUROPEAN SPINE JOURNAL, 2024, 33 (03) : 900 - 905