Segmented spin-echo echo-planar imaging improves whole-brain BOLD functional MRI in awake pigeon brains

被引:1
|
作者
Khodadadi, Mina [1 ,2 ,5 ]
Helluy, Xavier [1 ,3 ]
Guentuerkuen, Onur [1 ,4 ]
Behroozi, Mehdi [1 ,5 ]
机构
[1] Ruhr Univ Bochum, Inst Cognit Neurosci, Fac Psychol, Dept Biopsychol, Bochum, Germany
[2] Univ Tehran, Fac Vet Med, Dept Basic Sci, Tehran, Iran
[3] Ruhr Univ Bochum, Fac Med, Dept Neurophysiol, Bochum, Germany
[4] Ruhr Univ Bochum, Res Ctr One Hlth Ruhr, Res Alliance Ruhr, Bochum, Germany
[5] Ruhr Univ Bochum, Inst Cognit Neurosci, Fac Psychol, Dept Biopsychol, Univ Str 150, D-44780 Bochum, Germany
基金
欧洲研究理事会;
关键词
auditory network; distortion correction; Field-L; RARE; reversed encoding phase; SE-EPI; GRADIENT-ECHO; FMRI; CONTRAST; IMPLEMENTATION; SENSITIVITY; ACTIVATION;
D O I
10.1002/nbm.5034
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Functional magnetic resonance imaging (fMRI) in awake small animals such as pigeons or songbirds opens a new window into the neural fundaments of cognitive behavior. However, high-field fMRI in the avian brain is challenging due to strong local magnetic field inhomogeneities caused by air cavities in the skull. A spoiled gradient-echo fMRI sequence has already been used to map the auditory network in songbirds, but due to susceptibility artifacts only 50% of the whole brain could be recorded. Since whole-brain fMRI coverage is vital to reveal whole-brain networks, an MRI sequence that is less susceptible to these artifacts was required. This was recently achieved in various bird species by using a rapid acquisition with relaxation enhancement (RARE) sequence. Weak blood oxygen level-dependent (BOLD) sensitivity, low temporal resolution, and heat caused by the long train of RF refocusing pulses are the main limits of RARE fMRI at high magnetic fields. To go beyond some of these limitations, we here describe the implementation of a two-segmented spin-echo echo-planar imaging (SE-EPI). The proposed sequence covers the whole brain of awake pigeons. The sequence was applied to investigate the auditory network in awake pigeons and assessed the relative merits of this method in comparison with the single-shot RARE sequence. At the same imaging resolution but with a volume acquisition of 3 s versus 4 s for RARE, the two-segmented SE-EPI provided twice the strength of BOLD activity compared with the single-shot RARE sequence, while the image signal-to-noise ratio (SNR) and in particular the temporal SNR were very similar for the two sequences. In addition, the activation patterns in two-segmented SE-EPI data are more symmetric and larger than single-shot RARE results. Two-segmented SE-EPI represents a valid alternative to the RARE sequence in avian fMRI research since it yields more than twice the BOLD sensitivity per unit of time with much less energy deposition and better temporal resolution, particularly for event-related experiments. A two-segmented SE-EPI sequence improves the temporal resolution and sensitivity of BOLD fMRI compared with the traditional RARE sequence as a reference sequence for the avian brain. These improvements open new windows in avian research to go beyond the block-design experiments and investigate functional connectivity and higher order cognitive abilities.image
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Comparison of DWI Methods in the Pediatric Brain: PROPELLER Turbo Spin-Echo Imaging Versus Readout-Segmented Echo-Planar Imaging Versus Single-Shot Echo-Planar Imaging
    Kim, Tae-Hyung
    Baek, Moon-Young
    Park, Ji Eun
    Ryu, Young Jin
    Cheon, Jung-Eun
    Kim, In-One
    Choi, Young Hun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (06) : 1352 - 1358
  • [2] Diffusion-weighted imaging of the brain: comparison of stimulated- and spin-echo echo-planar sequences
    Heiland, S
    Dietrich, O
    Sartor, K
    NEURORADIOLOGY, 2001, 43 (06) : 442 - 447
  • [3] Diffusion-weighted imaging of the brain: comparison of stimulated- and spin-echo echo-planar sequences
    S. Heiland
    O. Dietrich
    K. Sartor
    Neuroradiology, 2001, 43 : 442 - 447
  • [4] A whole-brain multi-subject functional MR imaging comparison of EPI spin-echo, asymmetric spin-echo and gradient-echo sequences at 1.5 t
    Kiehl, KA
    Smith, AM
    Forster, BB
    MacKay, A
    Whittall, KP
    Liddle, PF
    RADIOLOGY, 1997, 205 : 1043 - 1043
  • [5] A tractography comparison between turboprop and spin-echo echo-planar diffusion tensor imaging
    Gui, Minzhi
    Peng, Huiling
    Carew, John D.
    Lesniak, Maciej S.
    Arfanakis, Konstantinos
    NEUROIMAGE, 2008, 42 (04) : 1451 - 1462
  • [6] Spinal cord functional MRI at 3 T: Gradient echo echo-planar imaging versus turbo spin echo
    Bouwman, C. J. C.
    Wilmink, J. T.
    Mess, W. H.
    Backes, W. H.
    NEUROIMAGE, 2008, 43 (02) : 288 - 296
  • [7] Spin-echo echo-planar MR imaging of hepatocellular carcinoma arising from chronic liver damage: comparison with turbo spin-echo imaging
    Abe, Y
    Yamashita, Y
    Tang, Y
    Namimoto, T
    Nakayama, Y
    Takahashi, M
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2000, 24 (01) : 43 - 48
  • [8] Multivendor implementation and comparison of volumetric whole-brain echo-planar MR spectroscopic imaging
    Sabati, Mohammad
    Sheriff, Sulaiman
    Gu, Meng
    Wei, Juan
    Zhu, Henry
    Barker, Peter B.
    Spielman, Daniel M.
    Alger, Jeffry R.
    Maudsley, Andrew A.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (05) : 1209 - 1220
  • [9] Whole-Brain Analysis of Amyotrophic Lateral Sclerosis by Using Echo-Planar Spectroscopic Imaging
    Verma, Gaurav
    Woo, John H.
    Chawla, Sanjeev
    Wang, Sumei
    Sheriff, Sulaiman
    Elman, Lauren B.
    McCluskey, Leo F.
    Grossman, Murray
    Melhem, Elias R.
    Maudsley, Andrew A.
    Poptani, Harish
    RADIOLOGY, 2013, 267 (03) : 851 - 857
  • [10] Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging
    Tomura, N
    Kato, K
    Takahashi, S
    Sashi, R
    Izumi, J
    Narita, K
    Watarai, J
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (02) : 65 - 72