HEMODYNAMIC ANALYSIS OF CARDIOMEMS: ADVERSE HEMODYNAMIC EFFECTS

被引:0
|
作者
Liu, Zhenhao [1 ]
Han, Jiangli [2 ]
Chen, Xing [1 ]
机构
[1] Beihang Univ, Beijing Adv Innovat Ctr Biomed Engn, Sch Engn Med, Beijing 100191, Peoples R China
[2] Peking Univ Third Hosp, Dept Cardiol, Beijing 100191, Peoples R China
来源
2023 IEEE 36TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, MEMS | 2023年
基金
中国国家自然科学基金;
关键词
CardioMEMS; hemodynamics; computational fluid dynamics; implantable sensor; endovascular sensor; WALL SHEAR-STRESS; ARTERIES;
D O I
10.1109/MEMS49605.2023.10052229
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
CardioMEMS is a renowned and representative MEMS sensor for medical uses, while its long-term safety after implantation is still unclear. This work has studied the hemodynamic changes caused by CardioMEMS sensors. Both simulation and experimental results have shown that the CardioMEMS sensor disturbs local hemodynamics of vasculature with strong correlation to the implantation angles, and have suggested that implantation of such a MEMS sensor could cause atherosclerosis. A streamlined profile is proposed to relieve the adverse effects. This study provides a design guideline for MEMS endovascular sensors with hemodynamic consideration, which is of clinical significance to medical devices.
引用
收藏
页码:1068 / 1071
页数:4
相关论文
共 50 条
  • [1] Hemodynamic monitoring with the CardioMEMS HF System
    Falls, Candice
    NURSE PRACTITIONER, 2021, 46 (03): : 46 - 50
  • [2] Adverse effects and hemodynamic effects of nifedipine as a tocolytic
    Spiesser-Robelet, L.
    Martin, B.
    Carceller, A. -M.
    Bussieres, J. -F.
    Touzin, K.
    Audibert, F.
    Lachance, C.
    Ferreira, E.
    JOURNAL DE GYNECOLOGIE OBSTETRIQUE ET BIOLOGIE DE LA REPRODUCTION, 2015, 44 (07): : 614 - 620
  • [3] The Effects of Timing in Measurement of Pulmonary Artery Diastolic Pressure with CardioMEMS Hemodynamic Monitoring
    Anuwatwom, Amornpol
    Sethi, Prince
    Thompson, Paul
    Jonsson, Orvar
    JOURNAL OF CARDIAC FAILURE, 2017, 23 (08) : S54 - S54
  • [4] Influence of temperature on hemodynamic changes in heart failure: a cardiomems pa monitoring analysis
    Andrea Carrete, A.
    Codina, P.
    Ruiz-Cueto, M.
    Santiago-Vacas, E.
    Borrellas, A.
    Camblor, A.
    Domingo, M.
    Vilalta, V.
    Pulido, A.
    Velayos, P.
    Rivas, C.
    Gonzalez, B.
    Crespo, E.
    Lupon, J.
    Bayes-Genis, A.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 75 - 75
  • [5] RISK FACTORS FOR ADVERSE HEMODYNAMIC EFFECTS WITH DEXMEDETOMIDINE
    Mahmoud, Ahmed
    Flynn, Jeremy
    Flannery, Alexander
    CRITICAL CARE MEDICINE, 2014, 42 (12)
  • [6] THE ADVERSE HEMODYNAMIC-EFFECTS OF LAPAROSCOPIC CHOLECYSTECTOMY
    MCLAUGHLIN, JG
    SCHEERES, DE
    DEAN, RJ
    BONNELL, BW
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1995, 9 (02): : 121 - 124
  • [7] NITROPRUSSIDE PREVENTS ADVERSE HEMODYNAMIC EFFECTS OF VASOPRESSIN
    GELMAN, S
    ERNST, EA
    ARCHIVES OF SURGERY, 1978, 113 (12) : 1465 - 1471
  • [8] Hemodynamic Optimization in Patients With a Durable Leftventricular Assisted Device with CardioMEMS
    Harada, R.
    Daniel, B.
    George, T.
    Bhattal, G.
    Alom, M.
    Kabra, N.
    Rawitscher, D.
    Afzal, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2023, 42 (04): : S358 - S358
  • [9] RISK FACTORS FOR THE DEVELOPMENT OF HEMODYNAMIC ADVERSE EFFECTS WITH DEXMEDETOMIDINE
    Mahmoud, Ahmed
    Flynn, Jeremy
    Flannery, Alexander
    CRITICAL CARE MEDICINE, 2015, 43 (12)
  • [10] ADVERSE HEMODYNAMIC-EFFECTS OF FLECAINIDE IN CONSCIOUS DOGS
    GUBNER, R
    LINDENFELD, J
    HORWITZ, LD
    CIRCULATION, 1985, 72 (04) : 18 - 18