Modified 3D Graphene for Sensing and Electrochemical Capacitor Applications

被引:0
|
作者
Joseph, Kavitha Mulackampilly [1 ]
Dangel, Gabrielle R. [2 ]
Shanov, Vesselin [1 ,3 ]
机构
[1] Univ Cincinnati, Dept Mech & Mat Engn, Cincinnati, OH 45221 USA
[2] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
[3] Univ Cincinnati, Dept Chem & Environm Engn, Cincinnati, OH 45221 USA
关键词
3D graphene; nitrogen-doping; defective; square wave anodic stripping voltammetry (SWASV); Electric Double Layer Capacitor (EDLC); N-DOPED GRAPHENE; ELECTRODES; GRAPHITE; FILMS;
D O I
10.3390/nano14010108
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Less defective, nitrogen-doped 3-dimensional graphene (N3DG) and defect-rich, nitrogen-doped 3-dimensional graphene (N3DG-D) were made by the thermal CVD (Chemical Vapor Deposition) process via varying the carbon precursors and synthesis temperature. These modified 3D graphene materials were compared with pristine 3-dimensional graphene (P3DG), which has fewer defects and no nitrogen in its structure. The different types of graphene obtained were characterized for morphological, structural, and compositional assessment through Scanning Electron Microscopy (SEM), Raman Spectroscopy, and X-ray Photoelectron Spectroscopy (XPS) techniques. Electrodes were fabricated, and electrochemical characterizations were conducted to evaluate the suitability of the three types of graphene for heavy metal sensing (lead) and Electric Double-Layer Capacitor (EDLC) applications. Initially, the various electrodes were treated with a mixture of 2.5 mM Ruhex (Ru (NH3)6Cl3 and 25 mM KCl to confirm that all the electrodes underwent a reversible and diffusion-controlled electrochemical process. Defect-rich graphene (N3DG-D) revealed the highest current density, followed by pristine (P3DG) and less-defect graphene (N3DG). Further, the three types of graphene were subjected to a sensing test by square wave anodic stripping voltammetry (SWASV) for lead detection. The obtained preliminary results showed that the N3DG material provided a great lead-sensing capability, detecting as little as 1 mu M of lead in a water solution. The suitability of the electrodes to be employed in an Electric Double-Layer Capacitor (EDLC) was also comparatively assessed. Electrochemical characterization using 1 M sodium sulfate electrolyte was conducted through cyclic voltammetry and galvanostatic charge-discharge studies. The voltammogram and the galvanostatic charge-discharge (GCD) curves of the three types of graphene confirmed their suitability to be used as EDLC. The N3DG electrode proved superior with a gravimetric capacitance of 6.1 mF/g, followed by P3DG and N3DG, exhibiting 1.74 mF/g and 0.32 mF/g, respectively, at a current density of 2 A/g.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Electrodes modified with 3D graphene composites: a review on methods for preparation, properties and sensing applications
    Baig, Nadeem
    Saleh, Tawfik A.
    [J]. MICROCHIMICA ACTA, 2018, 185 (06)
  • [2] Electrodes modified with 3D graphene composites: a review on methods for preparation, properties and sensing applications
    Nadeem Baig
    Tawfik A. Saleh
    [J]. Microchimica Acta, 2018, 185
  • [3] 3D Printed Graphene Electrodes Modified with Prussian Blue: Emerging Electrochemical Sensing Platform for Peroxide Detection
    Katic, Vera
    dos Santos, Pamyla L.
    dos Santos, Matheus F.
    Pires, Bruno M.
    Loureiro, Hugo C.
    Lima, Ana P.
    Queiroz, Julia C. M.
    Landers, Richard
    Munoz, Rodrigo A. A.
    Bonacin, Juliano A.
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (38) : 35068 - 35078
  • [4] 3D Graphene Foam as a Monolithic and Macroporous Carbon Electrode for Electrochemical Sensing
    Dong, Xiaochen
    Wang, Xuewan
    Wang, Lianhui
    Song, Hao
    Zhang, Hua
    Huang, Wei
    Chen, Peng
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2012, 4 (06) : 3129 - 3133
  • [5] Fabrication of 3D Graphene and 3D Graphene Oxide Devices for Sensing VOCs
    So Matsuyama
    Tomoaki Sugiyama
    Toshiyuki Ikoma
    Jeffrey S. Cross
    [J]. MRS Advances, 2016, 1 (19) : 1359 - 1364
  • [6] Fabrication of 3D Graphene and 3D Graphene Oxide Devices for Sensing VOCs
    Matsuyama, So
    Sugiyama, Tomoaki
    Ikoma, Toshiyuki
    Cross, Jeffrey S.
    [J]. MRS ADVANCES, 2016, 1 (19): : 1359 - 1364
  • [7] Chemically modified graphene and nitrogen-doped graphene: Electrochemical characterisation and sensing applications
    Prathish, Krishna P.
    Barsan, Madalina M.
    Geng, Dongsheng
    Sun, Xueliang
    Brett, Christopher M. A.
    [J]. ELECTROCHIMICA ACTA, 2013, 114 : 533 - 542
  • [8] Electrochemical Sensing of Paracetamol Using 3D Porous Laser Scribed Graphene Platform
    Berni, Achraf
    Lahcen, Abdellatif Ait
    Amine, Aziz
    [J]. ELECTROANALYSIS, 2023, 35 (04)
  • [9] High-performance Gas Sensing by Chemically Modified 3D Graphene Hydrogel
    Wu, Jin
    Tao, Kai
    Miao, Jianmin
    Norford, Leslie K.
    [J]. 7TH IEEE INTERNATIONAL NANOELECTRONICS CONFERENCE (INEC) 2016, 2016,
  • [10] Applications of graphene in electrochemical sensing and biosensing
    Bahadir, Elif Burcu
    Sezginturk, Mustafa Kemal